Investigation on using high-energy proton beam for total body irradiation (TBI)

被引:4
|
作者
Zhang, Miao [1 ]
Qin, Nan [2 ]
Jia, Xun [2 ]
Zou, Wei J. [1 ]
Khan, Atif [1 ]
Yue, Ning J. [1 ]
机构
[1] Rutgers State Univ, Canc Inst New Jersey, Robert Wood Johnson Univ Hosp, Dept Radiat Oncol, 195 Little Albany St, New Brunswick, NJ 08901 USA
[2] Univ Texas Southwestern Med Ctr, Div Med Phys & Engn, Dept Radiat Oncol, Dallas, TX USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2016年 / 17卷 / 05期
关键词
proton therapy; total body irradiation; Monte Carlo; CARLO DOSE CALCULATION; SIMULATION;
D O I
10.1120/jacmp.v17i5.6223
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This work investigated the possibility of using proton beam for total body irradiation (TBI). We hypothesized the broad-slow-rising entrance dose from a monoenergetic proton beam can deliver a uniform dose to patient with varied thickness. Comparing to photon-based TBI, it would not require any patient-specific compensator or beam spoiler. The hypothesis was first tested by simulating 250 MeV, 275 MeV, and 300 MeV protons irradiating a wedge-shaped water phantom in a paired opposing arrangement using Monte Carlo (MC) method. To allow +/- 7.5% dose variation, the maximum water equivalent thickness (WET) of a treatable patient separation was 29 cm for 250 MeV proton, and > 40 cm for 275 MeV and 300 MeV proton. The compared 6 MV photon can only treat patients with up to 15.5 cm water-equivalent separation. In the second step, we simulated the dose deposition from the same beams on a patient's whole-body CT scan. The maximum patient separation in WET was 23 cm. The calculated whole-body dose variations were +/- 8.9%, +/- 9.0%, +/- 9.6%, and +/- 14% for 250 MeV proton, 275 MeV proton, 300MeV proton, and 6 MV photon. At last, we tested the current machine capability to deliver a monoenergetic proton beam with a large uniform field. Experiments were performed on a compact double scattering single-gantry proton system. With its C-shaped gantry design, the source-to-surface distance (SSD) reached 7 m. The measured dose deposition curve had 22 cm relatively flat entrance region. The full width half maximum field size was measured 105 cm. The current scatter filter had to be redesigned to produce a uniform intensity at such treatment distance. In conclusion, this work demonstrated the possibility of using proton beam for TBI. The current commercially available proton machines would soon be ready for such task.
引用
收藏
页码:90 / 98
页数:9
相关论文
共 50 条
  • [21] High-energy proton irradiation effects on tunnelling MOS capacitors
    Fleta, C
    Campabadal, F
    Rafí, JM
    Lozano, M
    Ullán, M
    MICROELECTRONIC ENGINEERING, 2004, 72 (1-4) : 85 - 89
  • [22] PITUITARY IRRADIATION WITH HIGH-ENERGY PROTON BEAMS - PRELIMINARY REPORT
    TOBIAS, CA
    LAWRENCE, JH
    BORN, JL
    MCCOMBS, RK
    ROBERTS, JE
    ANGER, HO
    LOWBEER, BVA
    HUGGINS, CB
    CANCER RESEARCH, 1958, 18 (02) : 121 - &
  • [23] Irradiation effects on Ti and SUS-304 membranes caused by the transmission of high-energy proton beam
    Yamaguchi, S
    Nagata, S
    Takahiro, K
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, PTS 1 AND 2, 1999, 475 : 484 - 487
  • [24] Hypofractionated high-energy proton-beam irradiation is an alternative treatment for WHO grade I meningiomas
    Vlachogiannis, Pavlos
    Gudjonsson, Olafur
    Montelius, Anders
    Grusell, Erik
    Isacsson, Ulf
    Nilsson, Kristina
    Blomquist, Erik
    ACTA NEUROCHIRURGICA, 2017, 159 (12) : 2391 - 2400
  • [25] Hypofractionated high-energy proton-beam irradiation is an alternative treatment for WHO grade I meningiomas
    Pavlos Vlachogiannis
    Olafur Gudjonsson
    Anders Montelius
    Erik Grusell
    Ulf Isacsson
    Kristina Nilsson
    Erik Blomquist
    Acta Neurochirurgica, 2017, 159 : 2391 - 2400
  • [26] Bone markers after total body irradiation (TBI)
    Couto-Silva, Ana-Claudia
    Trivin, Christine
    Esperou, Helene
    Michon, Jean
    Baruchel, Andre
    Souberbielle, Jean-Claude
    Brauner, Raja
    HORMONE RESEARCH, 2008, 70 : 185 - 185
  • [27] Low Dose Rate Pediatric Total Body Irradiation (TBI) Using TrueBeam
    Knutson, N.
    Yaddanapudi, S.
    Li, H.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [28] Procedure for total body irradiation (TBI) with Helical Tomotherapy
    Ferrer, C.
    Huertas, C.
    Plaza, R.
    de la Monja, P.
    Minguez, C.
    Garcia, D.
    Aznar, A.
    Saez, M.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1597 - S1598
  • [29] Hardness Assurance for Proton Direct Ionization-Induced SEEs Using a High-Energy Proton Beam
    Dodds, N. A.
    Schwank, J. R.
    Shaneyfelt, M. R.
    Dodd, P. E.
    Doyle, B. L.
    Trinczek, M.
    Blackmore, E. W.
    Rodbell, K. P.
    Gordon, M. S.
    Reed, R. A.
    Pellish, J. A.
    Label, K. A.
    Marshall, P. W.
    Swanson, S. E.
    Vizkelethy, G.
    Van Deusen, S.
    Sexton, F. W.
    Martinez, M. J.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (06) : 2904 - 2914
  • [30] INVESTIGATION OF THE AG-SI INTERFACE FORMED UNDER SIMULTANEOUS IRRADIATION USING A HIGH-ENERGY ION-BEAM
    BUDINAVICIUS, J
    PRANEVICIUS, L
    TAMULEVICIUS, S
    MATERIALS SCIENCE AND ENGINEERING B-SOLID STATE MATERIALS FOR ADVANCED TECHNOLOGY, 1989, 2 (1-3): : 203 - 206