Diffusion Anisotropy in Fresh and Fixed Prostate Tissue Ex Vivo

被引:19
|
作者
Bourne, Roger M. [1 ]
Bongers, Andre [2 ]
Chatterjee, Aritrick [1 ]
Sved, Paul [1 ,3 ]
Watson, Geoffrey [4 ]
机构
[1] Univ Sydney, Sydney, NSW, Australia
[2] Univ New South Wales, Sydney, NSW, Australia
[3] Royal Prince Alfred Hosp, Sydney, NSW, Australia
[4] Royal Prince Alfred Hosp, Sydney, NSW, Australia
基金
英国医学研究理事会;
关键词
diffusion weighted imaging; diffusion tensor imaging; fractional anisotropy; prostate; MAGNETIC-RESONANCE; 3; T; MULTIPARAMETRIC MRI; GLEASON SCORE; DECAY CURVES; TENSOR MRI; CANCER; WATER; COEFFICIENTS; FEASIBILITY;
D O I
10.1002/mrm.25908
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate diffusion anisotropy in whole human prostate specimens Methods: Seven whole radical prostatectomy specimens were obtained with informed patient consent and institutional ethics approval. Diffusion tensor imaging was performed at 9.4 Tesla. Diffusion tensors were calculated from the native acquired data and after progressive downsampling Results: Fractional anisotropy (FA) decreased as voxel volume increased, and differed widely between prostates. Fixation decreased mean FA by similar to 0.05-0.08 at all voxel volumes but did not alter principle eigenvector orientation. In unfixed tissue high FA (>0.6) was found only in voxels of volume <0.5 mm(3), and then only in a small fraction of all voxels. At typical clinical voxel volumes (4-16 mm(3)) less than 50% of voxels had FA > 0.25. FA decreased at longer diffusion times (Delta = 60 or 80 ms compared with 20 ms), but only by similar to 0.02 at typical clinical voxel volume. Peripheral zone FA was significantly lower than transition zone FA in five of the seven prostates Conclusion: FA varies widely between prostates. The very small proportion of clinical size voxels with high FA suggests that in clinical DWI studies ADC based on three-direction measurements will be minimally affected by anisotropy. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:626 / 634
页数:9
相关论文
共 50 条
  • [21] Tissue NMR Ex Vivo
    Smith, Ian C. P.
    Bezabeh, Tedros
    eMagRes, 2007, 2007
  • [22] High-resolution diffusion-weighted MR of fresh and fixed cat spinal cords: Evaluation of diffusion coefficients and anisotropy
    Pattany, PM
    Puckett, WR
    Klose, KJ
    Quencer, RM
    Bunge, RP
    Kasuboski, L
    Weaver, RG
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1997, 18 (06) : 1049 - 1056
  • [23] Biexponential diffusion decay in formalin-fixed prostate tissue: Preliminary findings
    Bourne, Roger M.
    Kurniawan, Nyoman
    Cowin, Gary
    Stait-Gardner, Timothy
    Sved, Paul
    Watson, Geoffrey
    Chowdhury, Supriya
    Price, William S.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (03) : 954 - 959
  • [24] Biexponential diffusion decay in formalin-fixed prostate tissue: Preliminary findings
    Bourne, Roger M.
    Kurniawan, Nyoman
    Cowin, Gary
    Stait-Gardner, Timothy
    Sved, Paul
    Watson, Geoffrey
    Chowdhury, Supriya
    Price, William S.
    Magnetic Resonance in Medicine, 2012, 68 (03): : 954 - 959
  • [25] In vivo 3 T and ex vivo 7 T diffusion tensor imaging of prostate cancer: Correlation with histology
    Uribe, Carlos F.
    Jones, Edward C.
    Chang, Silvia D.
    Goldenberg, S. Larry
    Reinsberg, Stefan A.
    Kozlowski, Piotr
    MAGNETIC RESONANCE IMAGING, 2015, 33 (05) : 577 - 583
  • [26] An Ex Vivo Prostate Gland Model
    不详
    ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 2010, 38 (06): : 443 - 443
  • [27] Ex Vivo Prostate Cancer Model
    不详
    ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 2019, 47 (01): : 5 - 6
  • [28] Measurements of T1-relaxation in ex vivo prostate tissue at 132 μT
    Busch, Sarah
    Hatridge, Michael
    Moessle, Michael
    Myers, Whittier
    Wong, Travis
    Mueck, Michael
    Chew, Kevin
    Kuchinsky, Kyle
    Simko, Jeffry
    Clarke, John
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (04) : 1138 - 1145
  • [29] INITIAL ASSESSMENT OF BOILING HISTOTRIPSY FOR MECHANICAL ABLATION OF EX VIVO HUMAN PROSTATE TISSUE
    Khokhlova, Vera A.
    Rosnitskiy, Pavel B.
    Tsysar, Sergey A.
    Buravkov, Sergey, V
    Ponomarchuk, Ekaterina M.
    Sapozhnikov, Oleg A.
    Karzova, Maria M.
    Khokhlova, Tatiana D.
    Maxwell, Adam D.
    Wang, Yak-Nam
    Kadrev, Alexey, V
    Chernyaev, Andrey L.
    Chernikov, Valery P.
    Okhobotov, Dmitriy A.
    Kamalov, Armais A.
    Schade, George R.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (01): : 62 - 71
  • [30] Ex Vivo MRI Evaluation of Prostate Cancer: Localization and Margin Status Prediction of Prostate Cancer in Fresh Radical Prostatectomy Specimens
    Heidkamp, Jan
    Hoogenboom, Martijn
    Kovacs, Iringo E.
    Veltien, Andor
    Maat, Arie
    Sedelaar, J. P. Michiel
    Hulsbergen-van de Kaa, Christina A.
    Futterer, Jurgen J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (02) : 439 - 448