Effects of machine errors on the ILC main linac

被引:0
|
作者
Wang Dou [1 ]
Gao Jie [1 ]
机构
[1] CAS, Inst High Energy Phys, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
ILC; main linac; machine errors; EMITTANCE GROWTH;
D O I
10.1088/1674-1137/35/6/015
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
For a practical linac, the beam property is affected seriously by any machine imperfections. In this paper, the effects of several main errors in the ILC main linac, such as quadrupole misalignment, magnet strength error and cavity misalignment, were studied by a theoretical method. The tolerance for each error was also obtained. Comparison with the numerical simulation result is made and the agreement is quite good.
引用
收藏
页码:585 / 589
页数:5
相关论文
共 50 条
  • [41] Installing a Proton Therapy Machine Like a LINAC
    Winey, B.
    Sharp, G.
    Clasie, B.
    MEDICAL PHYSICS, 2018, 45 (06) : E268 - E268
  • [42] Different options for dispersion free steering in the CLIC main linac
    Scbulte, D
    2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 2188 - 2190
  • [43] COMPARISON BETWEEN SMOOTH AND AG FOCUSING FOR THE CLIC MAIN LINAC
    HENKE, H
    TUCKMANTEL, J
    PROCEEDINGS OF THE 1989 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: ACCELERATOR SCIENCE AND TECHNOLOGY, 1989, : 848 - 850
  • [44] Failure Tolerant Operation and Trimming Principle in the CLIC Main Linac
    Siemaszko, Daniel
    Pittet, Serge
    PROCEEDINGS OF THE 2011-14TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE 2011), 2011,
  • [45] Main linac emittance growth and luminosity in future linear colliders
    Schulte, D
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 2727 - 2729
  • [46] Trajectory correction algorithms on the latest model of the CLIC main linac
    Fischer, C
    Parisi, G
    PROCEEEDINGS OF THE XVIII INTERNATIONAL LINEAR ACCELERATOR CONFERENCE, VOLS 1 AND 2, 1996, 96 (07): : 740 - 742
  • [47] Machining contour errors as ensembles of cutting, feeding and machine structure effects
    Cheng, YM
    Chin, JH
    INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 2003, 43 (10): : 1001 - 1014
  • [48] Sensitivity of Detecting MLC Positioning Errors for SBRT Treatment at Halcyon Linac
    Allen, J.
    Luo, W.
    Pokhrel, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E847 - E847
  • [49] Effects of linac wakefield on CSR microbunching in the Linac Coherent Light Source
    Huang, Z
    Borland, M
    Emma, P
    Kim, KJ
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 3138 - 3140
  • [50] Catching errors by synthetic CT in the clinical workflow of an MR-Linac
    Li, J.
    Tang, B.
    Liu, M.
    Guo, S.
    Yao, X.
    Liao, X.
    Feng, X.
    Orlandini, L. Clara
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1336 - S1337