V oxidation state in Fe-Ti oxides by high-energy resolution fluorescence-detected X-ray absorption spectroscopy

被引:66
|
作者
Bordage, Amelie [1 ,2 ]
Balan, Etienne [2 ]
de Villiers, Johan P. R. [3 ]
Cromarty, Robert [3 ]
Juhin, Amelie [2 ]
Carvallo, Claire [2 ]
Calas, Georges [2 ]
Raju, P. V. Sunder [4 ]
Glatzel, Pieter [5 ]
机构
[1] KFKI Res Inst Particle & Nucl Phys, H-1525 Budapest, Hungary
[2] Univ Paris 06, Univ Paris Diderot, CNRS,UMR 206,IRGP, Inst Mineral & Phys Milieux Condenses,UMR 7590,IR, F-75084 Paris 02, France
[3] Univ Pretoria, Dept Mat Sci & Met Engn, ZA-0002 Pretoria, South Africa
[4] Natl Geophys Res Inst, Council Sci & Ind Res, Hyderabad 500007, Andhra Pradesh, India
[5] European Synchrotron Radiat Facil, F-38043 Grenoble, France
关键词
Vanadium; Impurity; Oxidation state; V K edge HERFD-XAS; Fe-Ti oxides; COMPARATIVE PLANETARY MINERALOGY; K-EDGE; BUSHVELD COMPLEX; UPPER ZONE; 1ST-PRINCIPLES CALCULATIONS; ELECTRONIC-STRUCTURE; LOCAL ENVIRONMENT; VANADIUM VALENCE; BASALTIC GLASSES; OXYGEN FUGACITY;
D O I
10.1007/s00269-011-0418-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The oxidation state of vanadium in natural and synthetic Fe-Ti oxides is determined using high-energy resolution fluorescence-detected X-ray absorption spectroscopy (HERFD-XAS). Eleven natural magnetite-bearing samples from a borehole of the Main Magnetite Layer of the Bushveld Complex (South Africa), five synthetic Fe oxide samples, and three natural hematite-bearing samples from Dharwar supergroup (India) are investigated. V K edge spectra were recorded on the ID26 beamline at the European Synchrotron Radiation Facility (Grenoble, France), and the pre-edge features were used to determine the local environment and oxidation state of vanadium. In the case of the magnetite samples (natural and synthetic), we show that vanadium is incorporated in the octahedral site of the spinel structure under two oxidation states: +III and +IV. The variations of the pre-edge area are interpreted as various proportions in V3+ and V4+ (between 9.5 and 16.3% of V4+), V3+ being the main oxidation state. In particular, the variations of the V4+/V3+ ratio along the profile of the Main Magnetite Layer seem to follow the crystallization sequence of the layer. In the case of the hematite samples from India, the pre-edge features indicate that vanadium is substituted to Fe and mainly incorporated as V4+ (between 40 and 72% of V4+). We also demonstrate the potentiality of HERFD-XAS for mineralogical studies, since it can filter out the unwanted fluorescence and give better resolved spectra than conventional XAS.
引用
收藏
页码:449 / 458
页数:10
相关论文
共 50 条
  • [41] High energy resolution fluorescence detection x-ray absorption spectroscopy: Detection of adsorption sites in supported metal catalysts
    Tromp, Moniek
    van Bokhoven, Jeroen A.
    Safonova, Olga V.
    De Groot, Frank M. F.
    Evans, John
    Glatzel, Pieter
    X-RAY ABSORPTION FINE STRUCTURE-XAFS13, 2007, 882 : 651 - +
  • [42] High-resolution spectroscopy on an X-ray absorption beamline
    Hazemann, Jean-Louis
    Proux, Olivier
    Nassif, Vivian
    Palancher, Herve
    Lahera, Eric
    Da Silva, Cecile
    Braillard, Aurelien
    Testemale, Denis
    Diot, Marie-Ange
    Alliot, Isabelle
    Del Net, William
    Manceau, Alain
    Gelebart, Frederic
    Morand, Marc
    Dermigny, Quentin
    Shukla, Abhay
    JOURNAL OF SYNCHROTRON RADIATION, 2009, 16 : 283 - 292
  • [43] In-situ high-energy-resolution X-ray absorption spectroscopy for UO2 oxidation at SSRF
    Pei-Quan Duan
    Hong-Liang Bao
    Jiong Li
    Han-Jie Cao
    Yu-Ying Huang
    NuclearScienceandTechniques, 2017, 28 (01) : 3 - 6
  • [44] In-situ high-energy-resolution X-ray absorption spectroscopy for UO2 oxidation at SSRF
    Duan, Pei-Quan
    Bao, Hong-Liang
    Li, Jiong
    Cao, Han-Jie
    Huang, Yu-Ying
    NUCLEAR SCIENCE AND TECHNIQUES, 2017, 28 (01)
  • [45] In-situ high-energy-resolution X-ray absorption spectroscopy for UO2 oxidation at SSRF
    Pei-Quan Duan
    Hong-Liang Bao
    Jiong Li
    Han-Jie Cao
    Yu-Ying Huang
    Nuclear Science and Techniques, 2017, 28
  • [46] High resolution x-ray absorption spectroscopy with absolute energy Calibration for the determination of absorption edge energies
    Kraft, S
    Stumpel, J
    Becker, P
    Kuetgens, U
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (03): : 681 - 687
  • [47] Development of high-energy and high-resolution X-ray CT
    Sato, Katsutoshi
    Abe, Makoto
    Takatsuji, Toshiyuki
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2018, 54 : 276 - 283
  • [48] High-resolution x-ray spectrometer for x-ray absorption fine structure spectroscopy
    Chin, D. A.
    Nilson, P. M.
    Mastrosimone, D.
    Guy, D.
    Ruby, J. J.
    Bishel, D. T.
    Seely, J. F.
    Coppari, F.
    Ping, Y.
    Rygg, J. R.
    Collins, G. W.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (01):
  • [49] Chemical analysis of ternary Ti oxides using soft X-ray absorption spectroscopy
    Soriano, L
    Abbate, M
    Fernandez, A
    GonzalezElipe, AR
    Sanz, JM
    SURFACE AND INTERFACE ANALYSIS, 1997, 25 (10) : 804 - 808
  • [50] High-resolution X-ray fluorescence and excitation spectroscopy of metalloproteins
    Wang, X
    Grush, MM
    Froeschner, AG
    Cramer, SP
    JOURNAL OF SYNCHROTRON RADIATION, 1997, 4 : 236 - 242