Effect of frameless stereotaxy on the accuracy of C1-2 transarticular screw placement

被引:87
|
作者
Bloch, O
Holly, LT
Park, J
Obasi, C
Kim, K
Johnson, JP
机构
[1] Cedars Sinai Inst Spinal Disorders, Los Angeles, CA 90048 USA
[2] Univ Calif Los Angeles, Med Ctr, Los Angeles, CA 90024 USA
[3] Univ Washington, Seattle, WA 98195 USA
[4] Arrowhead Reg Med Ctr, San Bernardino, CA USA
[5] Univ Calif Davis, Med Ctr, Sacramento, CA 95817 USA
关键词
screw fixation; frameless stereotaxy; cervical spine;
D O I
10.3171/spi.2001.95.1.0074
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. In recent studies some authors have indicated that 20% of patients have at least one ectatic vertebral artery (VA) that, based on previous criteria in which preoperative computerized tomography (CT) and standard intraoperative fluoroscopic techniques were used, may prevent the safe placement of C1-2 transarticular screws. The authors conducted this study to determine whether frameless stereotaxy would improve the accuracy of C1-2 transarticular screw placement in healthy patients, particularly those whom previous criteria would have excluded. Methods. The authors assessed the accuracy of frameless stereotaxy for C1-2 transarticular screw placement in 17 cadaveric cervical spines. Preoperatively obtained CT scans of the C-2 vertebra were registered on a stereotactic workstation. The dimensions of the C-2 pars articularis were measured on the workstation, and a 3.5-mm screw was stereotactically placed if the height and width of the pars interarticularis was greater than 4 mm. The specimens were evaluated with postoperative CT scanning and visual inspection. Screw placement was considered acceptable if the screw was contained within the C-2 pars interarticularis, traversed the C1-2 joint, and the screw tip was shown to be within the anterior cortex of the C-l lateral mass. Transarticular screws were accurately placed in 16 cadaveric specimens, and only one specimen (5.9%) was excluded because of anomalous VA anatomy. In contrast, a total of four specimens (23.5%) showed significant narrowing of the C-2 pars interarticularis due to vascular anatomy that would have precluded atlantoaxial transarticular screw placement had previous nonimage-guided criteria been used. Conclusions. Frameless stereotaxy provides precise image guidance that improves the safety of C1-2 transarticular screw placement and potentially allows this procedure to be performed in patients previously excluded because of the inaccuracy of nonimage-guided techniques.
引用
收藏
页码:74 / 79
页数:6
相关论文
共 50 条
  • [41] Deviation Analysis of C1-C2 Transarticular Screw Placement Assisted by a Novel Rapid Prototyping Drill Template A Cadaveric Study
    Hu, Yong
    Yuan, Zhen-Shan
    Kepler, Christopher K.
    Albert, Todd J.
    Yuan, Jian-Bing
    Dong, Wei-Xin
    Sun, Xiao-Yang
    Wang, Cheng-Tao
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2014, 27 (05): : E181 - E186
  • [42] Posterior C1-2 fusion with C1 lateral mass and C2 isthmic screws: accuracy of screw position, alignment and patient outcome
    Florian Ringel
    Andreas Reinke
    Carsten Stüer
    Bernhard Meyer
    Michael Stoffel
    Acta Neurochirurgica, 2012, 154 : 305 - 312
  • [43] Posterior C1-2 fusion with C1 lateral mass and C2 isthmic screws: accuracy of screw position, alignment and patient outcome
    Ringel, Florian
    Reinke, Andreas
    Stueer, Carsten
    Meyer, Bernhard
    Stoffel, Michael
    ACTA NEUROCHIRURGICA, 2012, 154 (02) : 305 - 312
  • [44] Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis - Comment
    McCormick, PC
    NEUROSURGERY, 1998, 43 (02) : 280 - 280
  • [45] Biomechanical Study of Horizontal Screw-screw Crosslink in C1-2 Pedicle Screw-rod Fixation
    Ouyang, Beiping
    Zou, Xiaobao
    Luo, Chunshan
    Lu, Tingsheng
    Ma, Xiangyang
    CLINICAL SPINE SURGERY, 2023, 36 (10): : E519 - E523
  • [46] Results of C1-C2 transarticular screw fixation in a series of 20 patients
    Arráez, MA
    NEUROCIRUGIA, 2002, 13 (06): : 436 - 436
  • [47] Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis - Reply
    Dickman, CA
    Sonntag, VKH
    NEUROSURGERY, 1999, 44 (03) : 688 - 689
  • [48] Aggregatibacter aphrophilus ventriculitis following C1-C2 transarticular screw fixation
    Tok, Sina
    Neidert, Marian Christoph
    Bloemberg, Guido
    Sueruecue, Oguzkan
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2016, 50 (01) : 63 - 68
  • [49] Biomechanical Assessment of Bilateral C1 Laminar Hook and C1-2 Transarticular Screws and Bone Graft for Atlantoaxial Instability
    Guo, Xiang
    Ni, Bin
    Zhao, Weidong
    Wang, Mingfei
    Zhou, Fengjin
    Li, Songkai
    Ren, Zhongwu
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2009, 22 (08): : 578 - 585
  • [50] Modification of C1-C2 transarticular screw fixation by image-guided surgery
    Weidner, A
    Wähler, M
    Chiu, ST
    Ullrich, CG
    SPINE, 2000, 25 (20) : 2668 - 2673