Effect of shoulder angle variation on sEMG-based elbow joint angle estimation

被引:3
|
作者
Tang, Zhichuan [1 ,2 ]
Yang, Hongchun [1 ]
Zhang, Lekai [1 ]
Liu, Pengcheng [3 ]
机构
[1] Zhejiang Univ Technol, Ind Design Inst, Hangzhou 310014, Zhejiang, Peoples R China
[2] Zhejiang Univ, Modern Ind Design Inst, Hangzhou 310027, Zhejiang, Peoples R China
[3] Univ Lincoln, Lincoln Ctr Autonomous Syst, Lincoln LN5 7DH, England
基金
中国国家自然科学基金;
关键词
Shoulder angle; Electromyogram; Elbow angle; Estimation; UPPER-LIMB PROSTHESES; MYOELECTRIC CONTROL; SURFACE EMG; PATTERN-RECOGNITION; ARM POSITION; EXOSKELETON; FORCE; PERFORMANCE; DISCOMFORT; FREQUENCY;
D O I
10.1016/j.ergon.2018.08.012
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
For the decade now, surface electromyogram (sEMG) signal has been extensively applied in joint angle estimation to control the prostheses and exoskeleton systems. However, the sEMG signal patterns can be severely affected by shoulder angle variations, which restricts its applications to a practical use. In our study, we evaluate the effect of shoulder angle variations on elbow angle estimation performance. This adverse effect increases mean root mean square (RMS) error by 14.85 degrees in our experiment. Then, four estimation methods are proposed to solve this problem: (1) using a training set including all shoulder angles' training data to train model; (2) adding two shoulder muscles' sEMG as additional inputs; (3) a two-step method using arm muscles' sEMG and two shoulder muscles' sEMG; and (4) a two-step method using arm muscles' sEMG and measured shoulder angle value by a motion sensor. 13 subjects are employed in this study. The experimental results demonstrate that the mean RMS error is reduced from 21.36 degrees to 12.85 degrees in method one, 9.84 degrees in method two, 7.67 degrees in method three, and 6.93 degrees in method four, respectively. These results show that our methods are effective to eliminate the adverse effect of shoulder angle variations and achieve a better elbow angle estimation performance. Furthermore, this study is helpful to develop a natural and stable control system for prostheses and exoskeleton systems.
引用
收藏
页码:280 / 289
页数:10
相关论文
共 50 条
  • [21] Adaptive threshold to compensate the effect of muscle fatigue on elbow-joint angle estimation based on electromyography
    Triwiyanto
    Wahyunggoro, O.
    Nugroho, H. A.
    Herianto
    JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES, 2018, 12 (03) : 3786 - 3796
  • [22] Elbow Joint Angle Estimation by Using Integrated Surface Electromyography
    Mamikoglu, U.
    Nikolakopoulos, G.
    Pauelsen, M.
    Varagnolo, D.
    Roijezon, U.
    Gustafsson, T.
    2016 24TH MEDITERRANEAN CONFERENCE ON CONTROL AND AUTOMATION (MED), 2016, : 785 - 790
  • [23] Effect of elbow joint angle on the magnitude of muscle damage to the elbow flexors
    Nosaka, K
    Sakamoto, K
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (01): : 22 - 29
  • [24] Elements Influencing sEMG-Based Gesture Decoding: Muscle Fatigue, Forearm Angle and Acquisition Time
    Qing, Zengyu
    Lu, Zongxing
    Cai, Yingjie
    Wang, Jing
    SENSORS, 2021, 21 (22)
  • [25] Transhumeral Prosthesis Prototype with 3D Printing and sEMG-based Elbow Joint Control Method
    Sittiwanchai, Teppakorn
    Nakayama, Ippei
    Inoue, Shinichi
    Kobayashi, Jun
    2014 INTERNATIONAL CONFERENCE ON ADVANCED MECHATRONIC SYSTEMS (ICAMECHS), 2014, : 227 - 231
  • [26] EXAMINATION OF ELBOW ARTICULATION, WITH PARTICULAR REFERENCE TO VARIATION OF CARRYING ANGLE, AND ITS EFFECT ON JOINT REPLACEMENTS
    DOWSON, D
    UNSWORTH, A
    MILLER, JH
    WRIGHT, V
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1977, 59 (02): : 247 - 247
  • [27] Human elbow joint angle estimation using electromyogram signal processing
    Yu, H. -J.
    Lee, A. Y.
    Choi, Y.
    IET SIGNAL PROCESSING, 2011, 5 (08) : 767 - 775
  • [28] A Fast Calibration Method for an sEMG-Based Lower Limb Joint Torque Estimation Model
    Zhang, Yuepeng
    Ling, Ziqin
    Cao, Guangzhong
    Li, Linglong
    Diao, Dongfeng
    Cui, Fang
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 93
  • [29] Estimation of elbow joint angle by NARX model using EMG data
    Ehrampoosh, Armin
    Yousefi-koma, Aghil
    Ayati, Moosa
    2015 3RD RSI INTERNATIONAL CONFERENCE ON ROBOTICS AND MECHATRONICS (ICROM), 2015, : 444 - 448
  • [30] Elbow Joint Angle Estimation with Surface Electromyography Using Autoregressive Models
    Sommer, L. F.
    Barreira, C.
    Noriega, C.
    Camargo-Junior, F.
    Moura, R. T.
    Forner-Cordero, A.
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 1472 - 1475