Experimental investigation of PEM fuel cells for a m-CHP system with membrane reformer

被引:11
|
作者
Foresti, S. [1 ]
Manzolini, G. [1 ]
Escribano, S. [2 ,3 ]
机构
[1] Politecn Milan, Dipartimento Energia, Via Lambruschini 4, I-20156 Milan, Italy
[2] CEA LITEN DEHT, 17 Rue Martyrs, F-38054 Grenoble 9, France
[3] Univ Grenoble Alpes, F-38000 Grenoble, France
关键词
Micro-cogeneration; Polymeric electrolyte membrane; fuel cell; Hydrogen dilution; CO poisoning; Current density distribution; DEAD-ENDED ANODE; HYDROGEN CROSSOVER; NITROGEN CROSSOVER; PURGE CYCLE; OPTIMIZATION; PERFORMANCE; OPERATION; CO2; RECIRCULATION; DESIGN;
D O I
10.1016/j.ijhydene.2017.08.046
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
An innovative small-scale cogeneration system based on membrane reformer and PEM fuel cells is under development within the FIuidCELL project. An experimental campaign has been carried out to characterize the PEM fuel cell and to define the operative conditions when integrated within the system. The hydrogen feeding the PEM is produced by a membrane reactor which in principle can separate pure hydrogen; however, in general, hydrogen purity is around 99.9%-99.99%. The focus of this work is the assessment of the PEM performance under different hydrogen purities featuring actual membrane selectivity and gases build-up by anode off-gas recirculation. Their effects on the cells voltage and local current distribution are measured at different conditions (pressure, humidity, stoichiometry, with and without air bleeding, in flow-through and dead-end operation). In flow-through mode, the cell voltage is relatively insensitive to the presence of inert gases (e.g. -20 mV with inerts/H-2 from 0 to 20.10(-2) at 0.3 A/cm(2)), and resistant also to CO (e.g. -35 mV with inerts/H-2 = 20.10(-2) and CO/H-2 from 0 to 20.10(-6) at 0.3 A/cm(2)), thanks to the Ru presence in the anode catalyst. Looking at the current density distribution on the cell surface, the most critical areas are the cathode inlet, likely due to insufficient air humidification, and the anode outlet, because of low hydrogen concentration and CO poisoning of the catalyst. Dead-end operation is also investigated using humid or impure hydrogen. In this case relatively small amount of impurities in the hydrogen feed rapidly reduces the cell voltage, requiring frequent purges (e.g. every 30 s with inerts/H-2 = 0.5.10(-2) at 0.3 A/ cm(2)). These experiments set the basis for the management of the PEMFC stack integrated into the m-CHP system based on the FluidCELL concept. (C) 2017 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:25334 / 25350
页数:17
相关论文
共 50 条
  • [31] Assembly pressure and membrane swelling in PEM fuel cells
    Zhou, Y.
    Lin, G.
    Shih, A. J.
    Hu, S. J.
    JOURNAL OF POWER SOURCES, 2009, 192 (02) : 544 - 551
  • [32] Experimental Investigation of Cathode Backpressure Effect on Voltage Oscillations in a PEM Fuel Cell System
    Andronie, Adriana
    Stamatin, Ioan
    Girleanu, Valentin
    Ionescu, Viorel
    ADVANCED TOPICS IN OPTOELECTRONICS, MICROELECTRONICS, AND NANOTECHNOLOGIES IX, 2018, 10977
  • [33] An energetic-exergetic analysis of a residential CHP system based on PEM fuel cell
    Barelli, L.
    Bidini, G.
    Gallorini, F.
    Ottaviano, A.
    APPLIED ENERGY, 2011, 88 (12) : 4334 - 4342
  • [34] A dynamic model of a shipboard PEM fuel cell reformer system with an integrated gas turbine
    Miller, Steven P.
    Heinzel, John M.
    Kuseian, John H.
    Hoffman, Donald J.
    House, Edward M.
    Nickens, Anthony
    Tsourapas, Vasilis
    Proceedings of the ASME Turbo Expo 2006, Vol 5, Pts A and B, 2006, : 77 - 84
  • [35] CFD simulation of Pd-based membrane reformer when thermally coupled within a fuel cell micro-CHP system
    Politecnico di Milano, Dipartimento di Energia, Via Lambruschini 4, 20156 Milano, Italy
    Int J Hydrogen Energy, 1600, 22 (12668-12679):
  • [36] Experimental device for measuring fuel cell PEM membrane degradation
    Dejmek, Jiri
    PRZEGLAD ELEKTROTECHNICZNY, 2009, 85 (04): : 7 - 9
  • [37] Dynamic modeling of an integrated reformer membrane fuel cell system
    Pravin, P. S.
    Gudi, Ravindra D.
    Bhartiya, Sharad
    IFAC PAPERSONLINE, 2017, 50 (01): : 10790 - 10795
  • [38] Experimental investigation of exergy losses of a PEM fuel cell system Experimentelle Untersuchung der Exergieverluste eines PEM Brennstoffzellensystems
    Ch. Na Ranong
    J. Hapke
    G. Fieg
    Forschung im Ingenieurwesen, 2009, 73 (4) : 193 - 203
  • [39] Experimental study on performance of membrane humidifiers with different configurations and operating conditions for PEM fuel cells
    Houreh, N. Baharlou
    Ghaedamini, M.
    Shokouhmand, H.
    Afshari, E.
    Ahmaditaba, A. H.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2020, 45 (07) : 4841 - 4859
  • [40] Experimental investigation on the performance of proton exchange membrane fuel cell (PEM) for high power and water management
    Ous, T.
    Nouri, J. M.
    Gavaises, M.
    Arcoumanis, C.
    SECOND INTERNATIONAL CONFERENCE ON OPTICAL AND LASER DIAGNOSTICS, 2006, 45 : 214 - 214