Experimental investigation of PEM fuel cells for a m-CHP system with membrane reformer

被引:11
|
作者
Foresti, S. [1 ]
Manzolini, G. [1 ]
Escribano, S. [2 ,3 ]
机构
[1] Politecn Milan, Dipartimento Energia, Via Lambruschini 4, I-20156 Milan, Italy
[2] CEA LITEN DEHT, 17 Rue Martyrs, F-38054 Grenoble 9, France
[3] Univ Grenoble Alpes, F-38000 Grenoble, France
关键词
Micro-cogeneration; Polymeric electrolyte membrane; fuel cell; Hydrogen dilution; CO poisoning; Current density distribution; DEAD-ENDED ANODE; HYDROGEN CROSSOVER; NITROGEN CROSSOVER; PURGE CYCLE; OPTIMIZATION; PERFORMANCE; OPERATION; CO2; RECIRCULATION; DESIGN;
D O I
10.1016/j.ijhydene.2017.08.046
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
An innovative small-scale cogeneration system based on membrane reformer and PEM fuel cells is under development within the FIuidCELL project. An experimental campaign has been carried out to characterize the PEM fuel cell and to define the operative conditions when integrated within the system. The hydrogen feeding the PEM is produced by a membrane reactor which in principle can separate pure hydrogen; however, in general, hydrogen purity is around 99.9%-99.99%. The focus of this work is the assessment of the PEM performance under different hydrogen purities featuring actual membrane selectivity and gases build-up by anode off-gas recirculation. Their effects on the cells voltage and local current distribution are measured at different conditions (pressure, humidity, stoichiometry, with and without air bleeding, in flow-through and dead-end operation). In flow-through mode, the cell voltage is relatively insensitive to the presence of inert gases (e.g. -20 mV with inerts/H-2 from 0 to 20.10(-2) at 0.3 A/cm(2)), and resistant also to CO (e.g. -35 mV with inerts/H-2 = 20.10(-2) and CO/H-2 from 0 to 20.10(-6) at 0.3 A/cm(2)), thanks to the Ru presence in the anode catalyst. Looking at the current density distribution on the cell surface, the most critical areas are the cathode inlet, likely due to insufficient air humidification, and the anode outlet, because of low hydrogen concentration and CO poisoning of the catalyst. Dead-end operation is also investigated using humid or impure hydrogen. In this case relatively small amount of impurities in the hydrogen feed rapidly reduces the cell voltage, requiring frequent purges (e.g. every 30 s with inerts/H-2 = 0.5.10(-2) at 0.3 A/ cm(2)). These experiments set the basis for the management of the PEMFC stack integrated into the m-CHP system based on the FluidCELL concept. (C) 2017 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:25334 / 25350
页数:17
相关论文
共 50 条
  • [1] Advanced m-CHP fuel cell system based on a novel bio-ethanol fluidized bed membrane reformer
    Luis Viviente, Jose
    Melendez, Jon
    Pacheco Tanaka, David Alfredo
    Gallucci, Fausto
    Spallina, Vincenzo
    Manzolini, Giampaolo
    Foresti, Stefano
    Palma, Vincenzo
    Ruocco, Concetta
    Roses, Leonardo
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (19) : 13970 - 13987
  • [2] Residential m-CHP system
    不详
    AMERICAN CERAMIC SOCIETY BULLETIN, 2007, 86 (03): : A34 - A34
  • [3] m-CHP system development for German market
    不详
    AMERICAN CERAMIC SOCIETY BULLETIN, 2007, 86 (05): : 35 - 36
  • [4] DEVELOPMENT OF A MEDIUM-SIZE STEAM REFORMER FOR CHP APPLICATIONS BASED ON PEM FUEL CELLS
    Pisani, Giovanni
    Zerbinato, Alberto
    Tregambe, Carlo
    Benini, Ernesto
    PROCEEDINGS OF THE ASME TURBO EXPO 2010, VOL 3, 2010, : 945 - 952
  • [5] Demonstration of a residential CHP system based on PEM fuel cells
    Gigliucci, G
    Petruzzi, L
    Cerelli, E
    Garzisi, A
    La Mendola, A
    JOURNAL OF POWER SOURCES, 2004, 131 (1-2) : 62 - 68
  • [6] Micromachined methanol reformer for portable PEM fuel cells
    Kim, Taegyu
    Lee, Dae Hoon
    Park, Dae-Eun
    Kwon, Sejin
    JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 2008, 5 (01):
  • [7] Numerical and experimental investigation of electrical efficiency improvement of a micro combined heat and power (M-chp) system by modifying cam curve of ohvg engine
    Goodarzvand-Chegini F.
    Habibi M.
    Rakhsha S.
    Samiee L.
    Amini M.
    Jaafari J.
    Barati A.
    Recent Innovations in Chemical Engineering, 2020, 13 (03) : 203 - 222
  • [8] High temperature PEM fuel cell integrated with a cellular membrane methanol steam reformer: Experimental and modelling
    Ribeirinha, P.
    Abdollahzadeh, M.
    Pereira, A.
    Relvas, F.
    Boaventura, M.
    Mendes, A.
    APPLIED ENERGY, 2018, 215 : 659 - 669
  • [9] Experimental investigation and mathematical modeling of triode PEM fuel cells
    Martino, E.
    Koilias, G.
    Athanasiou, M.
    Katsaounis, A.
    Dimakopoulos, Y.
    Tsamopoulos, J.
    Vayenas, C. G.
    ELECTROCHIMICA ACTA, 2017, 248 : 518 - 533
  • [10] Integration of high temperature PEM fuel cells with a methanol reformer
    Pan, C
    He, RH
    Li, QF
    Jensen, JO
    Bjerrum, NJ
    Hjulmand, HA
    Jensen, AB
    JOURNAL OF POWER SOURCES, 2005, 145 (02) : 392 - 398