Pseudophase microextraction for in-line sample concentration in micellar electrokinetic chromatography

被引:12
|
作者
Yu, Raymond B. [1 ,2 ]
Quirino, Joselito P. [1 ]
机构
[1] Univ Tasmania, Australian Ctr Res Separat Sci, Sch Nat Sci Chem, Hobart, Tas 7001, Australia
[2] Univ Philippines, Dept Pharmaceut Chem, Coll Pharm, Manila, Philippines
基金
澳大利亚研究理事会;
关键词
Capillary electrophoresis; In-line sample concentration; Micellar electrokinetic chromatography; Pseudophase extraction; Sweeping; LIQUID-LIQUID MICROEXTRACTION; CAPILLARY-ELECTROPHORESIS; PRECONCENTRATION; EXTRACTION; HERBICIDES; WATERS;
D O I
10.1016/j.aca.2021.339219
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pseudophase microextraction (PPME) as a simple in-line sample concentration technique in micellar electrokinetic chromatography (MEKC) is presented. In contrast to popular electric-field driven stacking techniques in MEKC such as sweeping, PPME is pressure-driven. The technique afforded up to 403-296 8x improvements in peak heights for fenoprop, dichlorprop, 1- and 2-naphthol compared to typical injection. Under the same MEKC conditions, the improvements in PPME were up to 23-59x better compared to sweeping. Briefly in PPME, the entire capillary was loaded (up to 20 capillary volumes) with the sample prepared in a dilute solution of cetyltrimethylammonium bromide ([CTAB] critical surface aggregation concentration). The CTAB formed aggregates at the inner capillary walls and these aggregates acted as a stationary chromatographic pseudophase. After clean-up via flushing the capillary with purified water, the MEKC background solution (BGS) with sodium dodecyl sulfate was then introduced by pressure from the outlet end to elute the retained analytes. The analytes concentrate at front of the BGS and the front was moved to the inlet end of the capillary prior to MEKC. Optimization strategies and current limitations in PPME-MEKC are described. The linear ranges using a 4 capillary volume sample load obtained for fenoprop, dichlorprop, 1- and 2-naphthol were between 1 and 160 ng/mL (r(2)s > 0.996), LOQs = 1-2.5 ng/mL and repeatability %RSDs (n = 6) were <= 5% (intra-day) and <= 7% (inter-day) (using low analyte concentrations 1-5x LOQ). PPME-MEKC with simple dilution of fortified real samples (no offline sample concentration) was also able to detect low levels of dichlorprop (10 ng/mL, limit set in Australia) and 1- and 2-naphthol (7.5-15 ng/mL) in a drinking water and natural water sample, respectively (% recovery = 84-108%). The concept of PPME may find use in other modes of capillary electrophoresis and other nano-microscale separations. (C) 2021 Published by Elsevier B.V.
引用
收藏
页数:7
相关论文
共 50 条