Cerebral measurements made using cranial ultrasound in term Ugandan newborns

被引:15
|
作者
Hagmann, C. F. [1 ]
Robertson, N. J. [1 ]
Acolet, D. [2 ]
Nyombi, N. [3 ]
Ondo, S. [4 ]
Nakakeeto, M. [3 ]
Cowan, F. M. [4 ]
机构
[1] UCL, EGA UCL Inst Womens Hlth, London, England
[2] London Sch Hyg & Trop Med, Med Stat Unit, London WC1, England
[3] SBCU Mulago Hosp, Kampala, Uganda
[4] Univ London Imperial Coll Sci Technol & Med, Dept Paediat & Imaging Sci, Comprehens Biomed Res Ctr, London W12 OHS, England
关键词
Cerebral measurements; Term neonate; Cranial ultrasound; Normal; African; CAVUM-SEPTI-PELLUCIDI; NORMAL FETAL DEVELOPMENT; LOW-RESOURCE SETTINGS; SUBARACHNOID SPACE; CORPUS-CALLOSUM; LATERAL VENTRICLES; CEREBELLAR VERMIS; GESTATIONAL-AGE; PRETERM INFANTS; HIGH-RESOLUTION;
D O I
10.1016/j.earlhumdev.2011.01.044
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Background: Few cUS studies of cerebral measurements are available for normal term infants. Normative data is important for evaluating cerebral structure size in symptomatic term infants and assessing preterm brain growth by term age. Objectives: To (i) make linear measurements using cranial ultrasound (cUS) for major cerebral structures and intracranial spaces in normal newborn term infants, (ii) correlate these measurements with gestational age (GA), birth weight (BW), head circumference (HC), gender and within one infant (iii) examine inter/intra-observer variation, and (iv) compare these data with those currently available. Design, setting and patients: Linear cUS measurements of major cerebral structures were made in well termborn Ugandan infants at Mulago University Hospital, Kampala. Correlations between the measurements and gender, HC. BW and GA were calculated. Intra- and inter-observer agreements were assessed. Results: Data from 106 infants (mean GA 39.20 +/- 1.4SD weeks) were analysed. Intra/inter-observer agreement was substantial/excellent. Significant correlations were found between HC and pons anterior-posterior diameter (p<0.01), corpus callosal (CC) length (p=0.02) and transverse cerebellar diameter (TCD, p<0.01) and between BW and CC length (p=0.02), vermis height (<0.01) and thalamo-occipital distance (p=0.03); no significant correlation was found with GA. Within infants CC length and TCD correlated significantly (p=0.019). Males had larger left ventricular indices than females (p=0.04). The data was similar to those from other populations. Conclusions: These data provide reliable reference values for linear measurements of many cerebral structures made using cUS. The data agree well with those from other populations suggesting that cerebral size is similar in different ethnic groups. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:341 / 347
页数:7
相关论文
共 50 条
  • [31] Selective cerebral white matter injury in asphyxiated term newborns
    Landesman, B
    Poskitt, K
    Roland, EH
    Lupton, BA
    Hill, A
    ANNALS OF NEUROLOGY, 2003, 54 : S126 - S126
  • [32] Cranial ultrasound findings in preterm infants predict the development of cerebral palsy
    Skovgaard, Ann Lawaetz
    Zachariassen, Gitte
    DANISH MEDICAL JOURNAL, 2017, 64 (02):
  • [33] USEFULNESS OF CRANIAL ULTRASOUND FOR DETECTING NEONATAL MIDDLE CEREBRAL ARTERY STROKE
    Olive, Gemma
    Agut, Thais
    Mario Echeverria-Palacio, Carlos
    Arca, Gemma
    Garcia-Alix, Alfredo
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (03): : 885 - 890
  • [34] A cross sectional study evaluating screening using maternal anthropometric measurements for outcomes of childbirth in Ugandan mothers at term
    Munabi I.G.
    Luboga S.A.
    Mirembe F.
    BMC Research Notes, 8 (1)
  • [35] Changes in cerebral oxygenation and hemodynamics during cranial ultrasound in preterm infants
    van Alfen-van der Velden, Adriana A. E. M.
    Claessen, Vivian P. J.
    Hopman, Jeroen C. W.
    Klaessens, John H. G. M.
    Sengers, Rob C. A.
    Liem, Kian D.
    BRAIN & DEVELOPMENT, 2009, 31 (06): : 427 - 434
  • [36] CRANIAL ULTRASOUND AFTER FORCEFUL MIDPELVIS VACUUM EXTRACTION AT TERM
    JEANNIN, P
    AFSCHRIFT, M
    VOET, D
    VANDEKERCKHOVE, F
    THIERY, M
    DEFOORT, P
    DEROM, R
    JOURNAL OF PERINATAL MEDICINE, 1984, 12 (06) : 319 - 323
  • [37] Ultrasound measurements of the newborn hip - comparison of two methods in 657 newborns
    Czubak, J
    Kotwicki, T
    ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (05): : 550 - 551
  • [38] Ultrasound measurements of the newborn hip - Comparison of two methods in 657 newborns
    Czubak, J
    Kotwicki, T
    Piontek, T
    Skrzypek, H
    ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (01): : 21 - 24
  • [39] Cranial ultrasound and MRI at term age in extremely preterm infants
    Horsch, S.
    Skiold, B.
    Hallberg, B.
    Nordell, B.
    Nordell, A.
    Mosskin, M.
    Lagercrantz, H.
    Aden, U.
    Blennow, M.
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2010, 95 (05): : F310 - F314
  • [40] The utility of the fronto-temporal horn ratio on cranial ultrasound in premature newborns: a ventriculomegaly marker
    Obeid, Rawad
    Jacobs, Marni
    Chang, Taeun
    Massaro, An N.
    Bluth, Eresha
    Murnick, Jonathan G.
    Bulas, Dorothy
    Bandarkar, Anjum
    Oluigbo, Chima
    Penn, Anna A.
    PEDIATRIC RESEARCH, 2021, 89 (07) : 1715 - 1723