Determination of five antiarrhythmic drugs in human plasma by dispersive liquid-liquid microextraction and high-performance liquid chromatography

被引:61
|
作者
Jouyban, Abolghasem [1 ,2 ]
Sorouraddin, Mohammad Hossein [3 ]
Farajzadeh, Mir Ali [3 ]
Somi, Mohammad Hossein [4 ]
Fazeli-Bakhtiyari, Rana [3 ,4 ]
机构
[1] Tabriz Univ Med Sci, Drug Appl Res Ctr, Tabriz, Iran
[2] Tabriz Univ Med Sci, Fac Pharm, Tabriz, Iran
[3] Univ Tabriz, Fac Chem, Dept Analyt Chem, Tabriz, Iran
[4] Tabriz Univ Med Sci, Liver & Gastrointestinal Dis Res Ctr, Tabriz, Iran
关键词
Dispersive liquid-liquid microextraction; High-performance liquid chromatography-ultraviolet; Method validation; Antiarrhythmic drugs; Plasma; SOLID-PHASE EXTRACTION; TANDEM MASS-SPECTROMETRY; CAPILLARY-ZONE-ELECTROPHORESIS; FLOATING ORGANIC DROPLET; BETA-BLOCKER DRUGS; HUMAN URINE; CARDIOVASCULAR DRUGS; GAS-CHROMATOGRAPHY; SCREENING METHOD; DOPING AGENTS;
D O I
10.1016/j.talanta.2014.12.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast and sensitive high-performance liquid chromatography (HPLC) method with ultraviolet (UV) detection was developed and validated for the simultaneous quantitation of five antiarrhythmic drugs (metoprolol, propranolol, carvedilol, diltiazem, and verapamil) in human plasma samples. It involves dispersive liquid-liquid microextraction (DLLME) of the desired drugs from 660 mu L plasma and separation using isocratic elution with UV detection at 200 nm. The complete separation of all analytes was achieved within 7 min. Acetonitrile (as disperser solvent) resulting from the protein precipitation procedure was mixed with 100 mu L dichloromethane (as an extraction solvent) and rapidly injected into 5 mL aqueous solution (pH 11.5) containing 1% (w/v), NaCl. After centrifugation, the sedimented phase containing enriched analytes was collected and evaporated to dryness. The residue was re-dissolved in 50 mu L deionized water (acidified to pH 3) and injected into the HPLC system for analysis. Under the optimal conditions, the enrichment factors and extraction recoveries ranged between 4.4-10.8 and 33-82%, respectively. The suggested method was linear (r(2) >= 0.997) over a dynamic range of 0.02-0.80 mu g mL(-1) in plasma. The intra- and inter-days relative standard deviation (RSD%) and relative error (RE%) values of the method were below 20%, which shows good precision and accuracy. Finally, this method was applied to the analysis of real plasma samples obtained from the patients treated with these drugs. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:681 / 689
页数:9
相关论文
共 50 条
  • [31] Determination of trace bisphenol A in water by high performance liquid chromatography with dispersive liquid-liquid microextraction
    Energy and Environment Research Centre, North China Electric Power University, Beijing 102206, China
    不详
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao, 2008, 11 (2142-2148): : 2142 - 2148
  • [32] Determination of Trace Bisphenol A in Water by High Performance Liquid Chromatography with Dispersive Liquid-liquid Microextraction
    Li Yu
    Liu Jian-Lin
    Wang Xiao-Li
    Jian Ying-Hong
    Dong De-Ming
    Li Na
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2008, 29 (11): : 2142 - 2148
  • [33] Determination of finasteride in human plasma by liquid-liquid extraction and high-performance liquid chromatography
    Ptácek, P
    Macek, J
    Klíma, J
    JOURNAL OF CHROMATOGRAPHY B, 2000, 738 (02): : 305 - 310
  • [34] Ionic-liquid-based dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography for the forensic determination of methamphetamine in human urine
    Wang, Ruifeng
    Qi, Xiujuan
    Zhao, Lei
    Liu, Shimin
    Gao, Shuang
    Ma, Xiangyuan
    Deng, Youquan
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (13) : 2444 - 2450
  • [35] DETERMINATION OF TETRACYCLINES IN WATER BY ETHYL ACETATE-IONIC LIQUID DISPERSIVE LIQUID-LIQUID MICROEXTRACTION AND HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
    Du, Dongli
    Wu, Yuanyuan
    Kang, Duan
    Wang, Huili
    Huang, Changjiang
    Li, Yanyan
    ANALYTICAL LETTERS, 2014, 47 (10) : 1783 - 1795
  • [36] In-syringe ionic liquid dispersive liquid-liquid microextraction for the determination of sulfonamides in blood using high-performance liquid chromatography
    Yu, Wei
    Liu, Zhongling
    Cui, Shusen
    Zhang, Shaohua
    Yang, Xiao
    Lei, Lei
    Zhang, Hanqi
    Yu, Aimin
    ANALYTICAL METHODS, 2014, 6 (08) : 2545 - 2552
  • [37] Determination of fluoroquinolone drugs in meat by ionic-liquid-based dispersive liquid-liquid microextraction-high performance liquid chromatography
    Wang, Geng Nan
    Feng, Cheng
    Zhang, Hui Cai
    Zhang, Ying Qun
    Zhang, Lei
    Wang, Jian Ping
    ANALYTICAL METHODS, 2015, 7 (03) : 1046 - 1052
  • [38] Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography as an efficient and sensitive technique for determination of nandrolone and testosterone in human urine
    Rezaee, Mohammad
    ACTA CHROMATOGRAPHICA, 2023, 35 (01) : 28 - 34
  • [39] Application of dispersive liquid-liquid microextraction combined with high-performance liquid chromatography to the determination of carbamate pesticides in water samples
    Wu, Qiuhua
    Zhou, Xin
    Li, Yuemin
    Zang, Xiaohuan
    Wang, Chun
    Wang, Zhi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (6-7) : 1755 - 1761
  • [40] Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography for the determination of three carbamate pesticides in water samples
    He, Lijun
    Wang, Chunjian
    Sun, Yinjuan
    Luo, Xianli
    Zhang, Jing
    Lu, Kui
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2009, 89 (06) : 439 - 448