AC Corrosion Evaluation of Cathodically Protected Pipeline Steel

被引:9
|
作者
Moran, Andrew [1 ]
Lillard, Robert Scott [1 ]
机构
[1] Univ Akron, Dept Chem Biomol & Corros Engn, 264 Wolf Ledges Pkwy, Akron, OH 44325 USA
关键词
AC corrosion; alternating current; capacitance; cathodic protection; pipeline; soil; soil type; steel; CAPACITANCE;
D O I
10.5006/3074
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The effect of alternating current (AC) on the corrosion rates of cathodically protected buried steel pipeline was investigated through mass loss testing. Results indicate that cathodic protection (CP) at potentials at or below the CP criteria of -780 mV(SCE) is adequate to prevent increased corrosion due to AC at AC densities up to 350 A/m(2). Further, the interfacial capacitance of the steel was theorized to be a controlling factor in the ratio of the capacitive to faradaic current portions of the AC and thus the corrosion rates due to AC. The value of capacitance was measured in various soil types to determine the effect of the bulk environment on this parameter. It was found that interfacial capacitance is much lower in artificial soils than in a soil-simulating solution but that the composition of the soils does not greatly affect the capacitance.
引用
收藏
页码:144 / 146
页数:3
相关论文
共 50 条
  • [41] AC corrosion of steel pipeline under cathodic protection: A state-of-the-art review
    Farahani, Emadoddin Majdabadi
    Su, Yuhan
    Chen, Xiao
    Wang, Hao
    Laughorn, Tyler R.
    Onesto, Frank
    Zhou, Qixin
    Huang, Qindan
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2024, 75 (03): : 290 - 314
  • [42] A Theory and Design of an Insulating Insert in a Cathodically Protected Underground Water Pipeline. II. The Corrosion Rate of Anodic Zones and Effectiveness of the Insert
    L. I. Freiman
    Protection of Metals, 2002, 38 : 277 - 283
  • [43] A theory and design of an insulating insert in a cathodically protected underground water pipeline. II. The corrosion rate of anodic zones and effectiveness of the insert
    Freiman, LI
    PROTECTION OF METALS, 2002, 38 (03): : 277 - 283
  • [44] A mathematical model for modeling the formation of calcareous deposits on cathodically protected steel in seawater
    Sun, Wen
    Liu, Guichang
    Wang, Lida
    Li, Yu
    ELECTROCHIMICA ACTA, 2012, 78 : 597 - 608
  • [45] Status of Cathodically Protected Steel Sheet Wharf Piles After 30 Years
    Zhu Xichang
    Ge Yan
    Li Yan
    Shen Jingwen
    Fang Weidong
    MATERIALS PERFORMANCE, 2009, 48 (12) : 29 - 33
  • [46] A theory and design of an insulating insert in a cathodically protected underground water pipeline. II. The corrosion rate of anodic zones and effectiveness of the insert
    Acad. of Municipal Services, Volokolamskoe sh. 116, Moscow, 123371, Russia
    Zashch Met, 3 (315-321):
  • [47] AC grounding of cathodically protected structures using solid-state decoupling devices
    Tachick, H
    MATERIALS PERFORMANCE, 2001, 40 (02) : 20 - 25
  • [48] Hydrogen absorption by cathodically protected underground steel piping in thiosulfate containing media
    Hu, RP
    Manolatos, P
    Jerome, M
    Meyer, M
    Galland, J
    CORROSION SCIENCE, 1998, 40 (4-5) : 619 - 629
  • [49] Effect of Iron Ion on the Evaluation of Buried-Steel Pipeline Corrosion
    Feng, Jianguo
    Wu, Cong
    Zhang, Jingsi
    Qin, Chaokui
    Chen, Zhiguang
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2022, 34 (04)
  • [50] Time evolution of Electrochemical Impedance spectra of cathodically protected steel in artificial seawater
    Narozny, M.
    Zakowski, K.
    Darowicki, K.
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 154 : 88 - 94