Current status of external quality assessment of syphilis test in Korea

被引:3
|
作者
Song, Eun Young [1 ]
Yang, Joo-Seok [2 ]
Chae, Seok-Lae [3 ]
Kim, Serim [1 ]
Choi, Young Sook [1 ]
Cha, Young-Joo [4 ]
机构
[1] Konkuk Univ, Coll Med, Dept Lab Med, Seoul, South Korea
[2] Chung Ang Univ Hosp, Seoul, South Korea
[3] Dongguk Univ, Coll Med, Goyang, South Korea
[4] Chung Ang Univ, Coll Med, Seoul 156756, South Korea
来源
KOREAN JOURNAL OF LABORATORY MEDICINE | 2008年 / 28卷 / 03期
关键词
external quality assessment; syphilis; non-treponemal test; treponemal test;
D O I
10.3343/kjlm.2008.28.3.207
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background : Current status of external quality assessment (EQA) of laboratory tests for syphilis in Korea was analyzed to find out the problems that should be improved in the future. Methods : Based on the data from the external quality assessment program performed twice a year by the Immunoserology Subcommittee of the Korean Association of Quality Assurance for Clinical Laboratory from the year 2004 to 2006, discordance rates were analyzed according to the test method and commercial kit used. Results: Among the laboratories participating in the EQA program for syphilis test, about 90% of them used non-treponemal tests and about 55% treponemal tests. The non-treponemal tests included RPR (rapid plasma reagin) and VDRL tests used in 88% (363/412) and 11% (45/412), respectively, of the laboratories. The discordance rates were 2.2% for RPR test and 3.6% for VDRL. For the treponemal tests, Treponema pallidum hemagglutination assay (TPHA) was used in 60-76% and Immunochromatography assay (ICA) in about 30% of the laboratories in 2006. A high discordance rate of over 10% was reported in both TPHA and in ICA methods, possibly due to a low titer (1:1 in VDRL) of EQA samples in 2005. Analysis of the accumulated data from year 2004 to 2006 showed that the discordance rates of TPHA, ICA, and FTA-ABS were 4.6%, 3.7%, and 2.7%, respectively. Conclusions : For syphilis tests, RPR test, TPHA, and ICA are mainly used in Korea. A high discordance rate is still reported in TPHA and ICA, especially when testing samples with a low titer. Further analysis of data and education of laboratory personnel are needed for the improvement of the EQA program.
引用
收藏
页码:207 / 213
页数:7
相关论文
共 50 条
  • [31] Current status of quality of life assessment in schizophrenic patients
    Bobes, Julio
    EUROPEAN ARCHIVES OF PSYCHIATRY AND CLINICAL NEUROSCIENCE, 2001, 251 (Suppl 2) : 38 - 42
  • [32] Current status of quality of life assessment in schizophrenic patients
    Julio Bobes
    European Archives of Psychiatry and Clinical Neuroscience, 2001, 251 : 38 - 42
  • [33] Assessment of quality test methods for solid recovered fuel in South Korea
    Yang, Won-Seok
    Lee, Young-Jin
    Kang, Jun-Gu
    Shin, Sun-Kyoung
    Jeon, Tae-Wan
    WASTE MANAGEMENT, 2020, 103 : 240 - 250
  • [34] Quantitative Evaluation of the Real-World Harmonization Status of Laboratory Test Items Using External Quality Assessment Data
    Kim, Sollip
    Jeong, Tae-Dong
    Lee, Kyunghoon
    Chung, Jae-Woo
    Cho, Eun-Jung
    Lee, Seunghoo
    Chun, Sail
    Song, Junghan
    Min, Won-Ki
    ANNALS OF LABORATORY MEDICINE, 2024, 44 (06) : 529 - 536
  • [35] Current status of syphilis in pregnant women in Japan
    Suzuki, Shunji
    Sekizawa, Akihiko
    Tanaka, Masanobu
    Okai, Takashi
    Kinoshita, Katsuyuki
    Kitamura, Tadaichi
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2017, 30 (23): : 2881 - 2883
  • [36] External quality assessment in molecular immunohematology: the INSTAND proficiency test program
    Flegel, Willy A.
    Chiosea, Ion
    Sachs, Ulrich J.
    Bein, Gregor
    TRANSFUSION, 2013, 53 (11) : 2850 - 2858
  • [37] Proficiency Testing/External Quality Assessment: Current Challenges and Future Directions
    Miller, W. Greg
    Jones, Graham R. D.
    Horowitz, Gary L.
    Weykamp, Cas
    CLINICAL CHEMISTRY, 2011, 57 (12) : 1670 - 1680
  • [38] Current status and development trend of power quality comprehensive assessment
    Liu Y.
    Feng D.
    Lin C.
    Zhang Y.
    2020, Power System Protection and Control Press (48): : 167 - 176
  • [39] THE CURRENT STATUS OF QUALITY-OF-LIFE ASSESSMENT IN SURGICAL INVESTIGATIONS
    SPRANGERS, MAG
    AARONSON, NK
    THEORETICAL SURGERY, 1991, 6 (03): : 158 - 165
  • [40] Current Status of Overseas Transplantation in Korea
    Ahn, Hyung Joon
    Kwon, Oh Jung
    Ahn, Curie
    TRANSPLANTATION, 2018, 102 : S613 - S613