Pavlovian control of intraspinal microstimulation to produce over-ground walking

被引:12
|
作者
Dalrymple, Ashley N. [1 ,4 ]
Roszko, David A. [1 ,4 ]
Sutton, Richard S. [2 ,4 ]
Mushahwar, Vivian K. [1 ,3 ,4 ]
机构
[1] Univ Alberta, Neurosci & Mental Hlth Inst, Edmonton, AB, Canada
[2] Univ Alberta, Fac Sci, Dept Comp Sci, Edmonton, AB, Canada
[3] Univ Alberta, Fac Med & Dent, Dept Med, Div Phys Med & Rehabil, Edmonton, AB, Canada
[4] Univ Alberta, Sensory Motor Adapt Rehabil Technol SMART Network, Edmonton, AB, Canada
基金
加拿大健康研究院;
关键词
machine learning; neural prosthesis; spinal cord injury; walking; functional electrical stimulation; Pavlovian control; reinforcement learning; FUNCTIONAL ELECTRICAL-STIMULATION; SPINAL-CORD STIMULATION; FINITE-STATE CONTROL; SELECTIVE ACTIVATION; MUSCLE GROUPS; FES SYSTEM; CAT; RECOVERY; HINDLIMB; INJURY;
D O I
10.1088/1741-2552/ab8e8e
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Neuromodulation technologies are increasingly used for improving function after neural injury. To achieve a symbiotic relationship between device and user, the device must augment remaining function, and independently adapt to day-to-day changes in function. The goal of this study was to develop predictive control strategies to produce over-ground walking in a model of hemisection spinal cord injury (SCI) using intraspinal microstimulation (ISMS). Approach. Eight cats were anaesthetized and placed in a sling over a walkway. The residual function of a hemisection SCI was mimicked by manually moving one hind-limb through the walking cycle. ISMS targeted motor networks in the lumbosacral enlargement to activate muscles in the other, presumably 'paralyzed' limb, using low levels of current (mu A). Four people took turns to move the 'intact' limb, generating four different walking styles. Two control strategies, which used ground reaction force and angular velocity information about the manually moved 'intact' limb to control the timing of the transitions of the 'paralyzed' limb through the step cycle, were compared. The first strategy used thresholds on the raw sensor values to initiate transitions. The second strategy used reinforcement learning and Pavlovian control to learn predictions about the sensor values. Thresholds on the predictions were then used to initiate transitions. Main results. Both control strategies were able to produce alternating, over-ground walking. Transitions based on raw sensor values required manual tuning of thresholds for each person to produce walking, whereas Pavlovian control did not. Learning occurred quickly during walking: predictions of the sensor signals were learned rapidly, initiating correct transitions after <= 4 steps. Pavlovian control was resilient to different walking styles and different cats, and recovered from induced mistakes during walking. Significance. This work demonstrates, for the first time, that Pavlovian control can augment remaining function and facilitate personalized walking with minimal tuning requirements.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Control strategy for intraspinal microstimulation based on central pattern generator
    Lou, Xiongjie
    Wu, Yan
    Lu, Song
    Shen, Xiaoyan
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2023, 26 (03) : 305 - 314
  • [32] OVER-GROUND POWER TRANSMISSION LINE SYSTEMS
    VAGO, I
    PERIODICA POLYTECHNICA-ELECTRICAL ENGINEERING, 1965, 9 (01): : 67 - &
  • [33] Weight-supported treadmill vs over-ground training for walking after acute incomplete SCI
    Wernig, Anton
    NEUROLOGY, 2006, 67 (10) : 1900 - 1900
  • [34] Sensitivity of Local Dynamic Stability of Over-Ground Walking to Balance Impairment Due to Galvanic Vestibular Stimulation
    Lizeth H. Sloot
    Kimberley S. van Schooten
    Sjoerd M. Bruijn
    Herman Kingma
    Mirjam Pijnappels
    Jaap H. van Dieën
    Annals of Biomedical Engineering, 2011, 39 : 1563 - 1569
  • [35] Sensitivity of Local Dynamic Stability of Over-Ground Walking to Balance Impairment Due to Galvanic Vestibular Stimulation
    Sloot, Lizeth H.
    van Schooten, Kimberley S.
    Bruijn, Sjoerd M.
    Kingma, Herman
    Pijnappels, Mirjam
    van Dieen, Jaap H.
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (05) : 1563 - 1569
  • [36] Over-ground Vs. Treadmill Walking In Older Adults: Comparison Of Accelerometry Counts And Metabolic Demands
    Glynn, Nancy W.
    Santanasto, Adam J.
    Newman, Mark A.
    Taylor, Christopher A.
    Newman, Anne B.
    Goodpaster, Bret H.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 818 - 818
  • [37] Block-based robust control of stepping using intraspinal microstimulation
    Rouhani, Ehsan
    Erfanian, Abbas
    JOURNAL OF NEURAL ENGINEERING, 2018, 15 (04)
  • [38] Clinical utility of the over-ground bodyweight-supporting walking system Andago in children and youths with gait impairments
    Hubertus J. A. van Hedel
    Irene Rosselli
    Sandra Baumgartner-Ricklin
    Journal of NeuroEngineering and Rehabilitation, 18
  • [39] Coordination of muscles to control the footpath during over-ground walking in neurologically intact individuals and stroke survivors (vol 234, pg 1903, 2016)
    Srivastava, Shraddha
    Kao, Pei-Chun
    Reisman, Darcy S.
    Higginson, Jill S.
    Scholz, John P.
    EXPERIMENTAL BRAIN RESEARCH, 2018, 236 (06) : 1835 - 1835
  • [40] Comparison of body's center of mass motion relative to center of pressure between treadmill and over-ground walking
    Lu, Hsuan-Lun
    Lu, Tung-Wu
    Lin, Hsiu-Chen
    Chan, Wing P.
    GAIT & POSTURE, 2017, 53 : 248 - 253