Comparison of quantification strategies for one-point standard addition calibration: The heteroscedastic case

被引:3
|
作者
Brown, Richard J. C. [1 ]
Gillam, Thomas P. S. [2 ]
机构
[1] Natl Phys Lab, Analyt Sci Div, Teddington TW11 0LW, Middx, England
[2] Univ Cambridge, Cavendish Lab, Dept Phys, Cambridge CB3 0HE, England
关键词
Standard addition; Calibration; Precision; Extrapolation; Comparison; SYSTEMATIC-ERROR;
D O I
10.1016/j.measurement.2012.03.020
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Two quantification strategies for one-point standard addition calibration have been compared mathematically. One strategy involved the extrapolation of measurement points to their intercept with the x-axis to determine the analyte content in the unknown sample, and the other strategy is based upon direct calculation of the analyte content in the unknown sample using the instrumental responses obtained during measurement. The cases of both conventional standard addition calibration (C-SAC) and sequential standard addition calibration (S-SAC) have been considered. The heteroscedastic situation has been considered, where the relative precision of instrumental responses is constant. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1670 / 1673
页数:4
相关论文
共 50 条
  • [31] Driver's eye-based gaze tracking system by one-point calibration
    Yoon, Hyo Sik
    Hong, Hyung Gil
    Lee, Dong Eun
    Park, Kang Ryoung
    MULTIMEDIA TOOLS AND APPLICATIONS, 2019, 78 (06) : 7155 - 7179
  • [32] GaVe: A Webcam-Based Gaze Vending Interface Using One-Point Calibration
    Zeng, Zhe
    Liu, Sai
    Cheng, Hao
    Liu, Hailong
    Li, Yang
    Feng, Yu
    Siebert, Felix Wilhelm
    JOURNAL OF EYE MOVEMENT RESEARCH, 2023, 16 (01):
  • [33] A CMOS Temperature Sensor with a Maximum Accuracy of 1.6 °C after One-Point Calibration
    Chen, Chun-Chi
    Liu, Keng-Chih
    Lin, Shih-Hao
    INDUSTRIAL INSTRUMENTATION AND CONTROL SYSTEMS II, PTS 1-3, 2013, 336-338 : 216 - 220
  • [34] Assessing visual attention in virtual reality: Automatic one-point calibration for eye-tracking
    Lutz, Otto Hans-Martin
    Krueger, Joerg
    2017 INTERNATIONAL CONFERENCE ON VIRTUAL REHABILITATION (ICVR), 2017,
  • [36] ONE-POINT CALIBRATION OF ALLEN-BRADLEY RESISTOR THERMOMETERS, 2-20 K
    LAWLESS, WN
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1977, 48 (03): : 361 - 362
  • [37] One-point and multi-line calibration method in laser-induced breakdown spectroscopy
    Hao, Z. Q.
    Liu, L.
    Zhou, R.
    Ma, Y. W.
    Li, X. Y.
    Guo, L. B.
    Lu, Y. F.
    Zeng, X. Y.
    OPTICS EXPRESS, 2018, 26 (18): : 22926 - 22933
  • [38] A Physical Model-Based Approach to One-Point Calibration of Pulse Transit Time to Blood Pressure
    Mousavi, Azin
    Inan, Omer T.
    Mukkamala, Ramakrishna
    Hahn, Jin-Oh
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (02) : 477 - 483
  • [39] One-Point Calibration of Low-Cost Sensors for Particulate Air Matter (PM) Concentration Measurement
    Russi, Luigi
    Guidorzi, Paolo
    Semprini, Giovanni
    Trentini, Arianna
    Pulvirenti, Beatrice
    SENSORS, 2025, 25 (03)
  • [40] Self-absorption correction method for one-point calibration laser-induced breakdown spectroscopy
    Hu, Zhenlin
    Nie, Junfei
    Ouyang, Zhiyong
    Zhang, Deng
    Liu, Yuanchao
    Chu, Yanwu
    Guo, Lianbo
    OPTICS LETTERS, 2023, 48 (01) : 1 - 4