Comparison of quantification strategies for one-point standard addition calibration: The heteroscedastic case

被引:3
|
作者
Brown, Richard J. C. [1 ]
Gillam, Thomas P. S. [2 ]
机构
[1] Natl Phys Lab, Analyt Sci Div, Teddington TW11 0LW, Middx, England
[2] Univ Cambridge, Cavendish Lab, Dept Phys, Cambridge CB3 0HE, England
关键词
Standard addition; Calibration; Precision; Extrapolation; Comparison; SYSTEMATIC-ERROR;
D O I
10.1016/j.measurement.2012.03.020
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Two quantification strategies for one-point standard addition calibration have been compared mathematically. One strategy involved the extrapolation of measurement points to their intercept with the x-axis to determine the analyte content in the unknown sample, and the other strategy is based upon direct calculation of the analyte content in the unknown sample using the instrumental responses obtained during measurement. The cases of both conventional standard addition calibration (C-SAC) and sequential standard addition calibration (S-SAC) have been considered. The heteroscedastic situation has been considered, where the relative precision of instrumental responses is constant. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1670 / 1673
页数:4
相关论文
共 50 条
  • [1] Comparison of quantification strategies for one-point standard addition calibration: The homoscedastic case
    Brown, Richard J. C.
    Gillam, Thomas P. S.
    ANALYTICA CHIMICA ACTA, 2012, 716 : 108 - 111
  • [2] One-Point Microwave Radiometer Calibration
    Corbella, Ignasi
    Tones, Francesc
    Closa, Josep
    Duffo, Nuria
    Duran, Israel
    Gonzalez-Gambau, Veronica
    Martin-Neira, Manuel
    IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2020, 17 (03) : 461 - 463
  • [3] Fast neonicotinoid quantification in honey using the one-point internal calibration approach
    Visconti, Gioele
    de Figueiredo, Miguel
    Monnier, Joanie
    Shea, Julia
    Rudaz, Serge
    Glauser, Gaetan
    FOOD CHEMISTRY-X, 2024, 23
  • [4] Application of one-point calibration LIBS for quantification of analytes in samples with distinct matrix characteristics: a case study with Hg
    Leva Borduchi, Luis Carlos
    Menegatti, Carlos Renato
    Milori, Debora Marcondes Bastos Pereira
    Izario Filho, Helcio Jose
    Villas-Boas, Paulino Ribeiro
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (05) : 1155 - 1163
  • [5] Quantification of Camellia oleifera extract in complete feed with UHPLC-MS/MS using a double "one-point" standard addition
    Le Bot, M.
    Cisse, S.
    Guilet, D.
    PLANTA MEDICA, 2022, 88 (15) : 1448 - 1448
  • [6] A novel gaze estimation method with one-point calibration
    Xiong, C.-S. (chunshui.xiong@ia.ac.cn), 1600, Science Press (40):
  • [7] THE ONE-POINT DEBATE - AN ADDITION TO THE BEGINNING SPEECH COURSE
    VERDERBER, RF
    SPEECH TEACHER, 1963, 12 (02): : 125 - 126
  • [8] Quantification of Citrus limon (L.) Burmin in complete feed with UHPLC-MS/MS using a double "one-point" standard addition
    Maxime, Le Bot
    Sekhou, Cisse
    David, Guilet
    PLANTA MEDICA, 2021, 87 (15) : 1271 - 1271
  • [9] Systematic comparison of bias and precision data obtained with multiple-point and one-point calibration in six validated multianalyte assays for quantification of drugs in human plasma
    Peters, Frank T.
    Maurer, Hans H.
    ANALYTICAL CHEMISTRY, 2007, 79 (13) : 4967 - 4976
  • [10] A One-Point Calibration Design for Hybrid Eye Typing Interface
    Zeng, Zhe
    Neuer, Elisabeth Sumithra
    Roetting, Matthias
    Siebert, Felix Wilhelm
    INTERNATIONAL JOURNAL OF HUMAN-COMPUTER INTERACTION, 2023, 39 (18) : 3620 - 3633