High-energy 3D calorimeter for use in gamma-ray astronomy based on position-sensitive virtual Frisch-grid CdZnTe detectors

被引:1
|
作者
Moiseev, A. [1 ,2 ]
Bolotnikov, A. [3 ]
DeGeronimo, G. [3 ]
Hays, E. [4 ]
James, R. [5 ]
Thompson, D. [4 ]
Vernon, E. [3 ]
机构
[1] NASA, CRESST, GSFC, Greenbelt, MD 20771 USA
[2] Univ Maryland, Greenbelt, MD 20771 USA
[3] Brookhaven Natl Lab, Upton, NY 11973 USA
[4] NASA, GSFC, Greenbelt, MD 20771 USA
[5] Savannah River Natl Lab, Savannah River, SC USA
来源
JOURNAL OF INSTRUMENTATION | 2017年 / 12卷
关键词
Calorimeters; Gamma detectors (scintillators; CZT; HPG; HgI etc); Space instrumentation; Gamma telescopes;
D O I
10.1088/1748-0221/12/12/C12037
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We will present a concept for a calorimeter based on a novel approach of 3D position-sensitive virtual Frisch-grid CdZnTe (hereafter CZT) detectors. This calorimeter aims to measure photons with energies from similar to 100 keV to 20-50MeV. The expected energy resolution at 662 keV is better than 1% FWHM, and the photon interaction position-measurement accuracy is better than 1 mm in all 3 dimensions. Each CZT bar is a rectangular prism with typical cross-section from 5 x 5 to 7 x 7mm2 and length of 2-4 cm. The bars are arranged in modules of 4 x 4 bars, and the modules themselves can be assembled into a larger array. The 3D virtual voxel approach solves a long-standing problem with CZT detectors associated with material imperfections that limit the performance and usefulness of relatively thick detectors (i.e., > 1 cm). Also, it allows us to use the standard (unselected) grade crystals, while achieving the energy resolution of the premium detectors and thus substantially reducing the cost of the instrument. Such a calorimeter can be successfully used in space telescopes that use Compton scattering of gamma-rays, such as AMEGO, serving as part of its calorimeter and providing the position and energy measurement for Compton-scattered photons (like a focal plane detector in a Compton camera). Also, it could provide suitable energy resolution to allow for spectroscopic measurements of gamma-ray lines from nuclear decays.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] High altitude balloon flights of position sensitive CdZnTe detectors for high energy X-ray astronomy
    Slavis, KR
    Dowkontt, P
    Duttweiler, F
    Epstein, J
    Hink, PL
    Huszar, GL
    Leblanc, PC
    Matteson, JL
    Skelton, RT
    Stephan, E
    FIFTH COMPTON SYMPOSIUM, 2000, 510 : 764 - 768
  • [32] Detection of gamma ray polarization using a 3-D position-sensitive CdZnTe detector
    Xu, D
    He, Z
    Zhang, F
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 1160 - 1164
  • [33] Large-area atmospheric Cherenkov detectors for high-energy gamma-ray astronomy
    Ong, RA
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA C-GEOPHYSICS AND SPACE PHYSICS, 1996, 19 (06): : 971 - 979
  • [34] Development of a 3D Imaging Calorimeter in Lanthanum Bromide for Gamma-Ray Space Astronomy
    Gostojic, Aleksandar
    Tatischeff, Vincent
    Kiener, Jurgen
    Hamadache, Clarisse
    Karkour, Nabil
    Linget, Denis
    Sedes, Gregory
    Blin, Sylvie
    Barrillon, Pierre
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [35] Effects of charge sharing in 3-D position sensitive CdZnTe gamma-ray spectrometers
    He, Z
    Li, W
    Knoll, GF
    Wehe, DK
    Du, YF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 439 (2-3): : 619 - 624
  • [36] Hand-held gamma-ray spectrometer based on high-efficiency Frisch-ring CdZnTe detectors
    Cui, Y.
    Bolotnikov, A.
    Camarda, G.
    Hossain, A.
    James, R. B.
    De Geronimo, G.
    Fried, J.
    O'Connor, P.
    Kargar, A.
    Harrison, M. J.
    McGregor, D. S.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 945 - 948
  • [37] Hand-Held Gamma-Ray Spectrometer Based on High-Efficiency Frisch-Ring CdZnTe Detectors
    Cui, Yonggang
    Bolotnikov, Aleksey
    Camarda, Giuseppe
    Hossain, Anwar
    James, Ralph B.
    De Geronimo, Gianluigi
    Fried, Jack
    O'Connor, Paul
    Kargar, Alireza
    Harrison, Mark J.
    McGregor, Douglas S.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (05) : 2765 - 2769
  • [38] A 3-DIMENSIONAL HIGH-ENERGY PHOTON DETECTOR FOR GAMMA-RAY ASTRONOMY
    HALL, CJ
    DEAN, AJ
    BYARD, K
    GOLDWURM, A
    BUSSINI, A
    VILLA, G
    CAROLI, E
    DICOCCO, G
    LABANTI, C
    MALAGUTI, G
    NATALUCCI, L
    SPIZZICHINO, A
    AGRINIER, B
    SWINYARD, BM
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY AND ATOMIC PHYSICS, 1989, 1159 : 81 - 90
  • [39] Detection of gamma ray polarization using a 3D position sensitive CdZnTe detector
    Xu, D
    He, Z
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 376 - 380
  • [40] Ground-based detectors in very-high-energy gamma-ray astronomy
    de Naurois, Mathieu
    Mazin, Daniel
    COMPTES RENDUS PHYSIQUE, 2015, 16 (6-7) : 610 - 627