Static sensitivity of whole-room indirect calorimeters

被引:0
|
作者
Bandini, Gabriele [1 ]
Landi, Alberto [2 ]
Santini, Ferruccio [3 ]
Basolo, Alessio [3 ]
Marracci, Mirko [1 ]
Piaggi, Paolo [2 ]
机构
[1] Univ Pisa, Dept Energy Syst Terr & Construct Engn, Pisa, Italy
[2] Univ Pisa, Dept Informat Engn, Pisa, Italy
[3] Univ Hosp Pisa, Dept Clin & Expt Med, Pisa, Italy
关键词
Sensitivity analysis; static sensitivity; energy metabolism; indirect calorimetry; metabolic chamber; ENERGY-EXPENDITURE; DETERMINANTS;
D O I
10.1109/MEMEA54994.2022.9856550
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Whole-room indirect calorimeters (WRIC) are accurate tools to precisely measure energy metabolism in humans via calculation of oxygen consumption and carbon dioxide production. Yet, overall accuracy of metabolic measurements relies on the validity of the theoretical model for gas exchange inside the WRIC volume in addition to experimental and environmental conditions that contribute to the uncertainty of WRIC outcome variables. The aim of this study was to quantitatively study the static sensitivity of a WRIC operated in a push configuration and located at the laboratories of the University Hospital of Pisa with the goal to identify the experimental conditions required to reach the best degree of accuracy for outcome metabolic measurements. Herein we demonstrate that achieving a fractional concentration of carbon dioxide inside the WRIC >0.2% at the steady state conditions allows to obtain a relative uncertainty <5% for the outcome metabolic measurements.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Practical utility and reliability of whole-room calorimetry in young children
    Janssen, Xanne
    Cliff, Dylan
    Okely, Anthony D.
    Jones, Rachel A.
    Batterham, Marijka
    Ekelund, Ulf
    Brage, Soren
    Reilly, John J.
    BRITISH JOURNAL OF NUTRITION, 2013, 109 (10) : 1917 - 1922
  • [22] Energy Expenditure Measured Overnight In A Whole-room Indirect Calorimeter In Four Collegiate American-style Football Linemen
    Allerton, Timothy D.
    Ravussin, Eric
    Rood, Jennifer
    Irving, Brian
    Lemoine, Nathan
    Mullenix, Shelly
    Marucci, Jack
    Johannsen, Neil
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 343 - 343
  • [23] Validity and reproducibility of a whole-room indirect calorimeter for the estimation of VO2, VCO2, and resting metabolic rate
    Henriksen, Hege Berg
    Henriksen, Christine
    de Sousa, Ana Rita Sequeira
    Alavi, Dena Treider
    Augestad, Elin Maria Sandstad
    Rising, Russell
    Doerner, Rebecca
    Haegele, Franziska Anna
    Bosy-Westphal, Anja
    Blomhoff, Rune
    Ulven, Stine Marie
    Olsen, Thomas
    PHYSIOLOGICAL REPORTS, 2023, 11 (07):
  • [24] Appropriateness of the definition of 'sedentary' in young children: Whole-room calorimetry study
    Reilly, John J.
    Janssen, Xanne
    Cliff, Dylan P.
    Okely, Anthony D.
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2015, 18 (05) : 565 - 568
  • [25] Experimental sleep curtailment causes wake-dependent increases in 24-h energy expenditure as measured by whole-room indirect calorimetry
    Shechter, Ari
    Rising, Russell
    Albu, Jeanine B.
    St-Onge, Marie-Pierre
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2013, 98 (06): : 1433 - 1439
  • [26] FAST-RESPONSE WHOLE-BODY INDIRECT CALORIMETERS FOR INFANTS
    MOON, JK
    JENSEN, CL
    BUTTE, NF
    JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (01) : 476 - 484
  • [27] Perspectives and recommendations regarding standards for ultraviolet-C whole-room disinfection in healthcare
    Kreitenberg A.
    Martinello R.A.
    Journal of Research of the National Institute of Standards and Technology, 2021, 126
  • [28] Toward a Test Protocol for Surface Decontamination Using a Mobile Whole-room UVGI Device†
    Vincent, Richard L.
    Rudnick, Stephen N.
    McDevitt, James J.
    Wallach, Frances R.
    PHOTOCHEMISTRY AND PHOTOBIOLOGY, 2021, 97 (03) : 552 - 559
  • [29] Validation of the doubly labeled water method using integrated cavity output spectroscopy against isotope ratio mass spectrometry and whole-room indirect calorimetry
    Melanson, Edward L.
    Plasqui, Guy
    Wouters, Loek
    Kohrt, Wendy S.
    Swibas, Tracy
    Catenacci, Vicki A.
    Speakman, John R.
    Berman, Elena S.
    FASEB JOURNAL, 2016, 30
  • [30] Perspectives and Recommendations Regarding Standards for Ultraviolet-C Whole-Room Disinfection in Healthcare
    Kreitenberg, Arthur
    Martinello, Richard A.
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2021, 126