Dosimetric Impact of Beam Margin on 3D Conformal Treatment Plan in the Lung Cancer Stereotactic Body Radiotherapy

被引:0
|
作者
Jin, L.
Price, R.
Wang, L.
Fan, J.
Turaka, A.
Buyyounouski, M.
Ma, C.
机构
关键词
D O I
10.1118/1.3468944
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-GGT546
引用
收藏
页数:2
相关论文
共 50 条
  • [21] Dosimetric Evaluation of a Conformal Seven-field Coplanar Technique for Planning Lung Stereotactic Body Radiotherapy
    Richmond, N.
    Green, J.
    Peedell, C.
    Shakespeare, D.
    Walker, C.
    CLINICAL ONCOLOGY, 2012, 24 (01) : E24 - E30
  • [22] Dosimetric Comparison between 3D-Conformal Radiotherapy and Intensity-modulated Radiation Therapy (IMRT) in Stereotactic Body Radiotherapy
    Cao, M.
    Das, I. J.
    Hutchins, K. M.
    Ewing, M. M.
    Fakiris, A. J.
    DesRosiers, C. M.
    Johnstone, P. A. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S694 - S694
  • [23] 3D surface imaging for monitoring intrafraction motion in frameless stereotactic body radiotherapy of lung cancer
    Alderliesten, Tanja
    Sonke, Jan-Jakob
    Betgen, Anja
    van Vliet-Vroegindeweij, Corine
    Remeijer, Peter
    RADIOTHERAPY AND ONCOLOGY, 2012, 105 (02) : 155 - 160
  • [24] Assessment of PTV Margin for Image Guided Stereotactic Body Radiotherapy for Lung Cancer
    Wong, T. P.
    Saini, J.
    Chen, F.
    Rao, M.
    Cao, D.
    Ye, J.
    Afghan, M.
    Wu, J.
    Shepard, D.
    Mehta, V.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S788 - S788
  • [25] DOSIMETRIC COMPARISON OF CONVENTIONAL AND 3D CONFORMAL TREATMENT PLANS FOR PROSTATE CANCER
    Allahverdi, M.
    Vaezzadeh, S. A.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S250 - S250
  • [26] Dosimetric comparison of Acuros XB, AAA, and XVMC in stereotactic body radiotherapy for lung cancer
    Tsuruta, Yusuke
    Nakata, Manabu
    Nakamura, Mitsuhiro
    Matsuo, Yukinori
    Higashimura, Kyoji
    Monzen, Hajime
    Mizowaki, Takashi
    Hiraoka, Masahiro
    MEDICAL PHYSICS, 2014, 41 (08) : 189 - 197
  • [27] Results of 3D conformal radiotherapy in the treatment of localized prostate cancer
    FukunagaJohnson, N
    Sandler, HM
    McLaughlin, PW
    Strawderman, MS
    Grijalva, KH
    Kish, KE
    Lichter, AS
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (02): : 311 - 317
  • [28] Dosimetric Analysis Between Carbon Ion Radiotherapy and Stereotactic Body Radiotherapy in Stage I Lung Cancer
    Ebara, Takeshi
    Shimada, Hirofumi
    Kawamura, Hidemasa
    Shirai, Katsuyuki
    Saito, Jun-Ichi
    Kawashima, Motohiro
    Tashiro, Mutsumi
    Ohno, Tatsuya
    Kanai, Tatsuaki
    Nakano, Takashi
    ANTICANCER RESEARCH, 2014, 34 (09) : 5099 - 5104
  • [29] Dosimetric Verification Using Monte Carlo Calculations for Tissue Heterogeneity-Corrected Conformal Treatment Plans Following RTOG 0813 Dosimetric Criteria for Lung Cancer Stereotactic Body Radiotherapy
    Li, Jun
    Galvin, James
    Harrison, Amy
    Timmerman, Robert
    Yu, Yan
    Xiao, Ying
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (02): : 508 - 513
  • [30] Dosimetric Impact and Evaluation of Different Heterogenity Algorithm in Volumetric Modulated Arc Therapy Plan for Stereotactic Ablative Radiotherapy Lung Treatment with the Flattening Filter Free Beam
    Chung, J.
    Lee, J.
    Kim, Y.
    Kim, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 252 - 252