Development of a near-infrared spectroscopic system for monitoring urine glucose level for the use of long-term home healthcare

被引:1
|
作者
Tanaka, Shinobu [1 ]
Hayakawa, Yuuto [1 ]
Ogawa, Mitsuhiro [1 ]
Yamakoshi, Ken-ichi [1 ]
机构
[1] Kanazawa Univ, Grad Sch Nat Sci & Technol, Kanazawa, Ishikawa 9201192, Japan
关键词
urine glucose level; near-infrared spectroscopy; chemometrics; PLS method; home healthcare;
D O I
10.1117/12.886007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have been developing a new technique for measuring urine glucose concentration using near infrared spectroscopy (NIRS) in conjunction with the Partial Least Square (PLS) method. In the previous study, we reported some results of preliminary experiments for assessing feasibility of this method using a FT-IR spectrometer. In this study, considering practicability of the system, a flow-through cell with the optical path length of 10 mm was newly introduced. Accuracy of the system was verified by the preliminary experiments using urine samples. From the results obtained, it was clearly demonstrated that the present method had a capability of predicting individual urine glucose level with reasonable accuracy (the minimum value of standard error of prediction: SEP = 22.3 mg/dl) and appeared to be a useful means for long-term home health care. However, mean value of SEP obtained by the urine samples from ten subjects was not satisfactorily low (53.7 mg/dl). For improving the accuracy, (1) mechanical stability of the optical system should be improved, (2) the method for normalizing the spectrum should be reconsidered, and (3) the number of subject should be increased.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Development of Urine Glucose Level Monitor for Home Healthcare Using Near Infrared Spectroscopy
    Tanaka, Shinobu
    Ogawa, Mitsuhiro
    Gu, Tao
    Yamakoshi, Ken-ichi
    8TH IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING, VOLS 1 AND 2, 2008, : 1060 - 1062
  • [2] Long-term spectroscopic and near-infrared monitoring of Be/X-ray binaries
    Yan, Jingzhi
    Liu, Qingzhong
    Hang, Hengrong
    CHINESE JOURNAL OF ASTRONOMY AND ASTROPHYSICS, 2006, 6 : 345 - 348
  • [3] In vitro long-term performance study of a near-infrared fluorescence affinity sensor for glucose monitoring
    Ballerstadt, R
    Polak, A
    Beuhler, A
    Frye, J
    BIOSENSORS & BIOELECTRONICS, 2004, 19 (08): : 905 - 914
  • [4] Feasibility study of a urine glucose level monitor for home healthcare using near infrared spectroscopy
    Tanaka, Shinobu
    Motoi, Kosuke
    Nogawa, Masamichi
    Yamakoshi, Takehiro
    Yamakoshi, Ken-Ichi
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 4716 - +
  • [5] Noninvasive blood glucose monitoring by newly developed near-infrared spectroscopic system
    Maruo, K
    Tsurugi, M
    Tamura, M
    Ishii, M
    DIABETES, 2002, 51 : A124 - A124
  • [6] Floating reference position-based correction method for near-infrared spectroscopy in long-term glucose concentration monitoring
    Han, Guang
    Han, Tongshuai
    Xu, Kexin
    Liu, Jin
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (07)
  • [7] Artifact reduction in long-term monitoring of cerebral hemodynamics using near-infrared spectroscopy
    Vinette, Sarah A.
    Dunn, Jeff F.
    Slone, Edward
    Federico, Paolo
    NEUROPHOTONICS, 2015, 2 (02)
  • [8] Short- and long-term near-infrared spectroscopic variability of eruptive protostars from VVV
    Guo, Zhen
    Lucas, P. W.
    Pena, C. Contreras
    Kurtev, R. G.
    Smith, L. C.
    Borissova, J.
    Alonso-Garcia, J.
    Minniti, D.
    Garatti, A. Caratti O.
    Froebrich, D.
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2020, 492 (01) : 294 - 314
  • [9] Spectroscopic Identification in the Middle Region of the Near-Infrared and for Use in Noninvasive Glucose Measurements
    Vargas, J. E.
    Castro, I. D.
    Fonthal, F.
    5TH LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2011): SUSTAINABLE TECHNOLOGIES FOR THE HEALTH OF ALL, PTS 1 AND 2, 2013, 33 (1-2): : 1122 - 1125
  • [10] Development and optimisation of a near-infrared spectroscopic system for glucose quantification in aqueous and intralipid-based samples
    Davison, Nicholas B.
    Gaffney, Christopher J.
    Kerns, Jemma G.
    Zhuang, Qiandong
    ENGINEERING RESEARCH EXPRESS, 2024, 6 (02):