Development and optimisation of a near-infrared spectroscopic system for glucose quantification in aqueous and intralipid-based samples

被引:0
|
作者
Davison, Nicholas B. [1 ]
Gaffney, Christopher J. [1 ]
Kerns, Jemma G. [1 ]
Zhuang, Qiandong [2 ]
机构
[1] Univ Lancaster, Lancaster Med Sch, Lancaster LA1 4AT, England
[2] Univ Lancaster, Phys Dept, Lancaster LA1 4YW, England
来源
ENGINEERING RESEARCH EXPRESS | 2024年 / 6卷 / 02期
关键词
near infrared spectroscopy; glucose monitoring; non-invasive sensing; optical system design; OPTICAL COHERENCE TOMOGRAPHY; BLOOD-GLUCOSE; SCATTERING PROPERTIES; 1ST OVERTONE; HUMAN SKIN; TISSUE; LIGHT; COMBINATION; LIMITATIONS; REGRESSION;
D O I
10.1088/2631-8695/ad4aed
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A non-invasive glucose sensing device could revolutionise diabetes treatment. Near Infrared (NIR) spectroscopy is a promising technology for glucose sensing; however, the design and choice of components for NIR spectroscopy can greatly affect the sensing accuracy. We aimed to develop a NIR absorption spectroscopy system to determine liquid glucose concentrations in the physiological range, by evaluating a range of NIR photodetector components and light sources. Three detection assemblies were tested: (i) a dispersive spectrometer with photodiode array, (ii) a Czerny-Turner monochromator with InGaAs photodiode and (iii) a miniature Fourier Transform Infrared (FTIR) spectrometer. A halogen lamp and NIR globar were trialled as potential light sources. The components were systematically tested by comparing the coefficient of determination and standard error of prediction (SEP) for the same set of aqueous glucose samples through 10 mmol l-1 concentration steps. The Czerny-Turner monochromator with InGaAs photodiode, along with the globar, were identified as the optimal components for the system. A range of concentration steps (1-10 mmol l-1) were scanned to identify the physiologically relevant limit of detection, which was identified as 5 mmol/l for glucose in solution. Spectra were then collected from glucose samples in 10% intralipid suspension in the 10-20 mmol l-1 range and the equivalent concentrations in solution. The SEP was greater for the intralipid samples due to strong scattering. Scattering was dominant above 1300 nm, whilst absorption was dominant below 1300 nm. Although alternative approaches achieve better resolution, our system uses simple and readily-available components and presents a platform for a non-invasive NIR glucose sensing device.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Effect of sample complexity on quantification of analytes in aqueous samples by near-infrared spectroscopy
    Riley, MR
    Arnold, MA
    Murhammer, DW
    APPLIED SPECTROSCOPY, 2000, 54 (02) : 255 - 261
  • [2] TEMPERATURE-INSENSITIVE NEAR-INFRARED SPECTROSCOPIC MEASUREMENT OF GLUCOSE IN AQUEOUS-SOLUTIONS
    HAZEN, KH
    ARNOLD, MA
    SMALL, GW
    APPLIED SPECTROSCOPY, 1994, 48 (04) : 477 - 483
  • [3] Portable Near-Infrared to Near-Infrared Platform for Homogeneous Quantification of Biomarkers in Complex Biological Samples
    Li, Yantao
    Mai, Xiaorui
    Liu, Wenming
    Wang, Feng
    Yan, Shuo
    Lei, Yu
    Chen, Lu
    Mai, Weikang
    Song, Qingwei
    Du, Weidong
    Chen, Xukai
    Ye, Huiru
    Song, Longfei
    Chen, Yu
    Zhao, Lei
    Liu, Zhenwei
    Ding, Weidong
    Yu, Pei
    Jiang, Xue
    Li, Yuyi
    Huang, Jing
    Zhan, Qiuqiang
    Qin, Yiru
    Li, Chenzhong
    Wei, Wei
    Ji, Tianxing
    ACS NANO, 2024, 18 (30) : 19742 - 19755
  • [4] NEAR-INFRARED SPECTROSCOPIC MEASUREMENT OF GLUCOSE IN A PROTEIN MATRIX
    MARQUARDT, LA
    ARNOLD, MA
    SMALL, GW
    ANALYTICAL CHEMISTRY, 1993, 65 (22) : 3271 - 3278
  • [5] Effects of temperature on near-infrared spectroscopic measurement of glucose
    Jung, BJ
    McShane, M
    Rastegar, S
    Cote, GL
    BIOMEDICAL SENSING AND IMAGING TECHNOLOGIES, PROCEEDINGS OF, 1998, 3253 : 41 - 46
  • [6] Noninvasive blood glucose monitoring by newly developed near-infrared spectroscopic system
    Maruo, K
    Tsurugi, M
    Tamura, M
    Ishii, M
    DIABETES, 2002, 51 : A124 - A124
  • [7] Selectivity and Sensitivity of Near-Infrared Spectroscopic Sensing of β-Hydroxybutyrate, Glucose, and Urea in Ternary Aqueous Solutions
    Ye, Maosong
    Arnold, Mark A.
    ANALYTICAL CHEMISTRY, 2021, 93 (13) : 5586 - 5595
  • [8] Near-infrared spectroscopy for glucose detection in aqueous solution
    Attia, Hussein
    Mahnashi, Yaqub
    Qaid, Ammar
    Mohamed, Nadir E.
    Qureshi, Khurram K.
    RESULTS IN OPTICS, 2024, 16
  • [9] NEAR-INFRARED SPECTROSCOPIC STUDIES OF AQUEOUS-ELECTROLYTE SOLUTIONS
    PATIL, KJ
    PATIL, PR
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 1995, 34 (03): : 171 - 175
  • [10] Determination of organic contaminants in aqueous samples by near-infrared spectroscopy
    Ding, Q
    Boyd, BL
    Small, GW
    APPLIED SPECTROSCOPY, 2000, 54 (07) : 1047 - 1054