Backscattered stokes vectors of turbid media: Anisotropy factor and reduced scattering coefficient estimation

被引:1
|
作者
Falconet, Julie [1 ]
Sablong, Raphael [1 ]
Perrin, Emmanuel [1 ]
Jaillon, Franck [1 ]
Saint-Jalmes, Herve [1 ]
机构
[1] Univ Lyon 1, F-69616 Villeurbanne, France
关键词
D O I
10.1109/IEMBS.2007.4352616
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Optical characterization of biological tissues is of real interest to improve medical diagnosis and in particular in the detection of precancerous tissues. The reduced scattering coefficient mu(s)' and the absorption coefficient mu(a) are the most commonly retrieved coefficients. Some methods also allow to obtain the anisotropy factor g, but only few of them are non-invasive. We propose a new non-invasive method allowing the estimation of the anisotropy factor and the reduced scattering coefficient. This method is based on the image analysis of the Q-element of Stokes vector backscattered from the turbid medium. These Q-element images show specific patterns depending on g, and mu(s)' is determined by the size of the patterns. Therefore the use of Fourier Descriptors (FD) on simulated and experimental data, to discriminate the specific geometrical features of the Q-element, enabled us to determine the anisotropy factor and the scattering coefficient.
引用
收藏
页码:1619 / 1622
页数:4
相关论文
共 50 条
  • [41] Determination of the scattering coefficient and the anisotropy factor from laser Doppler spectra of liquids including blood
    Kienle, Alwin
    Patterson, Michael S.
    Ott, Lutz
    Steiner, Rudolf
    1600, (35):
  • [42] Determination of the scattering coefficient and the anisotropy factor from laser Doppler spectra of liquids including blood
    Kienle, A
    Patterson, MS
    Ott, L
    Steiner, R
    APPLIED OPTICS, 1996, 35 (19): : 3404 - 3412
  • [43] Estimation of the scattering coefficients of turbid media using angle-resolved optical frequency-domain imaging
    Desjardins, A. E.
    Vakoc, B. J.
    Bilenca, A.
    Tearney, G. J.
    Bouma, B. E.
    OPTICS LETTERS, 2007, 32 (11) : 1560 - 1562
  • [44] Dehazing cost volume for deep multi-view stereo in scattering media with airlight and scattering coefficient estimation
    Fujimura, Yuki
    Sonogashira, Motoharu
    Iiyama, Masaaki
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2021, 211
  • [45] White light oblique incidence reflectometer for measuring absorption and reduced scattering spectra of tissue-like turbid media
    Marquez, Guillermo
    Wang, Lihong V.
    OPTICS EXPRESS, 1997, 1 (13): : 454 - 460
  • [46] Absorption and reduced scattering coefficient estimation in pigmented human skin tissue by experimental colorimetric fitting
    Cruz Junior, Luismar B.
    Girasol, Carlos E.
    Coltro, Pedro S.
    Guirro, Rinaldo R. J.
    Bachmann, Luciano
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2023, 40 (09) : 1680 - 1685
  • [47] Pressure estimation via measurement of reduced light scattering coefficient by oblique laser incident reflectometry
    Abookasis, David
    Malchi, Daniel
    Robinson, Dror
    Yassin, Mustafa
    JOURNAL OF LASER APPLICATIONS, 2024, 36 (01)
  • [48] Determination of scattering coefficient considering wavelength and absorption dependence of anisotropy factor measured by polarized beam for biological tissues
    Fukutomi, D.
    Ishii, K.
    Awazu, K.
    BIOPHOTONICS JAPAN 2015, 2015, 9792
  • [49] Feasibility study of using reduced scattering coefficient as a monitoring and evaluation factor for tumor microwave ablation therapy
    Qian, Lu
    Zhao, Jinzhe
    Jin, Xiaofei
    Qian, Zhiyu
    Chen, Chunxiao
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS XI, 2021, 11900
  • [50] Quantifying the absorption and reduced scattering coefficients of tissuelike turbid media over a broad spectral range with noncontact Fourier-transform hyperspectral imaging
    Pham, Tuan H.
    Bevilacqua, Frederic
    Spott, Thorsten
    Dam, Jan S.
    Tromberg, Bruce J.
    Andersson-Engels, Stefan
    Applied Optics, 2000, 39 (34): : 6487 - 6497