Computed Tomography Dimensions of the Lacrimal Gland in Normal Caucasian Orbits

被引:37
|
作者
Tamboli, Diana A. [2 ]
Harris, Matheson A. [1 ]
Hogg, Jeffery P. [3 ]
Realini, Tony [1 ]
Sivak-Callcott, Jennifer A. [1 ]
机构
[1] W Virginia Univ, Inst Eye, Morgantown, WV 26505 USA
[2] W Virginia Univ, Sch Med, Morgantown, WV 26505 USA
[3] W Virginia Univ Hosp, Dept Radiol, Morgantown, WV USA
来源
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY | 2011年 / 27卷 / 06期
关键词
D O I
10.1097/IOP.0b013e31821e9f5d
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction: CT is frequently used to assess the lacrimal gland, yet no published reports exist of normal dimensions using this modality. We retrospectively evaluated CT data from normal orbits and measured the lacrimal gland dimensions. Methods: Two-hundred ninety-three consecutive orbital CT scans (586 orbits) of 282 patients were identified. Caucasian patients aged 18 years and older without known orbital disease were included. Traumatized orbits were excluded. All repeated scans were excluded. Length and width of the lacrimal gland were measured in axial and coronal sections with GE Centricity Software. The primary outcome was a descriptive analysis of the distribution of dimensions in normal orbits. A random subset of patient scans was measured independently by observers at different levels of training, and intraclass correlation coefficients (ICCs) were established. Results: Three hundred orbits (150 right orbits and 150 left orbits) of 282 patients were included. Normal distributions occurred with axial and coronal length measurements. Mean (10th and 90th percentiles) lacrimal gland axial length in right orbits was 14.7 mm (10.9 mm and 18.3 mm) and 14.5 mm in left orbits (10.3 mm and 18.3 mm). Coronal length averaged 17.7 mm in right eyes (13.9 mm and 21.8 mm) and 16.9 mm in left eyes (12.8 mm and 20.8 mm). Axial and coronal width showed non-normal distributions. No statistically significant difference in dimensions was found between genders, and a significant inverse linear relation occurred between gland size and age. Agreement was significant among the observers (ICC >0.7). Conclusion: This study presents a normal range of Caucasian lacrimal gland dimensions seen on CT. Lacrimal gland size decreases with age, and no gender difference exists. This range can aid in differentiating diseased and nondiseased lacrimal glands, especially when correlated with physical examination. This may be useful in clinical trials that involve lacrimal gland size.
引用
收藏
页码:453 / 456
页数:4
相关论文
共 50 条
  • [31] DIRECT SAGITTAL SCANS IN COMPUTED TOMOGRAPHY OF ORBITS
    WING, SD
    CT-JOURNAL OF COMPUTED TOMOGRAPHY, 1978, 2 (02): : 109 - 112
  • [32] USE OF CORONAL SCANS FOR COMPUTED TOMOGRAPHY OF ORBITS
    BALERIAUXWAHA, D
    MORTELMANS, LL
    DUPONT, MG
    TERWINGHE, G
    JEANMART, L
    NEURORADIOLOGY, 1977, 14 (02) : 89 - 96
  • [33] Clinical and computed tomographic characteristics of amyloid tumor of the lacrimal gland
    Massry, GG
    Harrison, W
    Hornblass, A
    OPHTHALMOLOGY, 1996, 103 (08) : 1233 - 1236
  • [34] The Caucasian Nasal Septum: An In Vivo Computed Tomography Study
    Daultrey, Charles
    Hardman, John
    Anari, Shahram
    AESTHETIC SURGERY JOURNAL, 2018, 38 (07) : 717 - 722
  • [35] COMPUTED TOMOGRAPHY OF ADRENAL-GLAND
    KARSTAEDT, N
    SAGEL, SS
    STANLEY, RJ
    MELSON, GL
    LEVITT, RG
    RADIOLOGY, 1978, 129 (03) : 723 - 730
  • [36] FINE-STRUCTURE OF HUMAN LACRIMAL GLAND .1. NORMAL GLAND
    ORZALESI, N
    TESTA, F
    RIVA, A
    JOURNAL OF SUBMICROSCOPIC CYTOLOGY, 1971, 3 (03): : 283 - +
  • [37] Can optical coherence tomography be used in lacrimal gland imaging?
    Mrazovac, D.
    Mandic, J. Juri
    Ivkic, P. K.
    Mandic, K.
    Jukic, T.
    ACTA OPHTHALMOLOGICA, 2017, 95
  • [38] COMPUTED TOMOGRAPHY OF NORMAL PANCREAS
    KREEL, L
    HAERTEL, M
    KATZ, D
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (03) : 290 - 299
  • [39] Evaluation of Lacrimal Gland Dimensions with MR Imaging in a Turkish Population Sample
    Totuk, Ozgun Melike Gedar
    Kalkay, Aybike Buse
    Kabadayi, Kerem
    Demir, Mustafa Kemal
    Barut, Cagatay
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2018, 36 (04): : 1431 - 1438
  • [40] Normative lacrimal gland dimensions by magnetic resonance imaging in an Australian cohort
    Rana, Khizar
    Juniat, Valerie
    Patel, Sandy
    Selva, Dinesh
    ORBIT-THE INTERNATIONAL JOURNAL ON ORBITAL DISORDERS-OCULOPLASTIC AND LACRIMAL SURGERY, 2023, 42 (02): : 157 - 160