Adjustable Transobturator Male System (ATOMS) Infection: Causative Organisms and Clinical Profile

被引:4
|
作者
Angulo, Javier C.
Rourke, Keith
Queissert, Fabian
Giammo, Alessandro
Schoenburg, Sandra
Cruz, Francisco
Martins, Francisco E.
Gonsior, Andreas
Gonzalez-Enguita, Carmen
机构
[1] Univ Europea Madrid, Hosp Univ Getafe, Madrid, Spain
[2] Alberta Univ, Edmonton, AB, Canada
[3] Univ Klinikum Munster, Munster, Germany
[4] AOU Citta Salute & Sci Torino, Dept Neuro Urol, CTO Spinal Card Unit, Turin, Italy
[5] Martin Luther Univ Halle Wittenberg, Dept Urol & Kidney Transplantat, Halle, Saale, Germany
[6] Ctr Hosp Sao Joao, Oporto, Portugal
[7] I3S Inst, Fac Med Porto, Porto, Portugal
[8] Ctr Hosp Univ Lisboa Norte, Hosp Santa Maria, Lisbon, Portugal
[9] Univ Leipzig, Klin & Poliklin Urol, Leipzig, Germany
[10] Hosp Univ Fdn Jimenez Diaz, Madrid, Spain
关键词
ARTIFICIAL URINARY SPHINCTER; RISK-FACTORS; INCONTINENCE; BIOFILM; MANAGEMENT; PROSTHESES; CULTURES; OUTCOMES; FAILURE;
D O I
10.1016/j.urology.2021.05.111
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE To evaluate the clinical profile and the organisms producing adjustable transobturator male system (ATOMS) infection in a contemporary series. METHODS Multicenter retrospective study evaluating patients undergoing ATOMS explant for clinical signs of infection from a series of 902 patients treated in 9 academic institutions. Clinical and microbiological data were evaluated. RESULTS Infection presented in 24 patients (2.7%). The median age was 73 +/- 7yrs and the median interval from ATOMS implantation to explant 11 +/- 26.5mo. Infection was diagnosed within 3-months after surgery in 7(29.2%). Scrotal port erosion was present in 6 cases (25%) and systemic symptoms of parenchymatous testicular infection in 2(8.3%). The culture of the periprosthetic fluid was positive in 20(83.3%): 12(50%) Gram-negative bacteria, 9(37.5%) Gram-positive cocci and 1(4.2%) yeast. The most frequent isolates were Enterococcus and Proteus sp. (16.7% each), followed by Pseudomona sp. and S. epidermidis (12.5% each). Methicillin resistant S. aureus was detected only in 1 case (4.2%). Despite the infection 17 patients (70.8%) were satisfied with the implant and 18(75%) received a second device (11 repeated ATOMS and 7 AUS) at a median 9.7 +/- 12.6mo after explant. Limitations include retrospective design and lack of microbiological cultures in ATOMS explanted for non-infective cause. CONCLUSION Infection of a prosthetic device is a disturbing complication. A proportion of patients with ATOMS infection is associated to scrotal port erosion and/or parenchymatous urinary tract infection. Enterococcus and Proteus sp. are the most common organisms producing ATOMS infection and this could have implications for the selection of the most appropriate surgical prophylaxis. (C) 2021 Elsevier Inc.
引用
收藏
页码:120 / 126
页数:7
相关论文
共 50 条
  • [31] ADJUSTABLE TRANSOBTURATOR MALE SYSTEM (ATOMS®) - A NOVEL TREATMENT OPTION IN MEN WITH STRESS URINARY INCONTINENCE: THE FIRST EXPERIENCE IN THE UNITED KINGDOM
    Yang, Bob
    Jelley, Clare
    Foley, Steve
    JOURNAL OF UROLOGY, 2019, 201 (04): : E662 - E662
  • [32] Compression or obstruction: Prospective analysis of the function of the Adjustable Transobturator Male System (ATOMS) based on pre-and postoperative urodynamic data
    Queissert, Fabian
    Bruecher, Benedict
    Ruiz, Sonja
    Virseda-Chamorro, Miguel
    Schrader, Andres J.
    Angulo, Javier C.
    CUAJ-CANADIAN UROLOGICAL ASSOCIATION JOURNAL, 2022, 16 (05): : E256 - E260
  • [33] MULTI-CENTERED ASSESSMENT OF FACTORS ASSOCIATED WITH EXPLANTATION OF 3RD GENERATION ADJUSTABLE TRANSOBTURATOR MALE SYSTEM (ATOMS)
    Naud, Elizabeth
    Nadeau, Genevieve
    Tu, Le-Mai
    Doiron, Christopher
    Steele, Stephen
    Herschorn, Sender
    Locke, Jennifer
    Maciejewski, Conrad
    Dwyer, Neil
    Campeau, Lysanne
    Carlson, Kevin
    Rourke, Keith
    JOURNAL OF UROLOGY, 2022, 207 (05): : E541 - E541
  • [34] Adjustable transobturator male system (ATOMS) for post-prostatectomy incontinence: Outcomes from a tertiary center over 10 years
    Roth, I
    Beisland, C.
    Juliebo-Jones, P.
    Hjelle, K. M.
    SCANDINAVIAN JOURNAL OF UROLOGY, 2023, 58 : 6 - 7
  • [35] ANALYZING OUTCOMES OF THE ADJUSTABLE TRANSOBTURATOR MALE SYSTEM (ATOMS) FOR POST-PROSTATECTOMY INCONTINENCE: RESULTS OF A SINGLE-CENTER STUDY
    Farag, Samuel
    Pelletier, Joanie
    Ismail, Salima
    Le Mai Tu
    JOURNAL OF UROLOGY, 2022, 207 (05): : E886 - E886
  • [36] ADJUSTABLE TRANSOBTURATOR MALE SYSTEM (ATOMS) FOR MALE POST-PROSTATECTOMY STRESS URINARY INCONTINENCE: INITIAL MULTI-CENTRE EXPERIENCE IN HONG KONG
    Man, C.
    Sk, C.
    Sy, C.
    Hy, C.
    C, W.
    Sm, H.
    Cw, M.
    INTERNATIONAL JOURNAL OF UROLOGY, 2012, 19 : 332 - 332
  • [37] Adjustable Transobturator Male System (ATOMS) for Male Post-prostatectomy Stress Urinary Incontinence: Initial Multi-centre Experience in Hong Kong
    Law, M.
    Chu, S.
    Chan, S.
    Cheung, H.
    Fan, C.
    Hou, S.
    Man, C.
    UROLOGY, 2012, 80 (03) : S40 - S40
  • [38] Systematic review and meta-analysis comparing Adjustable Transobturator Male System (ATOMS) and male Readjustment Mechanical External (REMEEX) system for post-prostatectomy incontinence
    Angulo, Javier C.
    Ruiz, Sonia
    Lozano, Martin
    Arance, Ignacio
    Virseda, Miguel
    Lora, David
    WORLD JOURNAL OF UROLOGY, 2021, 39 (04) : 1083 - 1092
  • [39] Systematic review and meta-analysis comparing Adjustable Transobturator Male System (ATOMS) and male Readjustment Mechanical External (REMEEX) system for post-prostatectomy incontinence
    Javier C. Angulo
    Sonia Ruiz
    Martín Lozano
    Ignacio Arance
    Miguel Virseda
    David Lora
    World Journal of Urology, 2021, 39 : 1083 - 1092
  • [40] Adjustable male sling (ATOMS® System) for male stress urinary incontinence
    Pun, C. T.
    Cheng, C. H.
    Li, M. L.
    Chu, S. K.
    Man, C. W.
    BJU INTERNATIONAL, 2017, 119 : 15 - 15