Locked volar plating for complex distal radius fractures: maintaining radial length

被引:4
|
作者
Jeudy, J. [1 ]
Pernin, J. [1 ]
Cronier, R. [1 ]
Talha, A. [1 ]
Massin, R. [1 ]
机构
[1] CHU Angers, Dept Chirurg Osseuse, F-49100 Angers, France
关键词
comminutive fracture; radius fracture; internal fixation;
D O I
10.1016/S0035-1040(07)90325-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose of the study Maintaining radial length, likely to be the main challenge in the treatment of complex distal radius fractures, is necessary for complete grip-strength and pro-supination range recovery. In spite of frequent secondary displacements, bridging external-fixation has remained the reference method, either isolated or in association with additional percutaneous pins or volar plating. Also, there seems to be a relation between algodystrophy and the duration of traction applied on the radio-carpal joint. Fixed-angle volar plating offers the advantage of maintaining the reduction until fracture healing, without bridging the joint. Material and methods In a prospective study, forty-three consecutive fractures of the distal radius with a positivated ulnar variance were treated with open reduction and fixed-angle volar plating. Results were assessed with special attention to the radial length and angulation obtained and maintained throughout treatment, based on repeated measurements of the uInar variance and radial angulation in the first six months postoperatively. Results The correction of the uInar variance was maintained until complete recovery, independently of initial metaphyseal comminution, and of the amount of radial length gained at reduction. Only 3 patients lost more than 1 mm of radial length after reduction. The posterior tilt of the distal radial epiphysis was incompletely reduced in 13 cases, whereas reduction was partially lost in 6 elderly osteoporotic female patients. There was 8 articular malunions, all of them less than 2 mm. Secondary displacements were found to be related to a deficient locking technique. Eight patients developed an algodystropy. The risk factors for algodystrophy were articular malunion, associated posterior pining, and associated lesions of the ipsilateral upper limb. Conclusion Provided that the locking technique was correct, this type of fixation appeared efficient in maintaining the radial length in complex fractures of the distal radius. The main challenge remains the reduction of displaced articular fractures. Based on these results, it is not possible to conclude that this method is superior to external fixation.
引用
收藏
页码:435 / 443
页数:9
相关论文
共 50 条
  • [31] High rate of complications following volar plating of distal radius fractures
    Knudsen, Roland
    Bahadirov, Zafar
    Damborg, Frank
    DANISH MEDICAL JOURNAL, 2014, 61 (10):
  • [32] The Detection of Prominent Hardware in Volar Locked Plating of Distal Radius Fractures: Intraoperative Fluoroscopy Versus Computed Tomography
    Ganesh, Devin
    Service, Ben
    Zirgibel, Brian
    Koval, Kenneth
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (11) : 618 - 621
  • [33] Effect of Screw Length in Volar Plating for Intra-Articular Distal Radius Fractures: A Biomechanical Study
    Hong, Thomas S.
    Lee, Daniel J.
    Jahani, Babak
    Broz, Kaitlyn S.
    Aboytes, Donald A.
    Tang, Simon
    Demartini, Stephen
    Brogan, David M.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2024, 49 (12): : 1186 - 1195
  • [34] Anatomy of Lister's Tubercle: Implications for Volar Locked Plating of the Distal Radius
    Laane, Charlotte L. E.
    Raasveld, Floris V.
    de Klerk, Huub H.
    Weigel, Daniel T.
    Pratap, Jayanth S.
    Chen, Neal C.
    Eberlin, Kyle R.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2024,
  • [35] The Effect of Plate Design on the Flexor Pollicis Longus Tendon After Volar Locked Plating of Distal Radial Fractures
    Stepan, Jeffrey G.
    Marshall, Danielle C.
    Wessel, Lauren E.
    Endo, Yoshimi
    Miller, Theodore T.
    Sacks, Hayley A.
    Weiland, Andrew J.
    Fufa, Duretti T.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (17): : 1586 - 1592
  • [36] Treatment of unstable distal radial fractures with the volar locking plating system
    Chung, Kevin C.
    Watt, Andrew J.
    Kotsis, Sandra V.
    Margaliot, Zvi
    Haase, Steven C.
    Kim, Myra
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (12): : 2687 - 2694
  • [37] Variable-Angle Locking Screw Volar Plating of Distal Radius Fractures
    Park, Jung H.
    Hagopian, Jennifer
    Ilyas, Asif M.
    HAND CLINICS, 2010, 26 (03) : 373 - +
  • [38] The radio-volar double plating technique for comminuted distal fractures of the radius
    Erling, Christoph
    Jacobi, Matthias
    Wahl, Peter
    Kohut, Georges
    SWISS MEDICAL WEEKLY, 2012, 142 : S15 - S15
  • [39] Comparison of a New Intramedullary Scaffold to Volar Plating for Treatment of Distal Radius Fractures
    van Kampen, Robert J.
    Thoreson, Andrew R.
    Knutson, Nathan J.
    Hale, Joseph E.
    Moran, Steven. L.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2013, 27 (09) : 535 - 541
  • [40] Return to Yoga Rates Are High After Volar Plating of Distal Radius Fractures
    Goyal, Nitin
    Tsai, Andrew G.
    Li, Jefferson
    Wysocki, Robert W.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2021, 16 (01): : 110 - 114