Locked volar plating for complex distal radius fractures: maintaining radial length

被引:4
|
作者
Jeudy, J. [1 ]
Pernin, J. [1 ]
Cronier, R. [1 ]
Talha, A. [1 ]
Massin, R. [1 ]
机构
[1] CHU Angers, Dept Chirurg Osseuse, F-49100 Angers, France
关键词
comminutive fracture; radius fracture; internal fixation;
D O I
10.1016/S0035-1040(07)90325-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose of the study Maintaining radial length, likely to be the main challenge in the treatment of complex distal radius fractures, is necessary for complete grip-strength and pro-supination range recovery. In spite of frequent secondary displacements, bridging external-fixation has remained the reference method, either isolated or in association with additional percutaneous pins or volar plating. Also, there seems to be a relation between algodystrophy and the duration of traction applied on the radio-carpal joint. Fixed-angle volar plating offers the advantage of maintaining the reduction until fracture healing, without bridging the joint. Material and methods In a prospective study, forty-three consecutive fractures of the distal radius with a positivated ulnar variance were treated with open reduction and fixed-angle volar plating. Results were assessed with special attention to the radial length and angulation obtained and maintained throughout treatment, based on repeated measurements of the uInar variance and radial angulation in the first six months postoperatively. Results The correction of the uInar variance was maintained until complete recovery, independently of initial metaphyseal comminution, and of the amount of radial length gained at reduction. Only 3 patients lost more than 1 mm of radial length after reduction. The posterior tilt of the distal radial epiphysis was incompletely reduced in 13 cases, whereas reduction was partially lost in 6 elderly osteoporotic female patients. There was 8 articular malunions, all of them less than 2 mm. Secondary displacements were found to be related to a deficient locking technique. Eight patients developed an algodystropy. The risk factors for algodystrophy were articular malunion, associated posterior pining, and associated lesions of the ipsilateral upper limb. Conclusion Provided that the locking technique was correct, this type of fixation appeared efficient in maintaining the radial length in complex fractures of the distal radius. The main challenge remains the reduction of displaced articular fractures. Based on these results, it is not possible to conclude that this method is superior to external fixation.
引用
收藏
页码:435 / 443
页数:9
相关论文
共 50 条
  • [1] Radiographic Outcomes of Volar Locked Plating for Distal Radius Fractures
    Mignemi, Megan E.
    Byram, Ian R.
    Wolfe, Carmen C.
    Fan, Kang-Hsien
    Koehler, Elizabeth A.
    Block, John J.
    Jordanov, Martin I.
    Watson, Jeffry T.
    Weikert, Douglas R.
    Lee, Donald H.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (01): : 40 - 48
  • [2] Locked volar plating for complex distal radius fractures: Patient reported outcomes and satisfaction
    Anakwe, R. E.
    Khan, L. A. K.
    Cook, R. E.
    McEachan, J. E.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2010, 5
  • [3] Locked volar plating for complex distal radius fractures: Patient reported outcomes and satisfaction
    RE Anakwe
    LAK Khan
    RE Cook
    JE McEachan
    Journal of Orthopaedic Surgery and Research, 5
  • [4] Volar plating of distal radius fractures using a locked anatomically contoured plate
    Peter D. Gallacher
    R. Gilbert
    S. Memon
    I. G. Bhoora
    European Journal of Orthopaedic Surgery & Traumatology, 2010, 20 : 11 - 15
  • [5] Volar plating of distal radius fractures using a locked anatomically contoured plate
    Gallacher, Peter D.
    Gilbert, R.
    Memon, S.
    Bhoora, I. G.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2010, 20 (01): : 11 - 15
  • [6] Flexor tendon injuries following locked volar plating of distal radius fractures
    Cross, Andrew W.
    Schmidt, Christopher C.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (02): : 164 - 167
  • [7] Complications of volar plating of distal radius fractures
    Rampold, Michele
    Marsico, Salvatore
    ACTA ORTHOPAEDICA BELGICA, 2007, 73 (06): : 714 - 719
  • [8] Volar Plating as a Treatment for Distal Radius Fractures
    Orbay, Jorge
    Shah, Ajul
    White, Brian D.
    Patel, Anup
    Vernon, Lauren
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2016, 4 (09)
  • [9] Locked volar plating for unstable distal radial fractures: Clinical and radiological outcomes
    Knight, Dominique
    Hajducka, Carol
    Will, Elizabeth
    McQueen, Margaret
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (02): : 184 - 189
  • [10] Volar locking plating for distal radial fractures
    Voigt, C.
    Plesz, A.
    Jensen, G.
    Katthagen, C.
    Lill, H.
    CHIRURG, 2012, 83 (05): : 463 - 471