Increased Long-Term Mortality in Patients with Cardiovascular Implantable Electronic Device Infections

被引:81
|
作者
Sohail, Muhammad Rizwan [1 ,2 ]
Henrikson, Charles A. [3 ]
Braid-Forbes, Mary Jo [4 ]
Forbes, Kevin F. [4 ,5 ]
Lerner, Daniel J. [6 ]
机构
[1] Mayo Clin, Coll Med, Div Infect Dis, Rochester, MN 55905 USA
[2] Mayo Clin, Coll Med, Div Cardiovasc Dis, Rochester, MN 55905 USA
[3] Oregon Hlth & Sci Univ, Knight Cardiovasc Inst, Portland, OR 97201 USA
[4] Braid Forbes Hlth Res, Silver Spring, MD USA
[5] Catholic Univ Amer, Washington, DC 20064 USA
[6] TYRX Inc, Monmouth Jct, NJ USA
来源
关键词
cardiovascular implantable electronic device; infection; mortality; pacemaker; implantable cardioverter defibrillator; cardiac resynchronization therapy; MANAGEMENT; PACEMAKER;
D O I
10.1111/pace.12518
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundDevice infection is associated with increased mortality in patients receiving cardiovascular implantable electronic device (CIED) therapy. However, long-term mortality associated with CIED infections has not been systematically analyzed in larger studies. This study sought to determine the long-term mortality associated with CIED infection in a large cohort of Medicare beneficiaries. MethodsWe used a retrospective study design to analyze 3-year mortality in 200,219 Medicare fee-for-service patients admitted for CIED generator implantation, replacement, or revision between January 1, 2007 and December 31, 2007. Multivariate analysis adjusting for age, sex, race, and 28 comorbidities was performed to determine the relative risk (RR) of death in the 12 quarters following CIED infection. ResultsPatients with CIED infection, compared to device recipients without infection, had increased mortality that persisted for at least 3 years after the admission quarter for all device types: pacemakers (PMs: 53.8% vs 33%; P < 0.001), implantable cardioverter defibrillator (ICD: 47.7% vs 31.6%; P < 0.001), and cardiac resynchronization therapy-defibrillator (CRT-D: 50.8% vs 36.5%; P < 0.001). After adjusting for patient demographics and comorbidities, significantly increased RR of death following CIED infection persisted for at least 3 years following PM infection, and for at least 2 years with single- and dual-chamber ICD infection. ConclusionsCIED recipients who develop device infection have increased, device-dependent, long-term mortality even after successful treatment of infection. The etiology of this persistent increased risk of death associated with CIED infection is unknown and merits further investigation.
引用
收藏
页码:231 / 239
页数:9
相关论文
共 50 条
  • [11] Procalcitonin in cardiovascular implantable electronic device infections
    Sedehi, D.
    Siddiqi, N.
    Shrestha, N.
    Agarwal, S.
    Tarakji, K.
    Wazni, O.
    Menon, V.
    EUROPEAN HEART JOURNAL, 2014, 35 : 100 - 100
  • [12] Cardiac Implantable Electronic Device Infections; Long-Term Outcome after Extraction and Antibiotic Treatment
    Hornsten, Jonas
    Axelsson, Louise
    Westling, Katarina
    INFECTIOUS DISEASE REPORTS, 2021, 13 (03) : 627 - 635
  • [13] IMPACT OF TIMING OF DEVICE REMOVAL ON OUTCOMES IN PATIENTS WITH CARDIOVASCULAR IMPLANTABLE ELECTRONIC DEVICE INFECTIONS
    Cummings, Shenae
    Bensler, James Michael
    Hall, Michael E.
    Hernandez, Gabriel Antonio
    McMullan, Michael R.
    Sohail, Muhammad
    Garrigos, Zerelda E.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 141 - 141
  • [14] Comparison of Mortality in Women Versus Men With Infections Involving Cardiovascular Implantable Electronic Device
    Sohail, M. Rizwan
    Henrikson, Charles A.
    Braid-Forbes, Mary Jo
    Forbes, Kevin F.
    Lerner, Daniel J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (09): : 1403 - 1409
  • [15] Differences of Mortality Rates between Pocket and Nonpocket Cardiovascular Implantable Electronic Device Infections
    Lee, Dong Heun
    Gracely, Edward J.
    Aleem, Sarah Y.
    Kutalek, Steven P.
    Vielemeyer, Ole
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (12): : 1456 - 1463
  • [16] Cardiovascular Implantable Electronic Device Infections A Contemporary Review
    Bielick, Catherine G.
    Arnold, Christopher J.
    Chu, Vivian H.
    INFECTIOUS DISEASE CLINICS OF NORTH AMERICA, 2024, 38 (04) : 673 - 691
  • [17] Microbiology and Pathogenesis of Cardiovascular Implantable Electronic Device Infections
    Nagpal, Avish
    Baddour, Larry M.
    Sohail, Muhammad R.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (02): : 433 - 441
  • [18] Contemporary management of cardiovascular implantable electronic device infections
    Sohail, Muhammad R.
    Sultan, Omer W.
    Raza, Sania S.
    EXPERT REVIEW OF ANTI-INFECTIVE THERAPY, 2010, 8 (07) : 831 - 839
  • [19] Long-term monitoring of arrhythmias with cardiovascular implantable electronic devices in patients with cardiac sarcoidosis
    Bakker, Annelies
    Mathijssen, Harold
    Dorland, Galina
    Balt, Jippe C.
    van Dijk, Vincent F.
    Veltkamp, Marcel
    Akdim, Fatima C.
    Grutters, Jan C.
    Post, Martijn
    HEART RHYTHM, 2022, 19 (03) : 352 - 360
  • [20] Long-Term Outcomes of Cardiovascular Implantable Electronic Devices in Patients with Staphylococcus aureus Bacteremia
    Obeid, Karam M.
    Szpunar, Susan
    Khatib, Riad
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (08): : 961 - 965