Dosimetric properties of equivalent-quality flattening filter-free (FFF) and flattened photon beams of Versa HD linear accelerator

被引:8
|
作者
Meshram, Mukesh N. [1 ]
Pramanik, Srimanta [1 ]
Ranjith, C. P. [1 ]
Gopal, Saravana K. [1 ]
Dobhal, Rishabh [1 ]
机构
[1] CIMS Hosp Pvt Ltd, Ahmadabad 380060, Gujarat, India
来源
关键词
equivalent-quality beam; flattening filter free; dosimetric properties; photon beam data; Versa HD linac; FREE CLINICAL ACCELERATOR; MONTE-CARLO; COLLIMATOR; THERAPY;
D O I
10.1120/jacmp.v17i3.6173
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study presents the basic dosimetric properties of photon beams of a Versa HD linear accelerator (linac), which is capable of delivering flattening filter-free (FFF) beams with a beam quality equivalent to the corresponding flattened beams based on comprehensive beam data measurement. The analyzed data included the PDDs, profiles, penumbra, out-of-field doses, surface doses, output factors, head and phantom scatter factors, and MLC transmissions for both FFF and flattened beams of 6 MV and 10 MV energy from an Elekta Versa HD linac. The 6MVFFF and 10MVFFF beams had an equivalent mean energy to the flattened beams and showed less PDD variations with the field sizes. Compared with their corresponding flattened beams, D-max was deeper for FFF beams for all field sizes; the ionization ratio variations with the field size were lower for FFF beams; the out-of-field doses were lower and the penumbras were sharper for the FFF beams; the off-axis profile variations with the depths were lesser for the FFF beams. Further, the 6MVFFF and 10MVFFF beams had 35.7% and 40.9% less variations in output factor with the field size, respectively. The collimator exchange effect was reduced in the FFF mode. The head scatter factor showed 59.1% and 73.6% less variations, on average, for the 6MVFFF and 10MVFFF beams, respectively; the variations in the phantom scatter factor were also smaller. The surface doses for all beams increased linearly with the field size. The 6MVFFF and 10MVFFF beams had higher surface doses than the corresponding flattened beams for field sizes of up to 10x10cm(2) but had lower surface doses for larger fields. Both FFF beams had lower average MLC transmissions than the flattened beams. The finding that the FFF beams were of equivalent quality to the corresponding flattened beams indicates a significant difference from the data on unmatched FFF beams.
引用
下载
收藏
页码:358 / 370
页数:13
相关论文
共 50 条
  • [31] Flattening filter free beams from TrueBeam and Versa HD units: Evaluation of the parameters for quality assurance
    Fogliata, Antonella
    Fleckenstein, Jens
    Schneider, Frank
    Pachoud, Marc
    Ghandour, Sarah
    Krauss, Harald
    Reggiori, Giacomo
    Stravato, Antonella
    Lohr, Frank
    Scorsetti, Marta
    Cozzi, Luca
    MEDICAL PHYSICS, 2016, 43 (01) : 205 - 212
  • [32] Evaluation of IMRT and VMAT for Head-and-Neck Cancer With Flattening Filter-free (FFF) Beams
    Wu, Q.
    Yoo, S.
    Das, S.
    Yin, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S863 - S863
  • [33] Dosimetric properties of a flattening filter-free 6-MV photon beam: A Monte Carlo study
    Mesbahi A.
    Mehnati P.
    Keshtkar A.
    Farajollahi A.
    Radiation Medicine, 2007, 25 (7): : 315 - 324
  • [34] Evaluation of dosimetric properties of 6 & 10 MV photon beams from a liner accelerator with no flattening filter
    Pearson, D.
    Parsai, E.
    Feldmeier, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2099 - 2099
  • [35] Dosimetric comparison of flattened and flattening filter-free beams for liver stereotactic body irradiation in deep inspiration breath hold, and free breathing conditions
    Munirathinam, N.
    Pawaskar, P. N.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (02) : 169 - 174
  • [36] Comparison of Head Scatters in Flattening-Filter-Free and Flattened Photon Beams
    Chen, Y.
    Shih, R.
    Afghan, M.
    Gopal, A.
    Chen, H.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [37] Impact of Dosimetric Parameters on Interplay Effects in 6 MV Flattening Filter-Free Photon Beams to Treat Lung Cancer
    Poolnapol, Vanida
    Sanghangthum, Taweap
    Keawsamur, Mintra
    JOURNAL OF MEDICAL PHYSICS, 2022, 47 (01) : 20 - 26
  • [38] A Monte Carlo study of a flattening filter-free linear accelerator verified with measurements
    Dalaryd, Marten
    Kragl, Gabriele
    Ceberg, Crister
    Georg, Dietmar
    McClean, Brendan
    af Wetterstedt, Sacha
    Wieslander, Elinore
    Knoos, Tommy
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (23): : 7333 - 7344
  • [39] Monte Carlo study on a flattening filter-free 18-MV photon beam of a medical linear accelerator
    Mesbahi, Asghar
    Nejad, Farshad Seyed
    RADIATION MEDICINE, 2008, 26 (06): : 331 - 336
  • [40] Monte Carlo study of photon fields from a flattening filter-free clinical accelerator
    Vassiliev, ON
    Titt, U
    Kry, SF
    Pönisch, F
    Gillin, MT
    Mohan, R
    MEDICAL PHYSICS, 2006, 33 (04) : 820 - 827