Reference right atrial function determined by steady-state free precession cardiovascular magnetic resonance

被引:34
|
作者
Sievers, Burkhard [1 ]
Addo, Marvin
Breuckmann, Frank
Barkhausen, Joerg
Erbel, Raimund
机构
[1] Univ Duisburg Essen, W German Heart Ctr, Dept Cardiol, Essen, Germany
[2] Univ Cologne, Dept Cardiol, Cologne, Germany
[3] Univ Duisburg Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, Essen, Germany
关键词
cardiovascular magnetic resonance; right atrial function; short axis method; area-length method;
D O I
10.1080/10976640701545552
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. There is agreement that measurements of atrial volumes and election fraction (EF) are superior to atrial diameters for accurate determination of atrial size, follow up studies and prognosis. However, reference values for right atrial volumes and EF for cardiovascular magnetic resonance (CMR) have not been established but are crucial to identify patients with impaired right atrial function. Methods and Results: Atrial function was studied in 70 healthy subjects (52 +/- 16 years, 38 male) with both the standard short axis method (SA) and the area-length method (AL) using steady-state free precession gradient-echo cine imaging (SSFP). Intraobserver, interobserver (n = 70) and interstudy (n = 10) variability was assessed for both methods. Maximal volumes, minimal volumes and EF for SA and AL were 101.0 +/- 30.2 mL, 50.3 +/- 19 mL and 47.2 +/- 8.3%, and 103.2 +/- 32.6 mL, 50.8 +/- 20.2 mL and 51.4 +/- 9.2%, respectively. Maximal volumes, minimal volumes and EF were higher with AL than with SA (mean difference: 2.2 +/- 4.6 mL, 3.5 +/- 3.5 mL and 2.8 +/- 2.8%, respectively). Atrial function measurements were not related to gender (p >= 0.387) and age (rho <= 0.16) with either method. Intraobserver, interobserver and interstudy variability for volumes and EF was lower for SA compared to AL, with narrower limits of agreement. Analysis was faster with AL than with SA (62 +/- 18 s versus 7 +/- 2 minutes). Conclusion: Normal ranges for right atrial function vary significantly between methods. AL is faster, but less reproducible than SA. Appropriate reference ranges should be used to differentiate normal from abnormal,right atrial function.
引用
收藏
页码:807 / 814
页数:8
相关论文
共 50 条
  • [21] Fast and fully automatic calibration of frequency offset for balanced steady-state free precession cardiovascular magnetic resonance at 3.0 Tesla
    Yu-Wei Tang
    Teng-Yi Huang
    Wen-Chau Wu
    Journal of Cardiovascular Magnetic Resonance, 15
  • [22] Fast and fully automatic calibration of frequency offset for balanced steady-state free precession cardiovascular magnetic resonance at 3.0 Tesla
    Tang, Yu-Wei
    Huang, Teng-Yi
    Wu, Wen-Chau
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
  • [23] Free-Breathing Steady-State Free Precession Cine Cardiac Magnetic Resonance with Respiratory Navigator Gating
    Moghari, Mehdi H.
    Komarlu, Rukmini
    Annese, David
    Geva, Tal
    Powell, Andrew J.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (04) : 1555 - 1561
  • [24] Lineshape of Magnetic Resonance and its Effects on Free Induction Decay and Steady-State Free Precession Signal Formation
    Ziener, C. H.
    Uhrig, M.
    Kampf, T.
    Sturm, V. J. F.
    Kurz, F. T.
    Heiland, S.
    Bendszus, M.
    Pham, M.
    Jakob, P. M.
    Schlemmer, H-P
    Buschle, L. R.
    CONCEPTS IN MAGNETIC RESONANCE PART A, 2020, 2020
  • [25] Reference Values for Pediatric Atrial Volumes Assessed by Steady-State Free-Precession Magnetic Resonance Imaging Using Monoplane and Biplane Area-Length Methods
    Voges, Inga
    Caliebe, Amke
    Hinz, Sophia
    Grazioli, Simona Boroni
    Gabbert, Daniel Dominik
    Wegner, Philip
    Uebing, Anselm Sebastian
    Daubeney, Piers E. F.
    Pennell, Dudley J.
    Krupickova, Sylvia
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (02) : 532 - 542
  • [26] Gadolinium free cardiovascular magnetic resonance with 2-point Cine balanced steady state free precession
    Tori A. Stromp
    Steve W. Leung
    Kristin N. Andres
    Linyuan Jing
    Brandon K. Fornwalt
    Richard J. Charnigo
    Vincent L. Sorrell
    Moriel H. Vandsburger
    Journal of Cardiovascular Magnetic Resonance, 17
  • [27] MOVING-REFERENCE-FRAME IMAGING UNDER STEADY-STATE FREE PRECESSION
    TYSZKA, M
    HAWKES, RC
    HALL, LD
    JOURNAL OF MAGNETIC RESONANCE SERIES B, 1993, 101 (02): : 158 - 164
  • [28] Gadolinium free cardiovascular magnetic resonance with 2-point Cine balanced steady state free precession
    Stromp, Tori A.
    Leung, Steve W.
    Andres, Kristin N.
    Jing, Linyuan
    Fornwalt, Brandon K.
    Charnigo, Richard J.
    Sorrell, Vincent L.
    Vandsburger, Moriel H.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [29] Clinical Evaluation of Left Ventricular Diastolic Function Using Phase-contrast Cine Cardiovascular Magnetic Resonance Imaging: A Comparison With Steady-state Free Precession Cine Cardiovascular Magnetic Resonance Imaging and Echocardiography
    Komi, Shotaro
    Inoue, Yusuke
    Hata, Hirofumi
    Miyatake, Hiroki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (01) : 56 - 63
  • [30] MISSING PULSE STEADY-STATE FREE PRECESSION
    PATZ, S
    WONG, STS
    ROOS, MS
    MAGNETIC RESONANCE IN MEDICINE, 1989, 10 (02) : 194 - 209