Reference right atrial function determined by steady-state free precession cardiovascular magnetic resonance

被引:34
|
作者
Sievers, Burkhard [1 ]
Addo, Marvin
Breuckmann, Frank
Barkhausen, Joerg
Erbel, Raimund
机构
[1] Univ Duisburg Essen, W German Heart Ctr, Dept Cardiol, Essen, Germany
[2] Univ Cologne, Dept Cardiol, Cologne, Germany
[3] Univ Duisburg Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, Essen, Germany
关键词
cardiovascular magnetic resonance; right atrial function; short axis method; area-length method;
D O I
10.1080/10976640701545552
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. There is agreement that measurements of atrial volumes and election fraction (EF) are superior to atrial diameters for accurate determination of atrial size, follow up studies and prognosis. However, reference values for right atrial volumes and EF for cardiovascular magnetic resonance (CMR) have not been established but are crucial to identify patients with impaired right atrial function. Methods and Results: Atrial function was studied in 70 healthy subjects (52 +/- 16 years, 38 male) with both the standard short axis method (SA) and the area-length method (AL) using steady-state free precession gradient-echo cine imaging (SSFP). Intraobserver, interobserver (n = 70) and interstudy (n = 10) variability was assessed for both methods. Maximal volumes, minimal volumes and EF for SA and AL were 101.0 +/- 30.2 mL, 50.3 +/- 19 mL and 47.2 +/- 8.3%, and 103.2 +/- 32.6 mL, 50.8 +/- 20.2 mL and 51.4 +/- 9.2%, respectively. Maximal volumes, minimal volumes and EF were higher with AL than with SA (mean difference: 2.2 +/- 4.6 mL, 3.5 +/- 3.5 mL and 2.8 +/- 2.8%, respectively). Atrial function measurements were not related to gender (p >= 0.387) and age (rho <= 0.16) with either method. Intraobserver, interobserver and interstudy variability for volumes and EF was lower for SA compared to AL, with narrower limits of agreement. Analysis was faster with AL than with SA (62 +/- 18 s versus 7 +/- 2 minutes). Conclusion: Normal ranges for right atrial function vary significantly between methods. AL is faster, but less reproducible than SA. Appropriate reference ranges should be used to differentiate normal from abnormal,right atrial function.
引用
收藏
页码:807 / 814
页数:8
相关论文
共 50 条
  • [1] Reference right atrial dimensions and volume estimation by steady state free precession cardiovascular magnetic resonance
    Alicia M Maceira
    Juan Cosín-Sales
    Michael Roughton
    Sanjay K Prasad
    Dudley J Pennell
    Journal of Cardiovascular Magnetic Resonance, 15
  • [2] Reference right atrial dimensions and volume estimation by steady state free precession cardiovascular magnetic resonance
    Maceira, Alicia M.
    Cosin-Sales, Juan
    Roughton, Michael
    Prasad, Sanjay K.
    Pennell, Dudley J.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
  • [3] Reference left atrial dimensions and volumes by steady state free precession cardiovascular magnetic resonance
    Alicia M Maceira
    Juan Cosín-Sales
    Michael Roughton
    Sanjay K Prasad
    Dudley J Pennell
    Journal of Cardiovascular Magnetic Resonance, 12
  • [4] Reference left atrial dimensions and volumes by steady state free precession cardiovascular magnetic resonance
    Maceira, Alicia M.
    Cosin-Sales, Juan
    Roughton, Michael
    Prasad, Sanjay K.
    Pennell, Dudley J.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2010, 12
  • [5] STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE
    CARR, HY
    PHYSICAL REVIEW, 1958, 112 (05): : 1693 - 1701
  • [6] STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE
    CARR, HY
    PHYSICAL REVIEW LETTERS, 1958, 1 (11) : 429 - 430
  • [7] Normal values for paediatric atrial volumes assessed by steady-state free-precession cardiovascular magnetic resonance
    Voges, I.
    Hinz, S.
    Caliebe, A.
    Gracioli, S. Boroni
    Wage, R.
    Gabbert, D.
    Uebing, A.
    Krupickova, S.
    EUROPEAN HEART JOURNAL, 2021, 42 : 1601 - 1601
  • [8] Reference right ventricular systolic and diastolic function normalized to age, gender and body surface area from steady-state free precession cardiovascular magnetic resonance
    Maceira, Alicia M.
    Prasad, Sanjay K.
    Khan, Mohammed
    Pennell, Dudley J.
    EUROPEAN HEART JOURNAL, 2006, 27 (23) : 2879 - 2888
  • [9] Editorial for "Reference Values for Pediatric Atrial Volumes Assessed by Steady-State Free-Precession Magnetic Resonance Imaging"
    Schoennagel, Bjoern P.
    Fischer, Roland
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (02) : 543 - 544
  • [10] Atrial function after ablation procedure in patients with chronic atrial fibrillation using steady-state free precession magnetic resonance imaging
    Fleck, Tatjana
    Wolf, Florian
    Bader, Till
    Lehner, Raimund
    Aigner, Clemens
    Stix, Guenter
    Wolner, Ernst
    Wisser, Wilfried
    ANNALS OF THORACIC SURGERY, 2007, 84 (05): : 1600 - 1604