Numerical Model for Water-Cooled EGR Cooler Performance Improvement

被引:0
|
作者
Kim, Hak Min [1 ]
Yeom, Jeong Kuk [1 ]
机构
[1] Dong A Univ, Dept Mech Engn, Busan, South Korea
关键词
Computational Fluid Dynamics; Cooled EGR; Diesel Engine; EGR Cooler; Exhaust Gas Recirculation; HEAT-TRANSFER CHARACTERISTICS; FLOW;
D O I
10.3795/KSME-B.2020.44.1.061
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
An EGR system, which is a technology to reduce exhaust gas, can effectively reduce soot and NOx when the exhaust gas temperature is lowered, and it is necessary to improve the cooling performance of the EGR cooler. A numerical analysis was conducted to improve the cooling performance. The numerical analysis program was ANSYS CFX. The improved EGR cooler was designed based on the numerical analysis results of the original EGR cooler. The temperature data for the modified EGR cooler and original EGR cooler were compared. Consequently, it was confirmed that the cooling performance of the EGR cooler was improved.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
  • [1] Numerical Study of the Optimal Shape Design of a Water-cooled EGR Cooler
    Kim, Hak Min
    Yeom, Jeong Kuk
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2019, 43 (07) : 463 - 469
  • [2] Improvement of heat transfer performance and unmatched characteristics of a water-cooled carbon dioxide gas cooler
    Song, Xia
    Zhang, Lun
    Lu, Daxiong
    Shi, Junye
    Chen, Jiangping
    APPLIED THERMAL ENGINEERING, 2021, 197
  • [3] Effects of lubricating oil on thermal performance of water-cooled carbon dioxide gas cooler
    Dai, Baomin
    Li, Minxia
    Dang, Chaobin
    Yu, Wenfang
    Ma, Yitai
    APPLIED THERMAL ENGINEERING, 2015, 80 : 288 - 300
  • [4] Numerical Simulation and Analysis of Water-cooled Radiator Performance for Traction Converter
    Zhang Long-yan
    Hu Jun-ping
    2013 FIFTH INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION (ICMTMA 2013), 2013, : 737 - 742
  • [5] Numerical Study on the Performance of a Natural Draft Cooling Tower With Water-Cooled Collectors
    Zhao, Shun-An
    Song, Xiao-Jun
    Guo, Fu-Min
    Feng, Jing
    Zhang, Dong-Wen
    HEAT TRANSFER ENGINEERING, 2017, 38 (11-12) : 1054 - 1062
  • [6] Improvement of water-cooled electric arc furnace electrodes
    Zoellner, Dieter
    Unger, Klaus-Dieter
    Cisar, Horst
    MPT. Metallurgical plant and technology, 1988, 11 (06): : 24 - 25
  • [7] Experimental study on water-cooled thermoelectric cooler for CPU under severe environment
    Hu, H. M.
    Ge, T. S.
    Dai, Y. J.
    Wang, R. Z.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 62 : 30 - 38
  • [8] Water-Cooled to Water-Cooled Chiller Replacement Saves Big
    Cheuk, Kim Tang
    Liu, Clara Tianqi
    Wong, Regina Y. Y.
    Ho, Jeremy C. Y.
    Chan, Cary
    ASHRAE JOURNAL, 2022, 64 : 42 - 44
  • [9] Water-Cooled to Water-Cooled Chiller Replacement Saves Big
    Cheuk, Kim Tang
    Liu, Clara Tianqi
    Wong, Regina Y.Y.
    Ho, Jeremy C.Y.
    Chan, Cary
    ASHRAE Journal, 2022, 64 (06) : 42 - 44
  • [10] Experimental and numerical study of water-cooled datacom equipment
    Douchet, Fabien
    Nortershauser, David
    Le Masson, Stepahne
    Glouannec, Patrick
    APPLIED THERMAL ENGINEERING, 2015, 84 : 350 - 359