Analytical method for determination of dinitropyrenes using gas chromatography-high-resolution mass spectrometry

被引:1
|
作者
Nakao, Teruyuki [1 ]
Aozasa, Osamu [1 ]
Ohta, Souichi [1 ]
Miyata, Hideaki [1 ]
机构
[1] Setsunan Univ, Fac Pharmaceut Sci, Osaka 5730101, Japan
关键词
dinitropyrene; GC-HRMS; electron impact; derivatization; standard reference material; diesel exhaust particulate;
D O I
10.1016/j.chroma.2007.04.046
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A gas chromatography-high-resolution mass spectrometry method has been developed for the determination of dinitropyrenes (DNPs). DNPs were reduced to the corresponding diaminopyrenes with sodium hydrosulfide, and the reduced DNPs were derivatized with N-metbylbis(trifluoroacetamide). The sensitivity of this method was up to 10 times that of high-performance liquid chromatography with fluorescence detection. The detection limits for 1,3-, 1,6-, and 1,8-DNPs were in the 0.90-1.1 pg range. The concentrations were corrected with a correction factor determined from the recovery of an internal standard. The recovery of deuterium-labeled 6-nitrochrysene was at least 87%. This new method was utilized for quantitative determination of DNPs in Standard Reference Material (SRM) 1975 available from the US National Institute of Standards and Technology. Three DNP isomers were measured in SRM 1975 at 0.571-1.59 mu g/g. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:352 / 357
页数:6
相关论文
共 50 条
  • [41] Determination of atmospheric organochlorine pesticides using isotope dilution high resolution gas chromatography/high-resolution mass spectrometry
    Zhang Jingxing
    Zheng Xiaoyan
    Li, Tan
    Liu Jinbin
    Yu Haibin
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2021, 39 (05) : 541 - 551
  • [42] Chloride-attachment atmospheric pressure photoionisation for the determination of short-chain chlorinated paraffins by gas chromatography-high-resolution mass spectrometry
    Ayala-Cabrera, J. F.
    Galceran, M. T.
    Moyano, E.
    Santos, F. J.
    ANALYTICA CHIMICA ACTA, 2021, 1172
  • [43] Application of Stir-Bar Sorptive Extraction for Determination of Organic Pollutants in Snow by Thermal Desorption Gas Chromatography-High-Resolution Mass Spectrometry
    Latkin, T. B.
    Kosyakov, D. S.
    Ul'yanovskii, N. V.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 79 (13) : 1923 - 1934
  • [44] Trace level determination of 9-tetrahydrocannabinol in a perfume using liquid chromatography high resolution tandem mass spectrometry and gas chromatography mass spectrometry
    Thalhamer, Bernhard
    Himmelsbach, Markus
    Buchberger, Wolfgang
    FLAVOUR AND FRAGRANCE JOURNAL, 2017, 32 (01) : 46 - 53
  • [45] Urine analysis of 28 designer benzodiazepines by liquid chromatography-high-resolution mass spectrometry
    Bergstrand, Madeleine Pettersson
    Beck, Olof
    Helander, Anders
    CLINICAL MASS SPECTROMETRY, 2018, 10 : 25 - 32
  • [46] Investigation of pharmaceuticals and illicit drugs in waters by liquid chromatography-high-resolution mass spectrometry
    Hernandez, F.
    Ibanez, M.
    Bade, R.
    Bijlsma, L.
    Sancho, J. V.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 63 : 140 - 157
  • [47] Strategy for Comprehensive Identification of Acylcarnitines Based on Liquid Chromatography-High-Resolution Mass Spectrometry
    Yu, Di
    Zhou, Lina
    Xuan, Qiuhui
    Wang, Lichao
    Zhao, Xinjie
    Lu, Xin
    Xu, Guowang
    ANALYTICAL CHEMISTRY, 2018, 90 (09) : 5712 - 5718
  • [48] Advances in liquid chromatography-high-resolution mass spectrometry for quantitative and qualitative environmental analysis
    Acena, Jaume
    Stampachiacchiere, Serena
    Perez, Sandra
    Barcelo, Damia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (21) : 6289 - 6299
  • [49] Validation of a liquid chromatography-high-resolution mass spectrometry method to quantify peptide-related impurities in teriparatide
    Weisz, Daniel A.
    Rogstad, Sarah M.
    Zeng, Kui
    Pang, Eric
    Geerlof-Vidavsky, Ilan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2025, 255
  • [50] DETERMINATION OF SUSPECTED TOXIC IMPURITIES IN FIREMASTER FF-1 AND FIREMASTER BP-6 BY HIGH-RESOLUTION GAS CHROMATOGRAPHY-HIGH-RESOLUTION MASS-SPECTROMETRY
    TONDEUR, Y
    HASS, JR
    HARVAN, DJ
    ALBRO, PW
    MCKINNEY, JD
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1984, 32 (02) : 406 - 410