Eight-channel parallel transmit-receive system for 7 T MRI with optically controlled and monitored on-coil current-mode RF amplifiers

被引:5
|
作者
Gudino, Natalia [1 ]
de Zwart, Jacco A. [1 ]
Duyn, Jeff H. [1 ]
机构
[1] NINDS, Lab Funct & Mol Imaging, NIH, Bldg 36,Rm 4D04, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
high-field MRI; parallel transmission; RF amplifiers; CURRENT AMPLITUDE; GLOBAL SAR; LOCAL SAR; ARRAY; POWER; EXCITATION; EFFICIENCY; PHASE;
D O I
10.1002/mrm.28392
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To demonstrate a practical implementation of an eight-channel parallel-transmit system for brain imaging at 7 T based on on-coil amplifier technology. Methods An eight-channel parallel transmit-receive system was built with optimized on-coil switch-mode current RF power amplifiers. The amplifiers were optically controlled from an eight-channel interface that was connected to a 7 T MRI scanner. The interface also optically received a down-converted version of the coil current sensed in each amplifier for monitoring and feedback adjustments. Results Each on-coil amplifier delivered more than 100 W peak power and provided enough amplifier decoupling (<-15 dB) for the implemented eight-channel array configuration. Phantom and human images were acquired to demonstrate practical operation of this new technology in a 7 T MRI scanner. Conclusion Further development and improvement of previously demonstrated on-coil technology led to successful implementation of an eight-channel parallel-transmit system able to deliver strongB(1)fields for typical brain imaging applications. This is an important step forward toward implementation of on-coil RF amplification for high-field MRI.
引用
收藏
页码:3494 / 3501
页数:8
相关论文
共 11 条
  • [1] Eight-channel transmit/receive body MRI coil at 3T
    Vernickel, P.
    Roeschmann, P.
    Findeklee, C.
    Luedeke, K.-M.
    Leussler, Ch.
    Overwag, J.
    Katscher, U.
    Graesslin, I.
    Schuenemann, K.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (02) : 381 - 389
  • [2] An eight-channel transmit/receive multipurpose coil for musculoskeletal MR imaging at 7 T
    Kraff, Oliver
    Bitz, Andreas K.
    Dammann, Philipp
    Ladd, Susanne C.
    Ladd, Mark E.
    Quick, Harald H.
    MEDICAL PHYSICS, 2010, 37 (12) : 6368 - 6376
  • [3] A dedicated eight-channel receive RF coil array for monkey brain MRI at 9.4 T
    Li, Mingyan
    Li, Yu
    Jin, Jin
    Yang, Zhengyi
    Zhang, Baogui
    Liu, Yanyan
    Song, Ming
    Freakly, Craig
    Weber, Ewald
    Liu, Feng
    Jiang, Tianzi
    Crozier, Stuart
    NMR IN BIOMEDICINE, 2020, 33 (10)
  • [4] An eight-channel T/R head coil for parallel transmit MRI at 3T using ultra-low output impedance amplifiers
    Moody, Katherine Lynn
    Hollingsworth, Neal A.
    Zhao, Feng
    Nielsen, Jon-Fredrik
    Noll, Douglas C.
    Wright, Steven M.
    McDougall, Mary Preston
    JOURNAL OF MAGNETIC RESONANCE, 2014, 246 : 62 - 68
  • [5] Optically Controlled Switch-Mode Current-Source Amplifiers for On-Coil Implementation in High-Field Parallel Transmission
    Gudino, Natalia
    Duan, Qi
    de Zwart, Jacco A.
    Murphy-Boesch, Joe
    Dodd, Stephen J.
    Merkle, Hellmut
    van Gelderen, Peter
    Duyn, Jeff H.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (01) : 340 - 349
  • [6] Field Distribution and Coupling Investigation of an Eight-Channel RF Coil Consisting of Different Dipole Coil Elements for 7 T MRI
    Chen, Zhichao
    Solbach, Klaus
    Erni, Daniel
    Rennings, Andreas
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (06) : 1297 - 1304
  • [7] Eight-Channel Phased Array RF Coils Design for 3T Parallel MRI System
    Basari
    Rahardjo, Eko Tjipto
    Zulkifli, Fitri Yuli
    2015 IEEE 4TH ASIA-PACIFIC CONFERENCE ON ANTENNAS AND PROPAGATION (APCAP), 2015, : 56 - 57
  • [8] Open design eight-channel transmit/receive coil for high-resolution and real-time ankle imaging at 7 T
    Orzada, Stephan
    Bitz, Andreas K.
    Schaefer, Lena C.
    Ladd, Susanne C.
    Ladd, Mark E.
    Maderwald, Stefan
    MEDICAL PHYSICS, 2011, 38 (03) : 1162 - 1167
  • [9] An eight-channel transmit/receive array of TE01 mode high permittivity ceramic resonators for human imaging at 7 T
    Aussenhofer, S. A.
    Webb, A. G.
    JOURNAL OF MAGNETIC RESONANCE, 2014, 243 : 122 - 129
  • [10] Design and comparison of two eight-channel transmit/receive radiofrequency arrays for in vivo rodent imaging on a 7 T human whole-body MRI system
    Orzada, Stephan
    Maderwald, Stefan
    Goericke, Sophia L.
    Parohl, Nina
    Ladd, Susanne C.
    Ladd, Mark E.
    Quick, Harald H.
    MEDICAL PHYSICS, 2010, 37 (05) : 2225 - 2232