Quantification of fat in the posterior sacroiliac joint region applying a semi-automated segmentation method

被引:5
|
作者
Poilliot, Amelie [1 ]
Tannock, Murray [2 ]
Zhang, Ming [1 ]
Zwirner, Johann [1 ]
Hammer, Niels [3 ,4 ,5 ,6 ]
机构
[1] Univ Otago, Dept Anat, Dunedin, New Zealand
[2] Univ Otago, Dept Comp Sci, Dunedin, New Zealand
[3] Med Univ Graz, Dept Clin & Macroscop Anat, Graz, Austria
[4] Univ Leipzig, Dept Orthoped & Trauma Surg, Leipzig, Germany
[5] Fraunhofer IWU, Dresden, Germany
[6] Tech Univ Chemnitz, Dept Machine Tool Design & Forming Technol, Chemnitz, Germany
关键词
Sacroiliac joint; MATLAB; Semi-automated method; Fat quantification; Computed tomography; Hounsfield units; VOLUME; MUSCLE; MRI;
D O I
10.1016/j.cmpb.2020.105386
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: Fat within the posterior sacroiliac joint region (PSIJ) is thought to compensate for the incongruent surfaces of the sacrum and ilium posteriorly. Knowledge on the presence of fat in the SIJ could provide useful information about joint physiology and clinical kinematic implications of its presence. This study aimed at quantifying fat within the PSIJ, using a semi-automated method, and to compare the results to a manual segmentation method based on data from frozen cadaveric sections and computed tomography (CT). The results may provide a quicker and more objective method for fat volume quantification. Methods: Seventy-eight cadaveric hemipelves were used. Frozen sections were obtained and photographed and CT data obtained from subsamples. A MATLAB routine was deployed to assess fat in the serial sections and CT scans, using masks derived from color thresholds and Hounsfield units, respectively. Regions of interest were created to isolate the PSIJ region before fat volume was computed. A Friedman test was used for the comparison between all masks and the manual method, a Kruskall-Wallis test for comparing the CT results with all masks and the manual method and Bland-Altman plots were used to express the result differences of these methods. Results: PSIJ fat volume averaged 3.9 +/- 2.2, 4.9 +/- 2.5, 3.7 +/- 2.3 and 7.2 +/- 7.3 cm(3) for masks 1 (fat mask), 2 (no-fat mask), 3 ('control' fat mask) and CT, respectively. All masks and the CT fat volume were significantly different to the manual segmentation method (p<0.01). Mask 2 differed significantly from masks 1 and 3 (both p<0.01). Bland-Altman plots yielded differences in the measurements between the various methods. Conclusions: Manual segmentation of PSIJ fat volume may result in a relative underestimation of the total fat compared to semi-automated or CT-based methods, as fat might not be sufficiently distinguished from surrounding structures. However, the CT-based method resulted in vastly higher variation in the results and warrants further study. The semi-automated approach to quantify fat based on color thresholds presented here is more investigator-independent, time efficient and applicable to CT scans, which provides opportunity to use this technique on various tissue types in vivo. (C) 2020 Published by Elsevier B.V.
引用
下载
收藏
页数:9
相关论文
共 50 条
  • [21] A SIMPLE SEMI-AUTOMATED METHOD OF IMMUNOELECTROPHORESIS
    CAWLEY, LP
    SCHNEIDE.D
    EBERHARD.L
    HARROUCH, J
    MILLSAP, G
    CLINICA CHIMICA ACTA, 1965, 12 (01) : 105 - &
  • [22] Semi-automated quantification of living cells with internalized nanostructures
    Michael Bogdan Margineanu
    Khachatur Julfakyan
    Christoph Sommer
    Jose Efrain Perez
    Maria Fernanda Contreras
    Niveen Khashab
    Jürgen Kosel
    Timothy Ravasi
    Journal of Nanobiotechnology, 14
  • [23] Semi-automated quantification of living cells with internalized nanostructures
    Margineanu, Michael Bogdan
    Julfakyan, Khachatur
    Sommer, Christoph
    Perez, Jose Efrain
    Contreras, Maria Fernanda
    Khashab, Niveen
    Kosel, Juergen
    Ravasi, Timothy
    JOURNAL OF NANOBIOTECHNOLOGY, 2016, 14
  • [24] Benchmarking Human Performance in Semi-Automated Image Segmentation
    Eramian, Mark
    Power, Christopher
    Rau, Stephen
    Khandelwal, Pulkit
    INTERACTING WITH COMPUTERS, 2020, 32 (03) : 233 - 245
  • [25] VESCA: Semi-Automated Segmentation of Cerebral Vasculature in Angiograms
    Stier, Noah
    Garduno, Cristopher
    Sheth, Sunil
    Duckwiler, Gary
    Saver, Jeffrey
    Liebeskind, David
    Scalzo, Fabien
    STROKE, 2016, 47
  • [26] Semi-automated Intracranial Aneurysm Segmentation and Neck Detection
    Le, Nam H.
    Samaniego, Edgar A.
    Raghuram, Ashrita
    Sanchez, Sebastian
    Zhang, Honghai
    Sonka, Milan
    MEDICAL IMAGING 2022: IMAGE PROCESSING, 2022, 12032
  • [27] COMPARISON OF SEMI-AUTOMATED AND MANUAL SEGMENTATION OF KNEE CARTILAGE
    Yu, H. J.
    Chang, A.
    Fukuda, Y.
    Terada, Y.
    Nozaki, T.
    Yoshioka, H.
    OSTEOARTHRITIS AND CARTILAGE, 2016, 24 : S311 - S311
  • [28] Improving microPET quantification: semi-automated volumes of interest
    Nandi, Ayon
    Kuwabara, Hiroto
    Ye, Weiguo
    Kumar, Anil
    Chun, Kyungah
    Valentine, Heather
    Blue, Mary
    Wong, Dean F.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2012, 32 : S189 - S190
  • [29] Semi-automated segmentation of dual echo MR images
    Petropoulos, H
    Sibbitt, WL
    Brooks, WM
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 602 - 604
  • [30] Semi-Automated Quantification of Finger Joint Space Narrowing Using Tomosynthesis in Patients with Rheumatoid Arthritis
    Ichikawa, Shota
    Kamishima, Tamotsu
    Sutherland, Kenneth
    Kasahara, Hideki
    Shimizu, Yuka
    Fujimori, Motoshi
    Yasojima, Nobutoshi
    Ono, Yohei
    Kaneda, Takahiko
    Koike, Takao
    JOURNAL OF DIGITAL IMAGING, 2017, 30 (03) : 369 - 375