Tactile display for 2-D and 3-D shape expression using SMA micro actuators

被引:19
|
作者
Matsunaga, T [1 ]
Totsu, K [1 ]
Esashi, M [1 ]
Haga, Y [1 ]
机构
[1] TUBERO, Sendai, Miyagi, Japan
关键词
tactile display; SMA actuator; Braille; magnetic latch;
D O I
10.1109/MMB.2005.1548391
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tactile display which displays character and graphic information dynamically from computer by making pins array up and down has been developed. Shape Memory Alloy (SMA) micro-coil actuators contract and make the pins up and down when an electrical current is supplied. Magnetic material tube is attached to each pin and a permanent magnet fixes position of the pins up or down. Electrical consumption is low because the current is supplied only when the pins move. A 2-D tactile display which has 100 (10 x 10) pins array has been developed and successfully operated. The tactile information were displayed sequentially every 0.3 second and the pins were latched at 0.1 N by magnetic force. The pins are arranged at a pitch of 2.5 mm and move 2 mm up and down individually. In order to present the tactile information accurately, narrower pin pitch of the tactile display is preferable. A module for tactile display with a pin pitch of 1.27 mm has been fabricated and successfully operated. A multi-step magnetic latch has been developed for a 3-D tactile display. By using these mechanisms, large displacement and accurate positioning of the pin for 3-D expression can be realized.
引用
收藏
页码:88 / 91
页数:4
相关论文
共 50 条
  • [41] Electric-field-driven LC lens for 3-D/2-D autostereoscopic display
    Hong, HyungKi
    Jung, SungMin
    Lee, ByungJu
    Shin, HyunHo
    JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2009, 17 (05) : 399 - 406
  • [42] Design of GRIN Liquid Crystal Lens for Autostereoscopic 2-D/3-D Switchable Display
    Zhang, Caijian
    Tang, Xianzhu
    Chen, Chaoping
    Huang, Gaofeng
    Cui, Hongqing
    Si, Bingyu
    Chung, Te Chen
    Jen, Tean Sen
    LIQUID CRYSTALS AND RELATED MATERIALS II, 2012, 181-182 : 301 - 304
  • [43] 2-D and 3-D shape optimization using mesh velocities to integrate analytical sensitivities with associative CAD
    Lindby, T
    Santos, JLT
    STRUCTURAL OPTIMIZATION, 1997, 13 (04) : 213 - 222
  • [44] 2-D and 3-D shape optimization using mesh velocities to integrate analytical sensitivities with associative CAD
    Instituto Superior Tecnico, Lisboa, Portugal
    Struct Opt, 4 (213-222):
  • [45] 2-D and 3-D shape optimization using mesh velocities to integrate analytical sensitivities with associative CAD
    T. Lindby
    J. L. T. Santos
    Structural optimization, 1997, 13 : 213 - 222
  • [46] Enhancing 2-D tactile picture design from knowledge of 3-D haptic object recognition
    Thompson, Leanne J.
    Chronicle, Edward P.
    Collins, Alan F.
    EUROPEAN PSYCHOLOGIST, 2006, 11 (02) : 110 - 118
  • [47] 2-D MR Spectroscopy Combined with 2-D/3-D Spatial Encoding
    Thomas, M. Albert
    Iqbal, Zohaib
    Sarma, Manoj K.
    Nagarajan, Rajakumar
    Macey, Paul M.
    Huda, Amir
    EMAGRES, 2016, 5 (01): : 1039 - 1060
  • [48] 3-D measurement of 2-D jet by 3-D 3-C SPIV
    Ninomiya, Nao
    Tanaka, Yukihisa
    Sotome, Satoshi
    Eda, Masahide
    Watanabe, Atsushi
    JOURNAL OF VISUALIZATION, 2019, 22 (02) : 305 - 312
  • [49] 3-D measurement of 2-D jet by 3-D 3-C SPIV
    Nao Ninomiya
    Yukihisa Tanaka
    Satoshi Sotome
    Masahide Eda
    Atsushi Watanabe
    Journal of Visualization, 2019, 22 : 305 - 312
  • [50] Micro 3-D opto-tactile measuring system
    Ji, Guijun
    Schwenke, H.
    Trapet, E.
    Luo, Zhen
    Chen, Feng
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2000, 21 (01): : 95 - 97