Near-infrared spectroscopic measurement of myoglobin oxygen saturation in the presence of hemoglobin using partial least-squares analysis

被引:40
|
作者
Schenkman, KA [1 ]
Marble, DR
Feigl, EO
Burns, DH
机构
[1] Univ Washington, Dept Anesthesiol, Seattle, WA 98195 USA
[2] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[3] Univ Washington, Dept Physiol, Seattle, WA 98195 USA
[4] McGill Univ, Dept Chem, Quebec City, PQ H3A 2K6, Canada
关键词
hemoglobin; myoglobin; optical spectroscopy; oxygenation; partial least-squares; near-infrared;
D O I
10.1366/0003702991946532
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Myoglobin is an important intracellular protein found in cardiac and skeletal muscle. It is involved in the intracellular transport of oxygen from the cell membrane to the mitochondria where oxidative phosphorylation takes place, The optical absorbance characteristics of myoglobin are similar to those of hemoglobin in the near-infrared spectral region, Distinguishing spectral information of myoglobin from hemoglobin should allow for determination of intracellular oxygen availability in muscle. Partial least-squares analysis is used in this report to determine the oxygen saturation of myoglobin, in the presence of hemoglobin, in vitro. Studies were performed with the use of both transmission and reflectance spectroscopic techniques, Transmission spectra of myoglobin solutions were determined with varying degrees of oxygen saturation achieved by deoxygenating the solution using E. coli. Calibration spectral data sets were developed with the use of varying concentrations of hemoglobin interference, and with varying degrees of myoglobin oxygen saturation. Reflectance spectra were obtained from myoglobin and hemoglobin solutions containing a scattering agent to mimic muscle tissue conditions. Predicted myoglobin saturation values were within 2% of the known saturation values from the use of this analysis, Partial least-squares analysis allows for accurate prediction of myoglobin oxygen saturation in the presence of hemoglobin from either transmission of reflectance near-infrared spectra.
引用
收藏
页码:325 / 331
页数:7
相关论文
共 50 条
  • [1] Improved myoglobin saturation measurement made by partial least-squares analysis of optical reflectance spectra
    Schenkman, KA
    Ciesielski, WA
    APPLIED SPECTROSCOPY, 2002, 56 (09) : 1215 - 1221
  • [2] MIDINFRARED SPECTRA FROM NEAR-INFRARED SPECTRA USING PARTIAL LEAST-SQUARES
    LEW, R
    BALKE, ST
    APPLIED SPECTROSCOPY, 1993, 47 (11) : 1747 - 1750
  • [3] Nondestructive Discrimination of Pharmaceutical Preparations Using Near-Infrared Spectroscopy and Partial Least-Squares Discriminant Analysis
    Chen, Hui
    Lin, Zan
    Tan, Chao
    ANALYTICAL LETTERS, 2018, 51 (04) : 564 - 574
  • [4] An improved boosting partial least squares method for near-infrared spectroscopic quantitative analysis
    Shao, Xueguang
    Bian, Xihui
    Cai, Wensheng
    ANALYTICA CHIMICA ACTA, 2010, 666 (1-2) : 32 - 37
  • [5] Application of partial least-squares regression to near-infrared reflectance spectroscopic determination of shive content in flax
    Sohn, M
    Barton, FE
    Morrison, WH
    Archibald, DD
    APPLIED SPECTROSCOPY, 2003, 57 (05) : 551 - 556
  • [6] POPULATION STRUCTURING OF NEAR-INFRARED SPECTRA AND MODIFIED PARTIAL LEAST-SQUARES REGRESSION
    SHENK, JS
    WESTERHAUS, MO
    CROP SCIENCE, 1991, 31 (06) : 1548 - 1555
  • [7] Boosting partial least-squares discriminant analysis with application to near infrared spectroscopic tea variety discrimination
    Tan, Shi-Miao
    Luo, Rui-Min
    Zhou, Yan-Ping
    Xu, Hui
    Song, Dan-Dan
    Ze, Tan
    Yang, Tian-Ming
    Nie, Yan
    JOURNAL OF CHEMOMETRICS, 2012, 26 (01) : 34 - 39
  • [8] Determination of glycated hemoglobin using near-infrared spectroscopy combined with equidistant combination partial least squares
    Han, Yun
    Chen, Jiemei
    Pan, Tao
    Liu, Guisong
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2015, 145 : 84 - 92
  • [9] Assessment of partial least-squares calibration and wavelength selection for complex near-infrared spectra
    McShane, MJ
    Cote, GL
    Spiegelman, CH
    APPLIED SPECTROSCOPY, 1998, 52 (06) : 878 - 884
  • [10] Band assignment of near-infrared spectra of milk by use of partial least-squares regression
    Sasic, S
    Ozaki, Y
    APPLIED SPECTROSCOPY, 2000, 54 (09) : 1327 - 1338