Quasi-monochromatic x-rays for diagnostic radiology

被引:13
|
作者
Baldelli, P [1 ]
Taibi, A [1 ]
Tuffanelli, A [1 ]
Gambaccini, M [1 ]
机构
[1] Univ Ferrara, Dipartmento Fis, I-44100 Ferrara, Italy
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2003年 / 48卷 / 22期
关键词
SYNCHROTRON-RADIATION; MOSAIC CRYSTALS; MAMMOGRAPHY; RADIOGRAPHY; ARRAY;
D O I
10.1088/0031-9155/48/22/003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Monochromatic x-ray beams are desirable in various fields of diagnostic radiology; in fact a reduction of the dose and an enhancement of the contrast could be achieved. In this work two different methods to monochromatize x-ray beams produced by conventional tubes have been compared. In the first one the beam is obtained via Bragg diffraction on mosaic crystal and in the second one by attenuating the polychromatic beam with aluminium filters. We have simulated quasi-monochromatic x-ray spectra by setting suitable values of Bragg's angle to obtain beams tuned to 20, 30, 40 and 50 keV with the SHADOW code, an x-ray tracing program designed to study the propagation and the interaction of a photon beam through an optical system. We have validated such a program by comparing some calculated data with measurements carried out on an experimental apparatus. Attenuated polychromatic x-ray spectra have been simulated by setting appropriate values of aluminium filters and potential with the SPECTRUM PROCESSOR, the software version of the Catalogue of Spectral Data for Diagnostic X-Rays, which provides radiographic x-ray spectra that can be attenuated with several material filters. The relation between the energy resolution and the flux as a function of the mean energy has been investigated and results have been compared. Results show that quasi-monochromatic x-ray beams produced via Bragg diffraction exhibit, for a given mean energy and energy resolution, a higher total flux compared to attenuated spectra.
引用
收藏
页码:3653 / 3665
页数:13
相关论文
共 50 条
  • [41] A COMPARISON OF QUASI-MONOCHROMATIC EXCITATION METHODS IN X-RAY SPECTROMETRY
    BROLL, N
    ANALUSIS, 1987, 15 (07) : 325 - 332
  • [42] Advantages of quasi-monochromatic X-ray sources in absorption mammography
    Oliva, P.
    Golosio, B.
    Stumbo, S.
    Carpinelli, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 608 (01): : S106 - S108
  • [43] DIAGNOSTIC X-RAYS IN PREGNANCY
    SAAFAN, STA
    DARWISH, DH
    LANCET, 1976, 1 (7959): : 596 - 596
  • [44] DIAGNOSTIC X-RAYS IN PREGNANCY
    HOBBINS, JC
    TAYLOR, KJW
    LANCET, 1976, 1 (7962): : 739 - 739
  • [45] DIAGNOSTIC X-RAYS IN PREGNANCY
    RUSSELL, JGB
    LANCET, 1976, 1 (7957): : 478 - 479
  • [46] X-RAY-FLUORESCENCE ANALYSIS WITH MONOCHROMATIC X-RAYS
    KOTERA, M
    WITTRY, DB
    JOURNAL DE PHYSIQUE, 1984, 45 (NC-2): : 281 - 284
  • [47] Energy currents for quasi-monochromatic fields
    Mokhun, I. I.
    Galushko, Yu. K.
    Kharitonova, Ye. S.
    Viktorovskaya, Ju. Yu
    UKRAINIAN JOURNAL OF PHYSICAL OPTICS, 2012, 13 (03) : 151 - 157
  • [48] Quasi-monochromatic cerium flash angiography
    Sato, E
    Germer, R
    Tanaka, E
    Mori, H
    Kawai, T
    Ichimaru, T
    Sato, S
    Ojima, H
    Takayama, K
    Ido, H
    26th International Congress on High Speed Photography and Photonics, 2005, 5580 : 146 - 152
  • [49] Novel practical quasi-monochromatic depolarizer
    Chi, Hao
    Gao, Jun
    Xu, Senlu
    Guangxue Xuebao/Acta Optica Sinica, 1997, 17 (08): : 1097 - 1102
  • [50] LYOT DEPOLARIZER IN QUASI-MONOCHROMATIC LIGHT
    RICHTER, PH
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1979, 69 (03) : 460 - 463