Establishment of a semi-automated pathogen DNA isolation from whole blood and comparison with commercially available kits

被引:24
|
作者
Wiesinger-Mayr, Herbert [1 ]
Jordana-Lluch, Elena [2 ]
Martro, Elisa [2 ,3 ]
Schoenthaler, Silvia [1 ]
Noehammer, Christa [1 ]
机构
[1] AIT Austrian Inst Technol GmbH, A-1190 Vienna, Austria
[2] Autonomous Univ Barcelona, Germans Trias & Pujol Univ Hosp, Microbiol Serv, Badalona, Spain
[3] Biomed Res Ctr Network Epidemiol & Publ Hlth CIBE, Barcelona, Spain
关键词
DNA isolation; Bloodstream infection; Molecular diagnostics; Sepsis; Automation; BACTERIAL PATHOGENS; MICROBIAL DNA; PCR; MICROARRAY; IDENTIFICATION; BACTEREMIA; EXTRACTION; DIAGNOSIS; SAMPLES;
D O I
10.1016/j.mimet.2011.03.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Molecular methods for bacterial pathogen identification are gaining increased importance in routine clinical diagnostic laboratories. Achieving reliable results using DNA based technologies is strongly dependent on pre-analytical processes including isolation of target cells and their DNA of high quality and purity. In this study a fast and semi-automated method was established for bacterial DNA isolation from whole blood samples and compared to different commercially available kits: Looxster, MolYsis kit, SeptiFast DNA isolation method and standard EasyMAG protocol. The newly established, semi-automated method utilises the EasyMAG device combined with pre-processing steps comprising human cell lysis, centrifugation and bacterial pellet resuspension. Quality of DNA was assessed by a universal PCR targeting the 16S rRNA gene and subsequent microarray hybridisation. The DNA extractions were amplified using two different PCR-mastermixes, to allow comparison of a commercial mastermix with a guaranteed bacterial DNA free PCR mastermix. The modified semi-automated EasyMAG protocol and the Looxster kit gave the most sensitive results. After hybridisation a detection limit of 10(1) to 10(2) bacterial cells per mL whole blood was achieved depending on the isolation method and microbial species lysed. Human DNA present in the isolated DNA suspension did not interfere with PCR and did not lead to non-specific hybridisation events. (C) 2011 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:206 / 213
页数:8
相关论文
共 50 条
  • [21] The Israel DNA database-The establishment of a rapid, semi-automated analysis system
    Zamir, Ashira
    Dell'Ariccia-Carmon, Aviva
    Zaken, Neomi
    Oz, Carla
    FORENSIC SCIENCE INTERNATIONAL-GENETICS, 2012, 6 (02) : 286 - 289
  • [22] RNA isolation from formalin-fixed paraffin-embedded material: A comparison of five commercially available RNA isolation kits
    Boeckx, Carolien
    Wouters, An
    Vanessa, Deschoolmeester
    Specenier, Pol
    Pauwels, Patrick
    Peeters, Marc
    Pauwels, Bea
    Baay, Marc
    Lardon, Filip
    CANCER RESEARCH, 2011, 71
  • [23] Production and Semi-Automated Processing of 89Zr Using a Commercially Available TRASIS MiniAiO Module
    Gaja, Vijay
    Cawthray, Jacqueline
    Geyer, Clarence R.
    Fonge, Humphrey
    MOLECULES, 2020, 25 (11):
  • [24] Expression Analysis on Archival Material: Comparison of 5 Commercially Available RNA Isolation Kits for FFPE Material
    Boeckx, Carolien
    Wouters, An
    Pauwels, Bea
    Deschoolmeester, Vanessa
    Specenier, Pol
    Lukaszuk, Krzysztof
    Vermorken, Jan B.
    Pauwels, Patrick
    Peeters, Marc
    Lardon, Filip
    Baay, Marc F. D.
    DIAGNOSTIC MOLECULAR PATHOLOGY, 2011, 20 (04) : 203 - 211
  • [25] Clinical studies on IMx® Sirolimus, a semi-automated whole blood assay.
    Blonski, DR
    Brate, E
    Bergmann, M
    Luczkiw, J
    McMahon, K
    Matuszewski, K
    Schock, G
    Weigand, RA
    CLINICAL CHEMISTRY, 1998, 44 : A92 - A92
  • [26] Comparison of eight commercially available kits for DNA extraction from formalin-fixed paraffin-embedded tissues
    Janecka, Anna
    Adamczyk, Agnieszka
    Gasinska, Anna
    ANALYTICAL BIOCHEMISTRY, 2015, 476 : 8 - 10
  • [27] Evaluation of the potential of antipsychotic agents to induce catalepsy in rats: Assessment of a new, commercially available, semi-automated instrument
    Bricker, Barbara
    Sampson, Dinithia
    Ablordeppey, Seth Y.
    PHARMACOLOGY BIOCHEMISTRY AND BEHAVIOR, 2014, 120 : 109 - 116
  • [28] Comparison of Pathogen DNA Isolation Methods from Large Volumes of Whole Blood to Improve Molecular Diagnosis of Bloodstream Infections
    Loonen, Anne J. M.
    Bos, Martine P.
    van Meerbergen, Bart
    Neerken, Sigi
    Catsburg, Arnold
    Dobbelaer, Irene
    Penterman, Roel
    Maertens, Geert
    van de Wiel, Paul
    Savelkoul, Paul
    van den Brule, Adriaan J. C.
    PLOS ONE, 2013, 8 (08):
  • [29] A semi-automated protocol for Archaea DNA extraction from stools
    Khelaifia S.
    Ramonet P.-Y.
    Bedotto Buffet M.
    Drancourt M.
    BMC Research Notes, 6 (1)
  • [30] Comparison of Four Commercially Available Whole-Genome Amplification Commercial Kits for Next-Generation Sequencing
    Park, Y.
    Shin, S.
    Park, M.
    Lee, H.
    Won, D.
    Lee, S.
    Choi, J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2023, 25 (11): : S26 - S26