On-the-fly rapid immunoassay for neonatal sepsis diagnosis: C-reactive protein accurate determination using magnetic graphene-based micromotors

被引:49
|
作者
Molinero-Fernandez, Agueda [1 ]
Arruza, Luis [2 ]
Angel Lopez, Miguel [1 ,3 ]
Escarpa, Alberto [1 ,3 ]
机构
[1] Univ Alcala, Dept Analyt Chem Phys Chem & Chem Engn, Ctra Madrid Barcelona,Km 33-600, Madrid 28871, Spain
[2] San Carlos Clin Hosp, IdISSC, Child & Teenager Inst, Div Neonatol, Madrid, Spain
[3] Univ Alcala, Chem Res Inst Andres M Del Rio, Madrid, Spain
来源
BIOSENSORS & BIOELECTRONICS | 2020年 / 158卷 / 158期
关键词
C-reactive protein; Sepsis; Carbon nanomaterials; Electrochemical detection; Micromotors; On-the-fly immunoassay; CATALYTIC MICROMOTORS; CRP; NANOPARTICLES; NANOMATERIALS; BIOSENSOR; CAPTURE; SENSOR;
D O I
10.1016/j.bios.2020.112156
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Based on the exceptional and new opened biosensing possibilities of self-propelled micromotors, a micromotor-based immunoassay (MIm) has smartly been designed for C-reactive protein (CRP) determination in plasma of preterm infants with sepsis suspicion. The design of the micromotors involved the electrosynthesis of a carbon-based outer layer (for antibody functionalization), an intermediate Ni layer (for magnetic guidance and stopped flow operations) and PtNPs inner catalytic layer (for catalytic bubble propulsion). Micromotors biofunctionalization on the outer layer (using carbon black (CB), reduced graphene oxide (rGO) and multi-walled carbon nanotubes (MWCNTs), and biocompatible propulsion capabilities, were carefully studied. Magnetic rGO/Ni/PtNPs micromotors exhibited the most efficient and reproducible (CV = 9%) anti-CRP functionalization, controlled stopped-flow operations as well as efficient bubble propulsion (1% H2O2, 1,5% NaCh, speed 140 mu m s(-1)). Analytical performance of MIm was excellent, allowing the direct (without dilution), sensitive (LOD = 0.80 mu g/mL), and accurate CRP determination (E-r = 1%) in hardly available preterm babies' plasma samples with suspected sepsis using very low volumes (<10 mu L) and in just 5 min of on-the-fly bioassay. Overall, the results obtained allowed the fast and reliable sepsis diagnostics in preterm babies' individuals with suspected sepsis, not only proving the usefulness of the approach as its potential utilization as point-of-care device for clinical analysis but drawing new horizons in extremely low sample volumes-based diagnostics.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Salivary C-Reactive Protein as Non-Invasive Marker in Diagnosis of Neonatal Sepsis
    Omran, Ahmed
    Maaroof, Abdallah
    Saleh, Mai
    Abdelwahab, Amina
    EUROPEAN JOURNAL OF PEDIATRICS, 2017, 176 (11) : 1521 - 1522
  • [22] Detection of c-reactive protein based on immunoassay using antibody-conjugated magnetic nanoparticles
    Tsai, H. Y.
    Hsu, C. F.
    Chiu, I. W.
    Fuh, C. Bor
    ANALYTICAL CHEMISTRY, 2007, 79 (21) : 8416 - 8419
  • [23] Conventional diagnosis of C-reactive protein in serum using latex piezoelectric immunoassay
    Aizawa, H
    Kurosawa, S
    Ogawa, K
    Yoshimoto, M
    Miyake, J
    Tanaka, H
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3) : 173 - 176
  • [24] RAPID-DETERMINATION OF C-REACTIVE PROTEIN BY ENZYME-IMMUNOASSAY USING 2 MONOCLONAL-ANTIBODIES
    KAPYAHO, K
    WELIN, MG
    TANNER, P
    KARKKAINEN, T
    WEBER, T
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1989, 49 (04): : 389 - 393
  • [25] ACCURACY OF LEUKOCYTE INDEXES AND C-REACTIVE PROTEIN IN THE DIAGNOSIS OF NEONATAL SEPSIS - A CRITICAL-REVIEW
    DASILVA, O
    OHLSSON, A
    KENYON, C
    PEDIATRIC RESEARCH, 1995, 37 (04) : A290 - A290
  • [26] C-REACTIVE PROTEIN VERSUS BLOOD CULTURE AS AN EARLY INDICATOR OF SEPSIS IN THE DIAGNOSIS OF NEONATAL SEPTICAEMIA
    Choudhury, Sujit Nath
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (95): : 7046 - 7048
  • [27] Validity of procalcitonin and C-reactive protein as biomarkers in diagnosis of neonatal sepsis in a referral hospital, Kenya
    Tum, Florence Chepyegon
    Ngeranwa, Joseph J. N.
    Maiyoh, Geoffrey K.
    Onyambu, Frank G.
    ALEXANDRIA JOURNAL OF MEDICINE, 2025, 61 (01) : 60 - 66
  • [28] ACCURACY OF LEUKOCYTE INDEXES AND C-REACTIVE PROTEIN FOR DIAGNOSIS OF NEONATAL SEPSIS - A CRITICAL-REVIEW
    DASILVA, O
    OHLSSON, A
    KENYON, C
    PEDIATRIC INFECTIOUS DISEASE JOURNAL, 1995, 14 (05) : 362 - 366
  • [29] Thermophoretic immunoassay based on autodisplayed Z-domains for the diagnosis of C-reactive protein
    Lee, Ga-Yeon
    Park, Min
    Kang, Min-Jung
    Langer, Klaus
    Jose, Joachim
    Pyun, Jae-Chul
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 258 : 1131 - 1137
  • [30] Evaluation of Procalcitonin, C-Reactive Protein, and Interleukin-6 as Early Markers for Diagnosis of Neonatal Sepsis
    Morad, Emad A.
    Rabie, Rehab A.
    Almalky, Mohamed A.
    Gebriel, Manar G.
    INTERNATIONAL JOURNAL OF MICROBIOLOGY, 2020, 2020