Ethanol Biomarker Testing and Challenges Lessons Learned From a College of American Pathologists Proficiency Testing Survey

被引:2
|
作者
Snozek, Christine L. H. [1 ]
Souers, Rhona [2 ]
Dizon, Annabel [3 ]
Magnani, Barbarajean [4 ]
Krasowski, Matthew D. [5 ]
机构
[1] Mayo Clin Arizona, Dept Lab Med & Pathol, 13400 E Shea Blvd, Scottsdale, AZ 85259 USA
[2] Coll Amer Pathologists, Biostat Div, Northfield, IL USA
[3] Coll Amer Pathologists, Proficiency Testing Div, Northfield, IL USA
[4] Tufts Med Ctr, Dept Pathol & Lab Med, Boston, MA 02111 USA
[5] Univ Iowa Hosp & Clin, Dept Pathol, Iowa City, IA 52242 USA
关键词
ETHYL GLUCURONIDE; DRINKING; SULFATE; PROPYL;
D O I
10.5858/arpa.2020-0699-CP
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Context.-Clinical and forensic testing for ethanol biomarkers, including ethyl glucuronide (EtG) and ethyl sulfate (EtS), is used to discern alcohol use from abstinence. These markers can be key in major decisions, including transplant eligibility or retaining licensure after alcohol misuse. Accuracy, precision, and recognition of the implications of reporting cutoffs are all essential for correct interpretation. Objective.-To evaluate trends in testing for EtG and EtS, including how laboratories perform testing and how comparable participant results are. Design.-The study examined the College of American Pathologists ethanol biomarker proficiency testing survey from 2013 to 2019. Trends in methodology, reporting cutoffs, and participant performance were evaluated for qualitative and quantitative EtG testing and for quantitative EtS testing. Results.-There was little consensus in reporting cutoffs, which ranged from 10 to 1000 ng/mL for EtG and 10 to 1500 ng/mL for EtS. Although median EtG and EtS compared well with target concentrations, individual participants' results varied widely. For quantitative enzyme immunoassay, accuracy and precision were best in EtG challenges less than 1500 ng/mL. For EtG or EtS by mass spectrometry, overall accuracy was good over a wide concentration range, but variability between participants was high. Approximately 10% (409 of 4059) of results were unacceptable, which for mass spectrometry corresponded to more than 35% above or below the group mean. Conclusions.-Although many participants performed well, there was insufficient consensus in reporting cutoffs, and a consistent fraction of laboratories failed to achieve survey standards. Guidelines for assay performance and reporting could greatly benefit laboratories and end users. (Arch Pathol Lab Med. 2021;145:1492-1498 ; doi: 10.5858/arpa.2020-0699-CP)
引用
收藏
页码:1492 / 1498
页数:7
相关论文
共 50 条
  • [31] Results of College of American Pathologists Proficiency Testing for Highly Sensitive ALK Immunohistochemistry in Lung Adenocarcinoma
    Bellizzi, Andrew M.
    Schwartz, Robert A.
    Hornick, Jason L.
    LABORATORY INVESTIGATION, 2016, 96 : 490A - 490A
  • [32] Results of College of American Pathologists Proficiency Testing for Highly Sensitive ALK Immunohistochemistry in Lung Adenocarcinoma
    Bellizzi, Andrew M.
    Schwartz, Robert A.
    Hornick, Jason L.
    MODERN PATHOLOGY, 2016, 29 : 490A - 490A
  • [33] Lessons learned from a survey of Web Applications Testing
    Kam, Ben
    Dean, Thomas R.
    PROCEEDINGS OF THE 2009 SIXTH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY: NEW GENERATIONS, VOLS 1-3, 2009, : 125 - 130
  • [34] Therapeutic Drug Monitoring of Second- and Third-Generation Antiepileptic Drugs Insights From a College of American Pathologists Proficiency Testing Survey
    Krasowski, Matthew D.
    Long, Thomas A.
    Snozek, Christine L. H.
    Dizon, Annabel
    Magnani, Barbarajean
    Melanson, Stacy E. F.
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2021, 145 (12) : 1485 - 1491
  • [35] COLLEGE-OF-AMERICAN-PATHOLOGISTS MYCOBACTERIOLOGY-E - PROFICIENCY TESTING SURVEY - SUMMARY OF PARTICIPANT PERFORMANCE, 1979-1992
    WOODS, GL
    WITEBSKY, FG
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 1995, 119 (01) : 17 - 22
  • [36] Performance of fresh frozen serum as a proficiency testing material for human chorionic gonadotropin: Results of a College of American Pathologists survey.
    Schreiber, WE
    Endres, DB
    McDowell, GA
    Palomaki, GE
    Elin, RJ
    Klee, GG
    Wang, E
    CLINICAL CHEMISTRY, 2004, 50 (06) : A93 - A93
  • [37] Redesigned proficiency testing materials improve survey outcomes for prostate-specific antigen - A College of American Pathologists Ligand Assay Survey study
    Sokoll, LJ
    Witte, DL
    Klee, GG
    Chan, DW
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2000, 124 (11) : 1608 - 1613
  • [38] Multicenter Evaluation of Processing and Analysis of College of American Pathologists (CAP) Proficiency Testing Samples by Laboratory Automation
    Babady, N. Esther
    Bourassa, Lori
    Burnham, Carey-Ann D.
    Fisher, Mark
    McElvania, Erin
    Polage, Christopher R.
    Ribes, Julie
    JOURNAL OF CLINICAL MICROBIOLOGY, 2021, 59 (05)
  • [39] Assessment of laboratory performance with Streptococcus pneumoniae antimicrobial susceptibility testing in the United States -: A report from the College of American Pathologists Microbiology Proficiency Survey Program
    Doern, GV
    Brueggemann, AB
    Pfaller, MA
    Jones, RN
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 1999, 123 (04) : 285 - 289
  • [40] Results of College of American Pathologists PD-L1 Immunohistochemistry Proficiency Testing in Lung Adenocarcinoma
    Bellizzi, Andrew
    Wu, Yaping
    Salama, Mohamed
    Rimm, David
    LABORATORY INVESTIGATION, 2020, 100 (SUPPL 1) : 1842 - 1843