Non-contrast-enhanced magnetic resonance angiography for detecting crossing renal vessels in infants and young children: comparison with contrast-enhanced angiography and surgical findings

被引:2
|
作者
Sertorio, Fiammetta [1 ,2 ]
Wong, Michela Cing Yu [2 ,3 ]
Incarbone, Veronica [1 ,4 ]
Pistorio, Angela [5 ]
Mattioli, Girolamo [3 ]
Magnano, Gian Michele [1 ]
Damasio, Maria Beatrice [1 ]
机构
[1] Univ Genoa, IRCCS Ist Giannina Gaslini, Radiol Dept, Largo Gaslini 5, I-16147 Genoa, Italy
[2] Univ Genoa, Via Balbi 5, I-16126 Genoa, Italy
[3] IRCCS Ist Giannina Gaslini, Pediat Surg Dept, Largo Gaslini 5, I-16147 Genoa, Italy
[4] Univ Insubria, Radiol Dept, Viale Borri 57, Varese, Italy
[5] Univ Genoa, IRCCS Ist Giannina Gaslini, Epidemiol Biostat & Committees Unit, Largo Gaslini 5, I-16147 Genoa, Italy
关键词
Children; Crossing renal vessel; Hydronephrosis; Magnetic resonance angiography; Non-enhanced magnetic resonance imaging; URETEROPELVIC JUNCTION OBSTRUCTION; DENTATE NUCLEUS; PEDIATRIC HYDRONEPHROSIS; SIGNAL INTENSITY; GLOBUS-PALLIDUS; MR UROGRAPHY; GADOLINIUM; ARTERY;
D O I
10.1007/s00247-018-4252-3
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
BackgroundKnowing that ureteropelvic junction obstruction is due to a crossing renal vessel is essential in choosing the appropriate surgical treatment.ObjectiveTo evaluate the diagnostic accuracy of non-contrast magnetic resonance (MR) angiography in identifying crossing renal vessels in children younger than 4 years old with unilateral hydronephrosis.Materials and methodsA retrospective review of preoperative MR urography of children with unilateral hydronephrosis was conducted by two independent readers. The presence or absence of crossing renal vessels was identified and compared with surgical findings.ResultsTwenty-nine patients were included. The disagreement between MR angiography with and without contrast enhancement in detecting a crossing renal vessel was 8%. The disagreement between non-contrast-enhanced MR and surgical findings was 17%. The disagreement between contrast-enhanced MR angiography and surgical findings was 25%. The balanced triggered angiography without contrast enhancement had a sensitivity of 70% (95% confidence interval [CI]: 35-93%) and a specificity of 93% (95% CI: 66-100%). Contrast-enhanced MR angiography had a sensitivity of 56% (95% CI: 21-86%) and a specificity of 91%. (95% CI: 59-100%).ConclusionMR without contrast enhancement may be a reliable, valid and safe alternative to contrast-enhanced MR angiography for identifying crossing renal vessels.
引用
收藏
页码:105 / 113
页数:9
相关论文
共 50 条
  • [41] One-stop preoperative assessment of renal vessels for living donors with 3.0 T non-contrast-enhanced magnetic resonance angiography: compared with computerized tomography angiography and surgical results
    Li, Xiaotian
    Xia, Fangjie
    Chen, Lihua
    Zhang, Xiaodong
    Mo, Chunbai
    Shen, Wen
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1128):
  • [42] Contrast-enhanced MR angiography of abdominal vessels: Is there still a role for angiography?
    Vosshenrich, R
    Fischer, U
    EUROPEAN RADIOLOGY, 2002, 12 (01) : 218 - 230
  • [44] Non-contrast-enhanced magnetic resonance angiography: a reliable clinical tool for evaluating transplant renal artery stenosis
    Long Jiang Zhang
    Jin Peng
    Jiqiu Wen
    U. Joseph Schoepf
    Akos Varga-Szemes
    L. Parkwood Griffith
    Yuan Meng Yu
    Shu Min Tao
    Yan Jun Li
    Xue Feng Ni
    Jian Xu
    Dong Hong Shi
    Guang Ming Lu
    European Radiology, 2018, 28 : 4195 - 4204
  • [45] Contrast-enhanced MR angiography of abdominal vessels: Is there still a role for angiography?
    R. Vosshenrich
    U. Fischer
    European Radiology, 2002, 12 : 218 - 230
  • [46] Non-contrast-enhanced magnetic resonance angiography: a reliable clinical tool for evaluating transplant renal artery stenosis
    Zhang, Long Jiang
    Peng, Jin
    Wen, Jiqiu
    Schoepf, U. Joseph
    Varga-Szemes, Akos
    Griffith, L. Parkwood
    Yu, Yuan Meng
    Tao, Shu Min
    Li, Yan Jun
    Ni, Xue Feng
    Xu, Jian
    Shi, Dong Hong
    Lu, Guang Ming
    EUROPEAN RADIOLOGY, 2018, 28 (10) : 4195 - 4204
  • [47] Contrast-enhanced magnetic resonance angiography of peripheral vessels - Different contrast agent applications and sequence strategies: A review
    Boos, M
    Lentschig, M
    Scheffler, K
    Bongartz, GM
    Steinbrich, W
    INVESTIGATIVE RADIOLOGY, 1998, 33 (09) : 538 - 546
  • [48] Unenhanced respiratory-navigated NATIVE® TrueFISP magnetic resonance angiography in the evaluation of renal arteries: Comparison with contrast-enhanced magnetic resonance angiography
    Degirmenci, B.
    Kara, M.
    Kidir, V.
    Inal, S.
    Sezer, T.
    Umul, A.
    Orhan, H.
    Celik, A. O.
    Demirtas, H.
    Yilmaz, O.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2017, 98 (02) : 133 - 140
  • [49] A free-breathing non-contrast-enhanced pulmonary magnetic resonance angiography at 3 Tesla
    YANG JianWANG WeiWANG YarongNIU GangJIN Chenwang and WU Ed Xuekui Medical Imaging CenterFirst HospitalSchool of MedicineXianJiaotong UniversityXianShaanxi ChinaDepartment of Electrical and Electronic EngineeringTheUniversity of Hong KongHong Kong SARChinaDepartment of Diagnostic RadiologyTangdu HospitalFourthMilitary Medical UniversityXianShaanxi ChinaSchool of MedicineXian Jiaotong UniversityXianShaanxiChina
    中华医学杂志(英文版), 2009, (18) : 2111 - 2116
  • [50] Contrast-enhanced MR angiography of the craniocervical vessels: a review
    X. Leclerc
    J. Y. Gauvrit
    L. Nicol
    J. P. Pruvo
    Neuroradiology, 1999, 41 : 867 - 874