Miniaturized Reveal LINQ insertable cardiac monitoring system: First-in-human experience

被引:38
|
作者
Puererfellner, Helmut [1 ]
Sanders, Prashanthan [2 ,3 ]
Pokushalov, Evgeny [4 ]
Di Bacco, Marco [5 ]
Bergemann, Tracy [6 ]
Dekker, Lukas R. C. [7 ]
机构
[1] Elisabethinen Univ Teaching Hosp, Dept Cardiol, Linz, Austria
[2] Univ Adelaide, South Australian Hlth & Med Res Inst, Ctr Heart Rhythm Disorders, Adelaide, SA, Australia
[3] Royal Adelaide Hosp, Adelaide, SA 5000, Australia
[4] State Res Inst Circulat Pathol, Arrhythmia Dept, Novosibirsk, Russia
[5] Medtron Bakken Res Ctr BV, Maastricht, Netherlands
[6] Medtronic Inc, Minneapolis, MN USA
[7] Catharina Hosp, Dept Cardiol, Eindhoven, Netherlands
关键词
Arrhythmia; Atrial fibrillation; Syncope; Remote monitoring; ATRIAL-FIBRILLATION; RANDOMIZED ASSESSMENT; STRATEGY; SYNCOPE; STROKE; RISK;
D O I
10.1016/j.hrthm.2015.02.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The Reveal LINQ is a miniaturized insertable cardiac monitor (ICM) with wireless telemetry for remote monitoring of patients with suspected arrhythmias. OBJECTIVE The primary objective of this study was to evaluate the functionality of the Reveal LINQ system by measuring R-wave sensing and data transmission. METHODS The Reveal LINQ Usability Study was a nonrandomized, prospective, multicenter trial. The study enrolled 30 patients with any indication for an ICM. Data were collected at baseline, implantation, and 1-month follow-up visits and through daily wireless transmissions. RESULTS Thirty patients were enrolled and had a Reveal LINQ device implanted. The mean age was 55 15 years. All patients had successful implantation of the ICM in one of the recommended locations. Ease of implantation procedure was rated as easy or very easy for 90% of implantations. R-wave amplitudes were 0.584 0.325 mV at implantation and 0.596 7 0.336 mV at 1 month (P = Automatic transmissions were successful 79.5% (69.5%-86.9%) of the time. Transmission failures that caused a delay in data transfer occurred because of incomplete data reception or patients being out of range in 45% and 42% of instances, respectively. For all patients, transmission failures were followed by successful automated or manual transmission of information on a subsequent day. The devices stored 217 arrhythmic episodes during 30 days of follow-up, identified as atrial fibrillation (n = 111), asystole (n = 95), bradycardia (n = 4), fast ventricular tachycardia (n = 1), and ventricular tachycardia ( n = 6). No serious procedure- or systemrelated adverse events occurred during the 1-month follow-up period. CONCLUSION The miniaturized Reveal LINQ ICM supports arrhythmia detection and monitoring, achieving adequate sensing performance without safety issues.
引用
收藏
页码:1113 / 1119
页数:7
相关论文
共 50 条
  • [41] First Belgian experience with miniaturized leadless cardiac pacemakers (Micra Transcatheter device)
    Garweg, Christophe
    Ector, J.
    Haemers, P.
    Voros, G.
    Willems, R.
    ACTA CARDIOLOGICA, 2016, 71 (01) : 79 - 79
  • [42] Improving Visualization and Interaction During Transcatheter Ablation Using an Augmented Reality System: First-in-Human Experience
    Silva, Jennifer N.
    Southworth, Michael K.
    Dalal, Aarti
    Van Hare, George F.
    Silva, Jonathan R.
    CIRCULATION, 2017, 136
  • [43] A Novel Endovascular Robotic System for Treatment of Lower Extremity Peripheral Arterial Disease: First-in-Human Experience
    Guo, Wenying
    Song, Chao
    Bao, Junmin
    Xia, Shibo
    Zhang, Lei
    Wang, Kundong
    Li, Haiyan
    Zhu, Longtu
    Lu, Qingsheng
    JOURNAL OF ENDOVASCULAR THERAPY, 2025, 32 (01) : 18 - 28
  • [44] First-in-human experience with a novel transcatheter direct annuloplasty system for severe atrial functional mitral regurgitation
    Zhu, Zhong-Kai
    Zhao, Zhen-Gang
    Zhang, Ting-Chao
    Chen, Fei
    Wei, Xin
    Liang, Yu-Jia
    Feng, Yuan
    Chen, Mao
    EUROINTERVENTION, 2023, 19 (11) : E953 - +
  • [45] Headlight and loupe-based fluorescein detection system in brain tumor surgery: a first-in-human experience
    Zhang, Xiaoran
    Habib, Ahmed
    Jaman, Emade
    Mallela, Arka N.
    Amankulor, Nduka M.
    Zinn, Pascal O.
    JOURNAL OF NEUROSURGICAL SCIENCES, 2023, 67 (03) : 374 - 379
  • [46] Novel Device for Endoluminal Esophageal Atresia Repair: First-in-Human Experience
    Muensterer, Oliver J.
    Evans, Lauren L.
    Sterlin, Alexander
    Sahlabadi, Mohammad
    Aribindi, Vamsi
    Lindner, Andreas
    Koenig, Tatjana
    Harrison, Michael R.
    PEDIATRICS, 2021, 148 (05)
  • [47] MucoUp® as a spacer in brachytherapy for uterine cervical cancer: A first-in-human experience
    Muramoto, Yoichi
    Murakami, Naoya
    Karino, Tatsuki
    Sugimoto, Satoru
    Takatsu, Jun
    Oshima, Masaki
    Kosugi, Yasuo
    Kawamoto, Terufumi
    Hirayama, Takashi
    Fujino, Kazunari
    Terao, Yasuhisa
    Shikama, Naoto
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2023, 42
  • [48] Performance of the New BioMonitor 2-AF Insertable Cardiac Monitoring System: Can Better be Worse?
    Lacour, Philipp
    Dang, Phi Long
    Huemer, Martin
    Parwani, Abdul Shokor
    Attanasio, Philipp
    Pieske, Burkert
    Boldt, Leif-Hendrik
    Haverkamp, Wilhelm
    Blaschke, Florian
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2017, 40 (05): : 516 - 526
  • [49] First-in-Human Application of Sleeping Beauty System for Gene Therapy
    Kebriaei, Partow
    Huls, Helen
    Singh, Harjeet
    Olivares, Simon
    Figliola, Matthew J.
    Dawson, Margaret
    Jena, Bipulendu
    Jackson, Rineka
    Bosque, Doyle
    McNiece, Ian
    Rondon, Gabriela
    Hackett, Perry B.
    Shpall, Elizabeth J.
    Champlin, Richard E.
    Cooper, Laurence J. N.
    MOLECULAR THERAPY, 2013, 21 : S4 - S4
  • [50] First-in-Human (FIH) Experience with the Intravascular Ventricular Assist System iVAS a Novel Approach to Mechanical Circulatory Support
    Jeevanandam, V.
    Onsager, D.
    Song, T.
    Ota, T.
    Juricek, C.
    Lanuny, T.
    Kagan, V.
    Costantini, H.
    Sayer, G.
    Adatya, S.
    Kim, G.
    Uriel, N.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S30 - S30