Miniaturized Reveal LINQ insertable cardiac monitoring system: First-in-human experience

被引:38
|
作者
Puererfellner, Helmut [1 ]
Sanders, Prashanthan [2 ,3 ]
Pokushalov, Evgeny [4 ]
Di Bacco, Marco [5 ]
Bergemann, Tracy [6 ]
Dekker, Lukas R. C. [7 ]
机构
[1] Elisabethinen Univ Teaching Hosp, Dept Cardiol, Linz, Austria
[2] Univ Adelaide, South Australian Hlth & Med Res Inst, Ctr Heart Rhythm Disorders, Adelaide, SA, Australia
[3] Royal Adelaide Hosp, Adelaide, SA 5000, Australia
[4] State Res Inst Circulat Pathol, Arrhythmia Dept, Novosibirsk, Russia
[5] Medtron Bakken Res Ctr BV, Maastricht, Netherlands
[6] Medtronic Inc, Minneapolis, MN USA
[7] Catharina Hosp, Dept Cardiol, Eindhoven, Netherlands
关键词
Arrhythmia; Atrial fibrillation; Syncope; Remote monitoring; ATRIAL-FIBRILLATION; RANDOMIZED ASSESSMENT; STRATEGY; SYNCOPE; STROKE; RISK;
D O I
10.1016/j.hrthm.2015.02.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The Reveal LINQ is a miniaturized insertable cardiac monitor (ICM) with wireless telemetry for remote monitoring of patients with suspected arrhythmias. OBJECTIVE The primary objective of this study was to evaluate the functionality of the Reveal LINQ system by measuring R-wave sensing and data transmission. METHODS The Reveal LINQ Usability Study was a nonrandomized, prospective, multicenter trial. The study enrolled 30 patients with any indication for an ICM. Data were collected at baseline, implantation, and 1-month follow-up visits and through daily wireless transmissions. RESULTS Thirty patients were enrolled and had a Reveal LINQ device implanted. The mean age was 55 15 years. All patients had successful implantation of the ICM in one of the recommended locations. Ease of implantation procedure was rated as easy or very easy for 90% of implantations. R-wave amplitudes were 0.584 0.325 mV at implantation and 0.596 7 0.336 mV at 1 month (P = Automatic transmissions were successful 79.5% (69.5%-86.9%) of the time. Transmission failures that caused a delay in data transfer occurred because of incomplete data reception or patients being out of range in 45% and 42% of instances, respectively. For all patients, transmission failures were followed by successful automated or manual transmission of information on a subsequent day. The devices stored 217 arrhythmic episodes during 30 days of follow-up, identified as atrial fibrillation (n = 111), asystole (n = 95), bradycardia (n = 4), fast ventricular tachycardia (n = 1), and ventricular tachycardia ( n = 6). No serious procedure- or systemrelated adverse events occurred during the 1-month follow-up period. CONCLUSION The miniaturized Reveal LINQ ICM supports arrhythmia detection and monitoring, achieving adequate sensing performance without safety issues.
引用
收藏
页码:1113 / 1119
页数:7
相关论文
共 50 条
  • [1] Miniaturized reveal LINQ insertable cardiac monitoring performance in different body types
    Dekker, L. R. C.
    Sanders, P. H.
    Di Bacco, M.
    Bergemann, T. A.
    Pokushalov, E.
    Purerfellner, H.
    EUROPEAN HEART JOURNAL, 2015, 36 : 548 - 548
  • [2] THE MINIATURIZED REVEAL LINQTM INSERTABLE CARDIAC MONITORING SYSTEM: A DESCRIPTION OF THE PROCEDURE EXPERIENCE
    Puererfellner, Helmut
    Sanders, Prashanthan
    Pokushalov, Evgeny
    Di Bacco, Marco
    Bergemann, Tracy
    Dekker, Lukas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A362 - A362
  • [3] The Reveal LINQ insertable cardiac monitor
    Tomson, Todd T.
    Passman, Rod
    EXPERT REVIEW OF MEDICAL DEVICES, 2015, 12 (01) : 7 - 18
  • [5] Miniaturized reveal LINQTM insertable cardiac monitoring performance in different body types
    Puererfellner, H.
    Sanders, P.
    Norman, H. S.
    Bergemann, T. L.
    Pokushalov, E.
    EUROPEAN HEART JOURNAL, 2014, 35 : 779 - 779
  • [6] Performance of a new atrial fibrillation detection algorithm in a miniaturized insertable cardiac monitor: Results from the Reveal LINQ Usability Study
    Sanders, Prashanthan
    Purerfellner, Helmut
    Pokushalov, Evgeny
    Sarkar, Shantanu
    Di Bacco, Marco
    Maus, Barbel
    Dekker, Lukas R. C.
    HEART RHYTHM, 2016, 13 (07) : 1425 - 1430
  • [7] In-office insertion of a miniaturized insertable cardiac monitor: Results from the Reveal LINQ In-Office 2 randomized study
    Rogers, John D.
    Sanders, Prashanthan
    Piorkowski, Christopher
    Sohail, M. Rizwan
    Anand, Rishi
    Crossen, Karl
    Khairallah, Farhat S.
    Kaplon, Rachelle E.
    Stromberg, Kurt
    Kowal, Robert C.
    HEART RHYTHM, 2017, 14 (02) : 218 - 224
  • [8] A tertiary centre experience of thoracic CT and cardiac MRI scanning in the presence of a reveal LINQ insertable cardiac monitoring system: a case series review of artefact, patient safety and data preservation
    Wiles, Benedict M.
    Ilingworth, Caroline A.
    Couzins, Michael L. G.
    Roberts, Paul R.
    Harden, Stephen P.
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1086):
  • [9] IMPLANTABLE CARDIAC MONITORS (BIOMONITOR 2-AF, CONFIRM RX INSERTABLE CARDIAC MONITOR AND REVEAL LINQ INSERTABLE CARDIAC MONITORING SYSTEM) TO DETECT ATRIAL FIBRILLATION AFTER CRYPTOGENIC STROKE: A SYSTEMATIC REVIEW
    Wakefield, V
    Edwards, S. J.
    Kew, K.
    Jhita, T.
    Cain, P.
    Marceniuk, G.
    VALUE IN HEALTH, 2019, 22 : S669 - S669
  • [10] Real world clinical experience of reveal LINQ insertable cardiac monitor on detecting atrial fibrillation in patients with cryptogenic stroke
    李延辉
    ChinaMedicalAbstracts(InternalMedicine), 2019, 36 (03) : 158 - 159