Development and evaluation of physical properties for digital intra-oral radiographic system

被引:0
|
作者
Hong, S [1 ]
Kim, HJ [1 ]
Jung, HJ [1 ]
Kim, KD [1 ]
So, SG [1 ]
Kim, JH [1 ]
Yoo, HS [1 ]
机构
[1] Yonsei Univ, Coll Med, Res Inst Radiol Sci, Dept Radiol,Project Med Sci BK21, Seoul 120752, South Korea
关键词
CMOS sensor; dental digital radiographic (DDR) system; modulation transfer function (MTF);
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As a part of the development of a Dental Digital Radiographic (DDR) system using a CMOS sensor, we developed hardware and software based on graphical user interface (GUI) to acquire and display readily intra-oral images from the prototype DDR system. The aims of this study were to develop the DDR system using a CMOS sensor and evaluate the physical properties of it. Electric signals generated from the CMOS sensor were transformed to digital images through control computer equipped with USB board. The distance between the X-ray tube and the CMOS sensor was varied between 10-40 cm to be optimal image quality. To evaluate the image quality according to dose variances, phantom images (60 kVp, 7 mA) were obtained at 0.03, 0.05, 0.08, 0.10, and 0.12 sec of exposure time and signal-to-noise ratio (SNR) was calculated form the this phantom image data. Modulation transfer function (MTF) was yielded by the fourier transform of the line spread function (LSF) which was derivative of the edge spread function (ESF) of sharp edge image acquired at the exposure condition of 60 kVp and 0.56 mAs. The most compatible contrast and distinct focal point length was recorded at 20 cm. The mean intensity value of pixels was irregular, so the result of SNR didn't have meaning. The result of MTF showed that the resolution of the DDR system was approximately 6.2 fine pair per mm. Prototypic DDR system was sufficient to use in intra-oral radiography in aspect of physical property even if pre-processing was not performed. The developed DDR system could be used for clinical diagnosis with the improvement of acquisition time and resolution. The measurement of another physical factors such as detected quantum efficiency (DQE) and other method signal-to-noise ratio (SNR) should be necessary to evaluate the physical properties of DDR system.
引用
收藏
页码:1357 / 1360
页数:4
相关论文
共 50 条
  • [1] Development and evaluation of a CMOS sensor-based digital intra-oral radiographic system
    Hong, S
    Jung, H
    Kim, KD
    So, SG
    Kim, JH
    Yoo, SK
    Yoo, HS
    Kim, HJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 256 - 261
  • [2] Performance evaluation and testing of digital intra-oral radiographic systems
    Doyle, P
    Finney, L
    RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) : 313 - 317
  • [3] Alternative X-ray filters for an intra-oral digital radiographic system
    Stecke, J.
    Cruz, A. D.
    Almeida, S. M.
    Boscolo, F. N.
    DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (05) : 361 - 366
  • [4] INTRA-ORAL RADIOGRAPHIC ERRORS
    PATEL, JR
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1979, 48 (05): : 479 - 483
  • [5] DENSITOMETRIC EVALUATION OF 3 INTRA-ORAL RADIOGRAPHIC FILMS
    SEELIGER, JE
    PRINSLOO, JJ
    JOURNAL OF DENTAL RESEARCH, 1989, 68 (04) : 724 - 724
  • [6] EVALUATION OF NEW RADIOGRAPHIC SCREENS FOR INTRA-ORAL RADIOGRAPHY
    DAWOOD, FF
    MANSONHING, LR
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1979, 48 (02): : 178 - 186
  • [7] Physical properties of a photostimulable phosphor system for intra-oral radiography
    Stamatakis, HC
    Welander, U
    McDavid, WD
    DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (01) : 28 - 34
  • [8] CLINICAL APPLICATION OF A NEW INTRA-ORAL RADIOGRAPHIC SYSTEM
    LIEBERMAN, J
    WEBBER, RL
    JOURNAL OF DENTAL RESEARCH, 1976, 55 : B248 - B248
  • [9] An objective comparison of four digital intra-oral radiographic systems: sensitometric properties and resolution
    Araki, K
    Endo, A
    Okano, T
    DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (02) : 76 - 80
  • [10] Physical evaluation of a system for direct digital intra-oral radiography based on a charge-coupled device
    Yoshiura, K
    Stamatakis, HC
    Welander, U
    McDavid, WD
    Shi, XQ
    Ban, S
    Kawazu, T
    Tatsumi, M
    Kanda, S
    DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (05) : 277 - 283