The diagnostic value of contrast-enhanced 2D mammography in everyday clinical use

被引:2
|
作者
Neeter, L. M. F. H. [1 ,2 ]
Raat, H. P. J. [3 ]
Meens-Koreman, S. D. [3 ]
van Stiphout, R. S. A. [3 ]
Timmermans, S. M. E. C. [3 ]
Duvivier, K. M. [4 ]
Smidt, M. L. [1 ,5 ]
Wildberger, J. E. [2 ]
Nelemans, P. J. [6 ]
Lobbes, M. B., I [1 ,2 ,7 ]
机构
[1] Maastricht Univ, GROW Sch Oncol & Dev Biol, Maastricht, Netherlands
[2] Maastricht Univ Med Ctr, Dept Radiol & Nucl Med, POB 5800, NL-6202 AZ Maastricht, Netherlands
[3] Laurentius Hosp, Dept Med Imaging, Roermond, Netherlands
[4] Vrije Univ Amsterdam, Canc Ctr Amsterdam, Amsterdam UMC, Dept Radiol & Nucl Med, Amsterdam, Netherlands
[5] Maastricht Univ Med Ctr, Dept Surg, Maastricht, Netherlands
[6] Maastricht Univ, Dept Epidemiol, Maastricht, Netherlands
[7] Zuyderland Med Ctr, Dept Med Imaging, Sittard Geleen, Netherlands
关键词
SPECTRAL MAMMOGRAPHY; DIGITAL MAMMOGRAPHY; PERFORMANCE; MRI;
D O I
10.1038/s41598-021-01622-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Contrast-enhanced mammography (CEM) has shown to be superior to full-field digital mammography (FFDM), but current results are dominated by studies performed on systems by one vendor. Information on diagnostic accuracy of other CEM systems is limited. Therefore, we aimed to evaluate the diagnostic performance of CEM on an alternative vendor's system. We included all patients who underwent CEM in one hospital in 2019, except those with missing data or in whom CEM was used as response monitoring tool. Three experienced breast radiologists scored the low-energy images using the BI-RADS classification. Next, the complete CEM exams were scored similarly. Histopathological results or a minimum of one year follow-up were used as reference standard. Diagnostic performance and AUC were calculated and compared between low-energy images and the complete CEM examination, for all readers independently as well as combined. Breast cancer was diagnosed in 23.0% of the patients (35/152). Compared to low-energy images, overall CEM sensitivity increased from 74.3 to 87.6% (p < 0.0001), specificity from 87.8 to 94.6% (p = 0.0146). AUC increased from 0.872 to 0.957 (p = 0.0001). Performing CEM on the system tested, showed that, similar to earlier studies mainly performed on another vendor's systems, both sensitivity and specificity improved when compared to FFDM.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Contrast-Enhanced Digital Mammography
    Jochelson, Maxine
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2014, 52 (03) : 609 - +
  • [22] Contrast-enhanced spectral mammography
    Wong, Christopher Yung Yuen
    Lee, Shu Yi Sonia
    Mahmood, Rameysh Danovani
    SINGAPORE MEDICAL JOURNAL, 2024, 65 (03) : 195 - 201
  • [23] Contrast-Enhanced Digital Mammography
    Monreal, Sherri
    RADIOLOGIC TECHNOLOGY, 2018, 89 (05) : 518 - 520
  • [24] The Future of Contrast-Enhanced Mammography
    Covington, Matthew F.
    Pizzitola, Victor J.
    Lorans, Roxanne
    Pockaj, Barbara A.
    Northfelt, Donald W.
    Appleton, Catherine M.
    Patel, Bhavika K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (02) : 292 - 300
  • [25] Contrast-enhanced digital mammography
    Dromain, Clarisse
    Balleyguier, Corinne
    Adler, Ghazal
    Garbay, Jean Remi
    Delaloge, Suzette
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 69 (01) : 34 - 42
  • [26] Diagnostic accuracy of contrast-enhanced digital mammography in breast cancer detection in comparison to tomosynthesis, synthetic 2D mammography and tomosynthesis combined with ultrasound in women with dense breast
    Sudhir, Rashmi
    Sannapareddy, Kamala
    Potlapalli, Alekya
    Krishnamurthy, Pooja Boggaram
    Buddha, Suryakala
    Koppula, Veeraiah
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1118):
  • [27] Diagnostic Accuracy and Incremental Value of Contrast-Enhanced Mammography Compared With Full Field Digital Mammography in a Tertiary Cancer Care Center
    Popat, Palak
    Nandi, Venugopal Prudveesh Kumar Reddy
    Katdare, Aparna
    Haria, Purvi
    Thakur, Meenakshi
    Kulkarni, Suyash
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (09)
  • [28] Contrast-enhanced spectral mammography improves diagnostic accuracy in the symptomatic setting
    Tennant, S. L.
    James, J. J.
    Cornford, E. J.
    Chen, Y.
    Burrell, H. C.
    Hamilton, L. J.
    Girio-Fragkoulakis, C.
    CLINICAL RADIOLOGY, 2016, 71 (11) : 1148 - 1155
  • [29] Diagnostic accuracy of subjective kinetic assessment of masses in contrast-enhanced mammography in comparison with contrast-enhanced magnetic resonance imaging
    Prema Subramaniam
    Rupa Renganathan
    P. Suganya
    Adrija Mandal
    Egyptian Journal of Radiology and Nuclear Medicine, 54
  • [30] Diagnostic accuracy of subjective kinetic assessment of masses in contrast-enhanced mammography in comparison with contrast-enhanced magnetic resonance imaging
    Subramaniam, Prema
    Renganathan, Rupa
    Suganya, P.
    Mandal, Adrija
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2023, 54 (01):