The diagnostic value of contrast-enhanced 2D mammography in everyday clinical use

被引:2
|
作者
Neeter, L. M. F. H. [1 ,2 ]
Raat, H. P. J. [3 ]
Meens-Koreman, S. D. [3 ]
van Stiphout, R. S. A. [3 ]
Timmermans, S. M. E. C. [3 ]
Duvivier, K. M. [4 ]
Smidt, M. L. [1 ,5 ]
Wildberger, J. E. [2 ]
Nelemans, P. J. [6 ]
Lobbes, M. B., I [1 ,2 ,7 ]
机构
[1] Maastricht Univ, GROW Sch Oncol & Dev Biol, Maastricht, Netherlands
[2] Maastricht Univ Med Ctr, Dept Radiol & Nucl Med, POB 5800, NL-6202 AZ Maastricht, Netherlands
[3] Laurentius Hosp, Dept Med Imaging, Roermond, Netherlands
[4] Vrije Univ Amsterdam, Canc Ctr Amsterdam, Amsterdam UMC, Dept Radiol & Nucl Med, Amsterdam, Netherlands
[5] Maastricht Univ Med Ctr, Dept Surg, Maastricht, Netherlands
[6] Maastricht Univ, Dept Epidemiol, Maastricht, Netherlands
[7] Zuyderland Med Ctr, Dept Med Imaging, Sittard Geleen, Netherlands
关键词
SPECTRAL MAMMOGRAPHY; DIGITAL MAMMOGRAPHY; PERFORMANCE; MRI;
D O I
10.1038/s41598-021-01622-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Contrast-enhanced mammography (CEM) has shown to be superior to full-field digital mammography (FFDM), but current results are dominated by studies performed on systems by one vendor. Information on diagnostic accuracy of other CEM systems is limited. Therefore, we aimed to evaluate the diagnostic performance of CEM on an alternative vendor's system. We included all patients who underwent CEM in one hospital in 2019, except those with missing data or in whom CEM was used as response monitoring tool. Three experienced breast radiologists scored the low-energy images using the BI-RADS classification. Next, the complete CEM exams were scored similarly. Histopathological results or a minimum of one year follow-up were used as reference standard. Diagnostic performance and AUC were calculated and compared between low-energy images and the complete CEM examination, for all readers independently as well as combined. Breast cancer was diagnosed in 23.0% of the patients (35/152). Compared to low-energy images, overall CEM sensitivity increased from 74.3 to 87.6% (p < 0.0001), specificity from 87.8 to 94.6% (p = 0.0146). AUC increased from 0.872 to 0.957 (p = 0.0001). Performing CEM on the system tested, showed that, similar to earlier studies mainly performed on another vendor's systems, both sensitivity and specificity improved when compared to FFDM.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] The diagnostic value of contrast-enhanced 2D mammography in everyday clinical use
    L. M. F. H. Neeter
    H. P. J. Raat
    S. D. Meens-Koreman
    R. S. A. van Stiphout
    S. M. E. C. Timmermans
    K. M. Duvivier
    M. L. Smidt
    J. E. Wildberger
    P. J. Nelemans
    M. B. I. Lobbes
    Scientific Reports, 11
  • [2] Diagnostic value of contrast-enhanced mammography in the characterization of breast asymmetry
    Dawoud, Bassant Mahmoud
    Darweesh, Abdelmonem Nooman
    Hefeda, Mohamed Mohamed
    Kamal, Rasha Mohamed
    Younis, Rasha Lotfy
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2022, 53 (01):
  • [3] Diagnostic value of contrast-enhanced mammography in the characterization of breast asymmetry
    Bassant Mahmoud Dawoud
    Abdelmonem Nooman Darweesh
    Mohamed Mohamed Hefeda
    Rasha Mohamed Kamal
    Rasha Lotfy Younis
    Egyptian Journal of Radiology and Nuclear Medicine, 53
  • [4] Diagnostic value of qualitative and quantitative enhancement parameters on contrast-enhanced mammography
    Kul, Musa
    Akkaya, Selcuk
    Kul, Sibel
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2024, 30 (04): : 248 - 255
  • [5] Cancer Conspicuity on Low-energy Images of Contrast-enhanced Mammography Compared With 2D Mammography
    Konstantopoulos, Christina
    Mehta, Tejas S.
    Brook, Alexander
    Dialani, Vandana
    Mehta, Rashmi
    Fein-Zachary, Valerie
    Phillips, Jordana
    JOURNAL OF BREAST IMAGING, 2022, 4 (01) : 31 - 38
  • [6] Diagnostic Performance of Contrast-enhanced Mammography: Comparison With MRI and Mammography
    Yuzkan, Sabahattin
    Cengiz, Duygu
    Hekimsoy, Ilhan
    Okcu, Ozlem Sezgin
    Oktay, Aysenur
    JOURNAL OF BREAST IMAGING, 2021, 3 (04) : 448 - 454
  • [7] Diagnostic Value of Contrast-Enhanced Digital Mammography versus Contrast-Enhanced Magnetic Resonance Imaging for the Preoperative Evaluation of Breast Cancer
    Kim, Eun Young
    Youn, Inyoung
    Lee, Kwan Ho
    Yun, Ji-Sup
    Park, Yong Lai
    Park, Chan Heun
    Moon, Juhee
    Choi, Seon Hyeong
    Choi, Yoon Jung
    Ham, Soo-Youn
    Kook, Shin Ho
    JOURNAL OF BREAST CANCER, 2018, 21 (04) : 453 - 462
  • [8] Contrast-enhanced Mammography: Successful Clinical Experience
    Woodroof, Andrea
    APPLIED RADIOLOGY, 2015, 44 (11)
  • [9] Contrast-enhanced mammography
    Fallenberg, Eva M.
    RADIOLOGE, 2021, 61 (02): : 177 - 182
  • [10] Artefacts and diagnostic pitfalls in contrast-enhanced mammography: a pictorial review
    Wong, Y. T.
    Yang, S.
    Leong, P. W.
    Chow, D. L. Y.
    Kwok, K. Y.
    Lau, K. Y. K.
    Li, O. C. A.
    CLINICAL RADIOLOGY, 2025, 81