An in vitro testing system for wrist-worn PPG devices

被引:1
|
作者
Bodwell, Erika [1 ]
Minh Nguyen [1 ]
Fine, Jesse [1 ]
Scott, Kamryn [1 ]
McShane, Michael [1 ,2 ,3 ]
Cote, Gerard L. [1 ,2 ]
机构
[1] Texas A&M Univ, Dept Biomed Engn, College Stn, TX 77843 USA
[2] Texas A&M Univ, Ctr Remote Hlth Technol & Syst, Texas A&M Engn Expt Stn, College Stn, TX 77843 USA
[3] Texas A&M Univ, Dept Mat Sci & Engn, College Stn, TX 77843 USA
基金
美国国家科学基金会;
关键词
Photoplethysmography; Tissue Optics; Tissue Phantom; In Vitro Testing; EPIDERMAL THICKNESS;
D O I
10.1117/12.2607969
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cardiovascular disease is the leading cause of death in the United States. Thus, much work is being done to develop monitoring technologies to lessen its morbidity and mortality. A common cardiovascular sensing modality is photoplethysmography (PPG), which relates local blood volume to changes in the intensity of light reaching a photodetector after traveling through tissue. Sufficient PPG signal quality from individuals with certain physiologies/anatomies can be difficult to obtain: one such example is the absorbing effect of melanin, causing poor PPG signal from individuals with a dark skin tone. Using optical phantoms, in vitro testing systems can enable device developers to quickly explore device performance under different conditions to help ensure strong performance. Here, we propose a phantom testing system for the in vitro evaluation of PPG. A pump system flows blood phantom through a 3-layer polydimethylsiloxane (PDMS) tissue phantom (mimicking epidermis, dermis, subcutis) of the volar wrist with an inset vessel representing the radial artery. The pump changes pressure to represent pressure throughout the cardiac cycle, and a PPG sensor (660nm) is placed on the tissue phantom. The effect of skin tone is analyzed by using epidermal phantoms with different optical properties representing Fitzpatrick Skin Tone I (3% volume fraction melanosome) and Fitzpatrick Skin Tone III (15% volume fraction melanosome). It was found that the PPG sensor was able to successfully and accurately register the synthetic PPG waveform, and the PPG AC/DC ratio decreased 17.7% when comparing the 3% volume fraction melanosome phantom to the 15% volume fraction melanosome phantom.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Task-Based Continuous Authentication Using Wrist-Worn Devices
    Ali, Zaire
    Payton, Jamie
    2021 IEEE INTERNATIONAL CONFERENCE ON PERVASIVE COMPUTING AND COMMUNICATIONS WORKSHOPS AND OTHER AFFILIATED EVENTS (PERCOM WORKSHOPS), 2021, : 642 - 647
  • [22] Securing Cyber-Physical Social Interactions on Wrist-Worn Devices
    Shen, Yiran
    Du, Bowen
    Xu, Weitao
    Luo, Chengwen
    Wei, Bo
    Cui, Lizhen
    Wen, Hongkai
    ACM TRANSACTIONS ON SENSOR NETWORKS, 2020, 16 (02)
  • [23] Reliability Estimation of Heart Rate Measurement Using Wrist-Worn Devices
    Yoshikawa, Hiroki
    Hayashi, Masayuki
    Uchiyama, Akira
    Higashino, Teruo
    13TH INTERNATIONAL CONFERENCE ON MOBILE COMPUTING AND UBIQUITOUS NETWORK (ICMU2021), 2021,
  • [24] Transfer learning from ECG to PPG for improved sleep staging from wrist-worn wearables
    Li, Qiao
    Li, Qichen
    Cakmak, Ayse S.
    Da Poian, Giulia
    Bliwise, Donald L.
    Vaccarino, Viola
    Shah, Amit J.
    Clifford, Gari D.
    PHYSIOLOGICAL MEASUREMENT, 2021, 42 (04)
  • [25] Development of a wrist-worn calorie monitoring system using bluetooth
    Chika Sugimoto
    Hartaman Ariesanto
    Hiroshi Hosaka
    Ken Sasaki
    Noriyoshi Yamauchi
    Kiyoshi Itao
    Microsystem Technologies, 2005, 11 : 1028 - 1033
  • [26] Architectures for wrist-worn energy harvesting
    Rantz, R.
    Halim, M. A.
    Xue, T.
    Zhang, Q.
    Gu, L.
    Yang, K.
    Roundy, S.
    SMART MATERIALS AND STRUCTURES, 2018, 27 (04)
  • [27] Development of a wrist-worn calorie monitoring system using bluetooth
    Sugimoto, C
    Ariesanto, H
    Hosaka, H
    Sasaki, K
    Yamauchi, N
    Itao, K
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2005, 11 (8-10): : 1028 - 1033
  • [28] Wrist-worn Pervasive Gaze Interaction
    Hansen, John Paulin
    Lund, Haakon
    Biermann, Florian
    Mollehbach, Emillie
    Sztuk, Sebastian
    San Agustin, Javier
    2016 ACM SYMPOSIUM ON EYE TRACKING RESEARCH & APPLICATIONS (ETRA 2016), 2016, : 57 - 64
  • [29] A Wrist-Worn Fall Detection System using Accelerometers and Gyroscopes
    Hsieh, Shang-Lin
    Wu, Shin-Han
    Chen, Chun-Che
    Yue, Tai-Wen
    2014 IEEE 11TH INTERNATIONAL CONFERENCE ON NETWORKING, SENSING AND CONTROL (ICNSC), 2014, : 518 - 523
  • [30] Validity Of Wrist-worn Activity Trackers
    De Lucia, Bianca J.
    Lynch, Victoria E.
    Kowalczyk, Kayla M.
    Wade, Jessica M.
    Hudak, Jonathan R.
    Stannard, Alicja B.