An in vitro testing system for wrist-worn PPG devices

被引:1
|
作者
Bodwell, Erika [1 ]
Minh Nguyen [1 ]
Fine, Jesse [1 ]
Scott, Kamryn [1 ]
McShane, Michael [1 ,2 ,3 ]
Cote, Gerard L. [1 ,2 ]
机构
[1] Texas A&M Univ, Dept Biomed Engn, College Stn, TX 77843 USA
[2] Texas A&M Univ, Ctr Remote Hlth Technol & Syst, Texas A&M Engn Expt Stn, College Stn, TX 77843 USA
[3] Texas A&M Univ, Dept Mat Sci & Engn, College Stn, TX 77843 USA
基金
美国国家科学基金会;
关键词
Photoplethysmography; Tissue Optics; Tissue Phantom; In Vitro Testing; EPIDERMAL THICKNESS;
D O I
10.1117/12.2607969
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cardiovascular disease is the leading cause of death in the United States. Thus, much work is being done to develop monitoring technologies to lessen its morbidity and mortality. A common cardiovascular sensing modality is photoplethysmography (PPG), which relates local blood volume to changes in the intensity of light reaching a photodetector after traveling through tissue. Sufficient PPG signal quality from individuals with certain physiologies/anatomies can be difficult to obtain: one such example is the absorbing effect of melanin, causing poor PPG signal from individuals with a dark skin tone. Using optical phantoms, in vitro testing systems can enable device developers to quickly explore device performance under different conditions to help ensure strong performance. Here, we propose a phantom testing system for the in vitro evaluation of PPG. A pump system flows blood phantom through a 3-layer polydimethylsiloxane (PDMS) tissue phantom (mimicking epidermis, dermis, subcutis) of the volar wrist with an inset vessel representing the radial artery. The pump changes pressure to represent pressure throughout the cardiac cycle, and a PPG sensor (660nm) is placed on the tissue phantom. The effect of skin tone is analyzed by using epidermal phantoms with different optical properties representing Fitzpatrick Skin Tone I (3% volume fraction melanosome) and Fitzpatrick Skin Tone III (15% volume fraction melanosome). It was found that the PPG sensor was able to successfully and accurately register the synthetic PPG waveform, and the PPG AC/DC ratio decreased 17.7% when comparing the 3% volume fraction melanosome phantom to the 15% volume fraction melanosome phantom.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Enabling Hand Gesture Customization on Wrist-Worn Devices
    Xu, Xuhai
    Gong, Jun
    Brum, Carolina
    Liang, Lilian
    Suh, Bongsoo
    Gupta, Shivam Kumar
    Agarwal, Yash
    Lindsey, Laurence
    Kang, Runchang
    Shahsavari, Behrooz
    Tu Nguyen
    Nieto, Heriberto
    Hudson, Scott E.
    Maalouf, Charlie
    Mousavi, Jax Seyed
    Laput, Gierad
    PROCEEDINGS OF THE 2022 CHI CONFERENCE ON HUMAN FACTORS IN COMPUTING SYSTEMS (CHI' 22), 2022,
  • [2] BiometricNet: Deep Learning based Biometric Identification using Wrist-Worn PPG
    Everson, Luke
    Biswas, Dwaipayan
    Panwar, Madhuri
    Rodopoulos, Dimitrios
    Acharyya, Amit
    Kim, Chris H.
    Van Hoof, Chris
    Konijnenburg, Mario
    Van Helleputte, Nick
    2018 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2018,
  • [3] Your Heart Won't Lie: PPG-based Continuous Authentication on Wrist-worn Wearable Devices
    Zhao, Tianming
    Wang, Yan
    Liu, Jian
    Chen, Yingying
    MOBICOM'18: PROCEEDINGS OF THE 24TH ANNUAL INTERNATIONAL CONFERENCE ON MOBILE COMPUTING AND NETWORKING, 2018, : 783 - 785
  • [4] High-Accuracy Stress Detection Using Wrist-Worn PPG Sensors
    Jahanjoo, Anice
    TaheriNejad, Nima
    Aminifar, Amin
    2024 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, ISCAS 2024, 2024,
  • [5] Understanding Same-Side Interactions with Wrist-Worn Devices
    Kerber, Frederic
    Lochtefeld, Markus
    Krueger, Antonio
    McIntosh, Jess
    McNeill, Charlie
    Fraser, Mike
    PROCEEDINGS OF THE NORDICHI '16: THE 9TH NORDIC CONFERENCE ON HUMAN-COMPUTER INTERACTION - GAME CHANGING DESIGN, 2016,
  • [6] Accuracy of wrist-worn wearable devices for determining exercise intensity
    Ho, Wei-Te
    Yang, Yi-Jen
    Li, Tung-Chou
    DIGITAL HEALTH, 2022, 8
  • [7] Can Wrist-Worn Medical Devices Correctly Identify Ovulation?
    Niggli, Angela
    Rothenbuhler, Martina
    Sachs, Maike
    Leeners, Brigitte
    SENSORS, 2023, 23 (24)
  • [8] WristRotate - A Personalized Motion Gesture Delimiter for Wrist-Worn Devices
    Kerber, Frederic
    Schardt, Philipp
    Loechtefeld, Markus
    PROCEEDINGS OF THE 14TH INTERNATIONAL CONFERENCE ON MOBILE AND UBIQUITOUS MULTIMEDIA (MUM 2015), 2015, : 218 - 222
  • [9] TrueHeart: Continuous Authentication on Wrist-worn Wearables Using PPG-based Biometrics
    Zhao, Tianming
    Wang, Yan
    Liu, Jian
    Chen, Yingying
    Cheng, Jerry
    Yu, Jiadi
    IEEE INFOCOM 2020 - IEEE CONFERENCE ON COMPUTER COMMUNICATIONS, 2020, : 30 - 39
  • [10] Learning based Quality Indicator Aiding Heart Rate Estimation in Wrist-Worn PPG
    Lutin, E.
    Biswas, D.
    Simoes-Capela, N.
    Van Hoof, C.
    Van Helleputte, N.
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 7063 - 7067