Physical parameters and correction factors for ionization chambers for absolute measurement of air kerma in γ-ray fields

被引:2
|
作者
Takata, N. [1 ]
Kurosawa, T.
Begum, A.
Sugita, T.
机构
[1] AIST, NMIJ, Ionizing Radiat Sect, Tsukuba, Ibaraki 3058568, Japan
[2] BUET, Dept Phys, Dhaka 1000, Bangladesh
[3] Syst Sci Lab, Ibaraki 30917, Japan
关键词
air kerma; ionization chambers; mean mass stopping power ratio; wall correction factor; Cs-137; gamma-rays; Co-60;
D O I
10.1016/j.nima.2007.05.175
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Values of physical parameters and correction factors essential for the absolute measurement of air kerma in Cs-137 and Co-60 gamma-ray fields were obtained using an EGS5 program for spherical, cylindrical and pancake ionization chambers. The mean mass collision stopping power ratio for graphite and air, was found to vary depending on the cutoff energy of electrons employed in calculation. The ratio between the energies deposited in cavity air due to Compton electrons emitted from the air and those from the graphite wall increases as the chamber size is increased. It also increases as the gamma-ray energy is reduced and is equal to 0.09 for Cs-137 gamma-rays in a spherical ionization chamber of cavity diameter 12 cm. Correction factors for gamma-ray attenuation in chamber walls and those for the contribution of scattered gamma-rays to chamber responses were obtained separately. The wall correction factor, which is equal to the product of these two factors, is close to unity for pancake chambers. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:346 / 349
页数:4
相关论文
共 50 条
  • [21] A new approach to the determination of air kerma using primary-standard cavity ionization chambers
    Burns, DT
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (04): : 929 - 942
  • [22] MEASUREMENT OF SATURATION CORRECTION FACTORS OF THIMBLE-TYPE IONIZATION CHAMBERS IN PULSED PHOTON BEAMS
    DERIKUM, K
    ROOS, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (06): : 755 - 763
  • [23] SPECIAL IONIZATION CHAMBERS FOR ABSOLUTE MEASUREMENT OF HIGH ENERGY BREMSSTRAHLUNG INTENSITY
    KOMAR, AP
    KRUGLOV, SP
    LOPATIN, IV
    NUCLEAR INSTRUMENTS & METHODS, 1966, 42 (02): : 235 - &
  • [24] RESEARCH ON THE ABSOLUTE MEASUREMENT AND CALIBRATION METHODS OF (250-450) kV X-RAY AIR KERMA AT NIM
    Zhao, Rui
    Wu, Jin-Jie
    Xu, Yang
    Ren, Guo-Yue
    Du, Hai-Yan
    Yu, Ji-Li
    Che, Wei-Na
    RADIATION PROTECTION DOSIMETRY, 2020, 192 (04) : 444 - 452
  • [25] The Effective Point of Measurement of Farmer Ionization Chambers in Magnetic Fields
    Spindeldreier, C. K.
    Schrenk, O.
    Karger, C. P.
    Greilich, S.
    Pfaffenberger, A.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [26] Absolute measurement of air kerma in medium-energy x-rays
    Wu, Jinjie
    Yang, Yuandi
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2010, 31 (8 SUPPL.): : 152 - 156
  • [27] Angular dependence of the wall correction factor for air kerma measurements using cylindrical cavity chambers
    Kurosawa, T
    Takata, N
    Koyama, Y
    APPLIED RADIATION AND ISOTOPES, 2005, 62 (05) : 805 - 808
  • [28] Air density corrections for X-ray ionization chambers
    Taylor, LS
    Singer, G
    BUREAU OF STANDARDS JOURNAL OF RESEARCH, 1932, 8 (03): : 385 - 391
  • [29] PERTURBATION CORRECTION FACTOR OF IONIZATION CHAMBERS IN BETA-RADIATION FIELDS
    BOHM, J
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (01): : 65 - 75
  • [30] CORRECTION FACTORS APPLIED TO PLANE-PARALLEL IONIZATION CHAMBERS
    NYSTROM, H
    KARLSSON, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (02): : 311 - 322