Physical parameters and correction factors for ionization chambers for absolute measurement of air kerma in γ-ray fields

被引:2
|
作者
Takata, N. [1 ]
Kurosawa, T.
Begum, A.
Sugita, T.
机构
[1] AIST, NMIJ, Ionizing Radiat Sect, Tsukuba, Ibaraki 3058568, Japan
[2] BUET, Dept Phys, Dhaka 1000, Bangladesh
[3] Syst Sci Lab, Ibaraki 30917, Japan
关键词
air kerma; ionization chambers; mean mass stopping power ratio; wall correction factor; Cs-137; gamma-rays; Co-60;
D O I
10.1016/j.nima.2007.05.175
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Values of physical parameters and correction factors essential for the absolute measurement of air kerma in Cs-137 and Co-60 gamma-ray fields were obtained using an EGS5 program for spherical, cylindrical and pancake ionization chambers. The mean mass collision stopping power ratio for graphite and air, was found to vary depending on the cutoff energy of electrons employed in calculation. The ratio between the energies deposited in cavity air due to Compton electrons emitted from the air and those from the graphite wall increases as the chamber size is increased. It also increases as the gamma-ray energy is reduced and is equal to 0.09 for Cs-137 gamma-rays in a spherical ionization chamber of cavity diameter 12 cm. Correction factors for gamma-ray attenuation in chamber walls and those for the contribution of scattered gamma-rays to chamber responses were obtained separately. The wall correction factor, which is equal to the product of these two factors, is close to unity for pancake chambers. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:346 / 349
页数:4
相关论文
共 50 条
  • [1] Calibration of ionization chambers in air kerma length
    Bochud, FO
    Grecescu, M
    Valley, JF
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (09): : 2477 - 2487
  • [2] Calibration factors for ionization chambers used for reference air kerma rate determination
    Azario, L
    Piermattei, A
    Delle Canne, S
    Mainegra, E
    Capote, R
    PHYSICA MEDICA, 1998, 14 (01) : 25 - 31
  • [3] Absolute measurement of air kerma by graphite pancake ionization chamber exposed to 60Co gamma ray
    Li, Tao
    Wang, Kun
    Yang, Xiao-Yuan
    Fan, Tie-Shuan
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2015, 49 (07): : 1153 - 1158
  • [4] Air kerma calibration factors and chamber correction values for PTW soft x-ray, NACP and Roos ionization chambers at very low x-ray energies
    Ipe, NE
    Rosser, KE
    Moretti, CJ
    Manning, JW
    Palmer, MJ
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (08): : 2107 - 2117
  • [5] Determinations of the correction factors for small fields in cylindrical ionization chambers based on measurement and numerical calculation
    Kwangwoo Park
    Wonhoon Choi
    Sungho Park
    Jin Hwa Choi
    Suk Won Park
    Jino Bak
    Journal of the Korean Physical Society, 2015, 67 : 57 - 62
  • [6] Determinations of the Correction Factors for Small Fields in Cylindrical Ionization Chambers Based on Measurement and Numerical Calculation
    Park, Kwangwoo
    Choi, Wonhoon
    Park, Sungho
    Choi, Jin Hwa
    Park, Suk Won
    Bak, Jino
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 57 - 62
  • [7] Air-kerma length calibration of CT ionization chambers
    Jensen, A.
    DeWerd, L.
    Micka, J.
    Davis, S.
    Culberson, W.
    MEDICAL PHYSICS, 2006, 33 (06) : 2006 - 2006
  • [8] Perturbation correction factors of ionization chambers in small photon fields in the magnetic field
    Tekin, T.
    Blum, I.
    Delfs, B.
    Poppe, B.
    Looe, H. K.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1357 - S1358
  • [9] The Measurement of the Air-Kerma Rate in Air and a Solid Phantom with Ionization Chambers for a 192Ir HDR Brachytherapy Source
    Zeng, Jing
    Qu, Pengpeng
    Pang, Qingsong
    Wang, Ping
    CANCER MANAGEMENT AND RESEARCH, 2020, 12 : 10821 - 10828
  • [10] ABSOLUTE CALIBRATION OF X-RAY IONIZATION CHAMBERS
    MEEKINS, JF
    UNZICKER, AE
    DERE, KP
    KREPLIN, RW
    REPORT OF NRL PROGRESS, 1974, (JUN): : 57 - 58